• 제목/요약/키워드: Oriental Diagnostic Apparatus

검색결과 16건 처리시간 0.019초

기능성 소화불량증 환자의 피로도와 기혈수 변증의 상관성 분석 (Correlation Study between Fetigue Degree and Comprehensive Diagnosis of Qui Xui Shui in Patients with Functional Dyspepsia)

  • 김현경;이준석;엄국현;이선령;김소연;허원영;김진성;류봉하;윤상협
    • 대한한방내과학회지
    • /
    • 제27권2호
    • /
    • pp.510-520
    • /
    • 2006
  • Objectives: The aim of this study was to investigate the correlation between fatigue degree and Comprehensive diagnosis of Qui Xui Shui in patients with functional dyspepsia. There again, we investigated an association between scores obtained from Comprehensive diagnosis of Qui Xui Shui and state of skin sympathetic tone or cardiovascular reactivity. Methods: Subjects were 56 patients with Functional dyspepsia and 8 healthy People. Fatigue degree was assessed by questionnaires consisting of subjective complaints of fatigue. Comprehensive diagnoais of Qui Xue Shui was investigated by questionnaire and physical examination, total score and composition score were calculated from the symptom score. Skin sympathetic tone was measured by Ryodoraku Score(RS) and Cardiovascular Reactivity(CV Reactivity) was checked by Pulse diagnostic apparatus. All patients were divided into two groups by RS $40{\mu}A$(below and above) or by CV Reactivity(decreased and increased or not decreased). Results: There was highly significant correlation between Fatigue Degree and total score and each composition score of Comprehensive diagnosis of Qui Xui Shui. And total score of patients was significantly higher than that of health controls : in the patients, females than males. Significance related with the level of RS $40{\mu}Aor$ the state of CV Reactivity were not remarkable in both patients and health control group. Conclusions: Fatigue degree seems to have a special feature reflecting the state of Comprehensive Diagnosis of Qui Xui Shui in patients with functional dyspepsia.

  • PDF

홀소자를 이용한 손목착용 맥진기의 혈압추정 알고리즘 (Estimated Blood Pressure Algorithm of Wrist Wearable Pulsimeter Using by Hall Device)

  • 안명천;최종구;손일호;이상석;김근호
    • 한국자기학회지
    • /
    • 제20권3호
    • /
    • pp.106-113
    • /
    • 2010
  • 비가압 상태에서 혈압 및 맥박을 정확하게 측정한 값를 얻기 위하여 안정시 휴대성과 소형화가 가능한 자성 홀소자를 이용한 손목 착용형 맥진기의 시제품을 개발하였다. 본 시제품을 이용하여 맥진파를 분석한 13명의 임상시험 데이터로 상관인자를 정하여 혈압추정 알고리즘의 회귀식을 구하였다. 5초간 비가압 맥진기로 맥진파를 수집한 혈압추정값과 전자혈압계나 수은혈압계로 측정한 혈압값을 비교하였다. 비가압 맥진기로 추정한 최고혈압과 최저혈압의 표준편차는 혈압국제규격 허용치 범위 안에 있는 12.1과 5.9로 각각 나타났다.

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.

한방소아과 설문지 및 검사에 관한 임상현황연구 (Clinical Investigation of Survey and Test in Korean Oriental Pediatrics)

  • 황영준;김기봉;민상연;김장현
    • 대한한방소아과학회지
    • /
    • 제22권1호
    • /
    • pp.25-34
    • /
    • 2008
  • Objectives The purpose of this study is to investigate whether Korean oriental pediatrics hospitals are using their feedback surveys to improve their medical conditions. Methods We selected 24 oriental medicine university hospitals and sent surveys to investigate. 15 of those surveys were analyzed. Results The results were classified as follows; Only 9 of university hospital said that they are currently using their feedback surveys to improve their services. Question for asking the purpose of doing their feedback surveys, 58.3% of hospital responded to get some information for diagnosis, 25% of them said to see the progress of treatment of specific disease, and 16.7% answered for using their data to the further studies. The question about the reason why hospital were need to make these feedback surveys, 46.2% of them answered to apply better service, 38.4% of them said to post medical journal. The question for asking what do oriental medical hospitals check from feedback surveys, 40% of them said they check Ryodoraku, 33.3% was pulse diagnostic apparatus, EAV(Electro-puncture According to Voll) was 26.7%. The classification according to purpose of test resulted as follows; information for diagnosis was 48.1%, the progress of a disease was 37.3%. In addition oriental medical test there were blood test, radiological test, brain waves test, Hair Tissue Mineral Analysis(HTMA), ultrasonic test, body composition analysis. Conclusions Further clinical research is necessary for improvement of using the feedback survey effectively.

