• Title/Summary/Keyword: Oriental Diagnostic Apparatus

Search Result 16, Processing Time 0.025 seconds

Embodiment of Spatially Arterial Pulse Diagnostic Apparatus using Array Multiple Hall Devices

  • Lee, Sang-Suk;Kim, Gi-Wang;Ahn, Myung-Cheon;Park, Young-Seok;Choi, Jong-Gu;Choi, Sang-Dae;Park, Dal-Ho;Hwang, Do-Guwn;Yoon, Hyung-Rho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.721-726
    • /
    • 2007
  • The study relates to achievement and analysis of 3-dimensional spatial pulse wave archived by a spatially arterial pulse diagnostic apparatus (SAPDA), wherein a pulse sensing part array consists of multiple hall devices and is located over a skin contacting part which consists of a magnetic material. When a radially arterial pulse is transferred to the magnetic material, which is contacted skin that results in changes in a magnetic field of the lower part of the pulse sensing part array, the changes in a magnetic field can be detected by the commercial Hall semiconductor device of the pulse sensing part array. Finally, according to development of SAPDA, the 3-dimensionally arterial pulse waveform can be measured noninvasively by detecting the changes of the magnetic field.

Oriental Pulse Diagnostic Apparatus with an emphasis on sense on fingers (수지부 감각정보에 중점을 둔 한의학적 전자 맥진 시스템에 대한 고찰)

  • Kim, Byoung-Chul;Chae, Han
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.112-120
    • /
    • 2008
  • This study aims to develop a system for diagnosing pulse and disease conditions based on oriental medical classics to collect objective quantitative information in the traditional pulse examination environment that uses fingers. For this purpose, the study suggested a thimble-type sensor unit as the most appropriate pulse analyzer and proposed a traditional method to measure the pulse pressure wave on the spots of cheok, gwan and chon by installing the pulse analyzer on the forefinger, middle finger and medical finger. Then, it was interpretively found that this pulse analyzer enables us to objectively recognize 28 pulses defined in Oriental medical classics including the yukjo pulse, described as the buchimjisak-heosil pulse, and the hong, yoo, hyeok and san pulses. Finally, the study proposed a method to extract key parameters essential to pulse condition diagnosis from the pulse pressure wave measured by this pulse analyzer.

  • PDF

A clinical study of atopic dermatitis patients as measured by Pulse diagnostic apparatus (맥진기(脈診器)를 이용한 아토피 피부염 환자의 임상적 고찰)

  • Shin, Yoon-Jin;Kim, Yoon-Bum;Yoon, Sang-Heub
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2008
  • Objective : The quantification of pulse diagnosis is an important subject utilizing as a modernization of Oriental medical diagnosis and as a basic data for collaborative access between East and West Medicine. This study was to observe the tendency of pulse diagnosis in atopic dermatitis patients as measured by pulse diagnostic apparatus. Methods : We did pulse diagnostic test about 11 new outpatients who had visited the department of ophthalmology, otolaryngology, dermatology in Kyunghee oriental medical center from March 1, 2007 to October 31, 2007 and had atopic dermatitis. Results : The results were as follows. 1. Among the 11 outpatients, the total number of male patients were 5 and female patients were 6, and the age distribution, the most frequently visited age groups were 10-19 years old and 20-29 years old(each 4 patients). 2. The most common period of onset to first examination were 3 years${\leq}$ (7 patients). 3. There were 8 patients who had emphasized T-wave. 4. There were 7 patients who had repeated pulse wave pattern. Conclusion : In 11 cases who had atopic dermatitis, 8 patients had emphasized T-wave and 7 patients had repeated pulse wave pattern.

  • PDF

Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices (다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구)

  • Choi, S.D.;Kim, M.S.;Ahn, M.C.;Choi, Y.G.;Kim, G.W.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.216-220
    • /
    • 2006
  • The electric signals for the voltage as a function of distance between Hall devices and permanent magnets over the radial artery were investigated. The electric sgnals, that means signals of arterial pulse wave, were differentiated by the hardware of circuits and then were changed to differential signals as magnetic field. The 3-D images simulated by the software as function fo the intensity of differential signals were achieved. It shows that these system can apply to pulse diagnostic apparatus of porthble type medical instrument.

Simulation Analysis of Spatially Arterial Pulse Wave using Two-dimensional Array Sensors with Magnetoresistive Device (2차원 배열 자기저항소자를 이용한 공간 맥진파형의 전산모사 분석)

  • Kim, M.S.;Kim, S.W.;Kim, G.W.;Lee, S.J.;Lee, S.G.;Lee, H.S.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.307-310
    • /
    • 2005
  • To get the spatial feature of arterial pulse, we designed spatial pulse diagnostic apparatus (SPDA) using a 2-dimensional magnetoresistive sensor array. The magnetic field distribution fur magnet may was simulated using finite element method. We recognized that the field distribution of parallel magnet mays was more sensitive and uniformed than that of perpendicular one. Also the spatial displacements of magnet array were agreed with the output signal of magnetic tunnel junction (MTJ) sensor array.