  • PDF

Nasal Breath in the Lateral Position for Sleep Apnea: a Retrospective Case Series

  • Kim, Ho-Sun;Kim, Tae-Hun
    • 대한한의학회지
    • /
    • 제35권2호
    • /
    • pp.12-18
    • /
    • 2014
  • Objectives: This was a retrospective case series about the clinical effect of integrated approach with behavior therapy for obstructive sleep apnea (OSA). Methods: Medical records of twelve patients with OSA who were treated with behavior modification including nasal breathing with oral appliances and sleep in lateral position, oral administration of herbal medicines and acupuncture treatment between January and September of 2013 were reviewed. Apnea-hypopnea index (AHI), day time sleepiness, apneas and hypopneas counts during sleep, risk indicator (RI), oxygen desaturation index, average saturation during sleep, lowest desaturation, lowest saturation, snoring events ratio and number of desaturations (%) were assessed before and after treatments with the ApneaLink device, which is a portable diagnostic apparatus for monitoring airflows of the patient's breath at home. Results: After an average 62.67 (SD 37.16) days of treatment, AHI (from 17.67, 12.79 to 8.75, 8.25, p=0.007), RI (from 22.00, 13.26 to 12.09, 8.03, p=0.004), oxygen desaturation index (from 17.33, 12.17 to 8.17, 7.86, p=0.005), and number of desaturations (from 7.00 times, 9.79 to 0.92 times, 1.39, p=0.044) showed significant improvement. Daytime sleepiness improved from 6.5 (3.2) to 3.8 (1.8) but there was no significant difference after treatment (p=0.17). No adverse events related to treatment were observed during participation in the treatment. Conclusion: From this case series, we found that behavior modification with herbal medication and acupuncture may be effective for improving sleep apnea without serious adverse events. Future randomized controlled trials with larger sample size will be necessary for concrete evidence on the benefit of this integrated treatment for OSA.

적외선 체열 영상의 표준화 연구 부위별 대표 혈위를 중심으로 (Standardization Study of Thermal Imaging using the Acupoints in Human Body)

  • 최영곤;임청산;권기록
    • 대한약침학회지
    • /
    • 제11권3호
    • /
    • pp.113-122
    • /
    • 2008
  • Objective: The purpose of this study was to invigorate the use of infrared thermal imaging apparatus as a diagnostic tool in Oriental medicine by providing standard temperature on specific acupoints. Methods: Subjects for the study was recruited through an advertisement in the school homepage(www.sangji.ac.kr) explaining the objectives and methods. 100 volunteers agreeing to terms were selected and measured the full body thermal image. Common acupoints used in the clinical surrounding were chosen and final 63 acupoints were selected for the measurement. Male/female and right/left readings were obtained for the analysis. Results: Following results were obtained from analyzing the body temperature of 50 male subjects and 50 female subjects 1. Subjects participating in the study ranged from 19 years of age to 44 years. Median male age at $26.86{\pm}6.02$ and female age at $22.88{\pm}2.74$, respectively. 2. For all acupoints, no significant differences were witnessed between the gender and right, left side of the body. 3. 10 acupoints from the facial region(18 bilateral), 8 acupoints from the chest/abdomen region(10 bilateral), 6 acupoints from the back region(11 bilateral), 17 acupoints from the upper extremity(34 bilateral), and 22 acupoints from the lower extremity(44 bilateral) were chosen. 4. In the facial region, BL2 showed the highest temperature and GV26 showed the lowest. 5. In the chest/abdomen region, CV22 showed the highest temperature and CV6 showed the lowest. 6. In the back region, GV14 showed the highest temperature and BL23 showed the lowest. 7. In the upper extremity region, jianqian(extra point) showed the highest temperature and baxie(extra point) showed the lowest. 8. In the lower extremity region, KI1 and bafeng(extra point) shoed the highest temperature and BL40 showed the lowest. Conclusions: Based on the standard body temperature measured on specific acupoints throughout the body, we hope these findings can trigger further studies on applications of infrared thermal imaging and clinical usage in the field of oriental medicine.