A Study of Korean's Face by Sasang Diagnosis Using Questionnaire and 3D AFRA(Automatic Face Recognition Apparatus) in Middle Aged Women (한국인의 한방 체질진단 중 용모에 관한 연구, 20-48세 여자중심으로)

  • Yoo, Jung-Hee;Kwon, Jin-Hyeok;Lee, Eui-Ju;Kim, Jong-Won;Shin, Hyeon-Sang;Park, Byung-Ju;Lee, Ji-Won;Lee, Jun-Hee;Kho, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.23 no.2
    • /
    • pp.194-207
    • /
    • 2011
  • 1. Objectives: This study is about a development of Sasang constitutional classification algorithm using facial information. 2. Methods: We analysed the datum of middle aged (20~48) women collected by multi-center researchers in 2007. And this study analysed the data of the measurement of the face by 3D-AFRA (3-Dimensional Automatic Face Recognition Apparatus) and the items of impression by SDQ. We used multiple comparison, exploratory discriminant analysis and clinical decision to select optimal 3D facial variables which will be input in discriminant analysis model. And we used univariate F values and stepwise discriminant function analysis to choose best impression variables. 3. Results and Conclusions: In this study, derived discriminant function's explanation power was 39% in female group. Diagnostic accuracy rate was 66.0% in female group. And in test sample, Sasang constitutional diagnostic accuracy rate was 56.9%. In this process we could help improve the objectification of Sasang constitution diagnosis.

Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

  • Lee, Sang-Suk;Choi, Jong-Gu;Son, Il-Ho;Kim, Keun-Ho;Nam, Dong-Hyun;Hong, You-Sik;Lee, Woo-Beom;Hwang, Do-Guwn;Rhee, Jang-Roh
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.449-452
    • /
    • 2011
  • A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus.

The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance (다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의)

  • Park, Y.B.;Lee, H.J.;Huh, W
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Research on the Development of the Oriental Medical Model on the Health Examination in the Industry (산업장 건강검진의 한의학적 모델 개발 연구)

  • Chong M.S.;Kim S.C.;Lee E.K.;Chun E.J.;Han J.M.;Lee S.K.;Kang S.H.;Yu T.S.;Jeung J.Y.;Song Y.S.;Lee K.N.
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.32-50
    • /
    • 2000
  • On the process of research in the plan on oriental medical participation in the industrial health sponsored by BK21 project, we carried out the oriental medical health examination program for workers during former half-year We reached the conclusion as follows, 1. The oriental medical health examination program is contents and formalities that should be determined by present industrial health system, based on the oriental medical system and scholastic character, and included probability of the western and oriental medical cooperation. 2. The oriental medical health examination program can promote capability of individual health management and productive power of workers, and it is capable to manage on the self-conscious symptoms and macroschophically approach to their environment 3. The oriental medical health examination program that we have developed, is flow as questionare, understanding of working environment, information of result and later management. It is composed of three fields as follow , first, use of pulse diagnostic apparatus, understanding of the health promotion life style, and diagnosis of the oriental medical doctor, second, analysis of constitution, third, photographing for understanding of the musculoskeletal disorders, questionare for musculoskeletal self-conscious symptoms, and diagnosis of oriental medical doctor. 4. The oriental medical health examination program that we have developed, progressive from the view point of health, makes the oriental medical doctor's roll more important. It is the first trial at the western and oriental medical cooperation and characterized by excellence about musouloskeletal disorders. But it need to be improved in aspects of time and specialist on the health examination, diagnostic apparatus, control of examinant and later management. So we think that it needs research on the employment of health examination specialist, establishment of later management system, development of significantly diagnosable standard and assessable form on the health examination, and contents of health examination on the western and oriental medical cooperation.

  • PDF

Association of Skin Sympathetic Tone or Cardiovascular Reactivity on the Fatigue Index in Patients with Functional Dyspepsia (기능성 소화불량증 환자의 피로도에 대한 체표 교감신경 활성 및 심혈관 반응의 연계성 (양도락과 맥진검사의 진단적 가치))

  • Kim, Hyun-Kyung;Ryu, Jong-Min;Jang, Sun-Young;Lee, Joon-Suk;Eom, Guk-Hyeon;Lee, Seon-Young;Kim, Jin-Sung;Ryu, Bong-Ha;Ryu, Ki-Won;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.2
    • /
    • pp.390-397
    • /
    • 2005
  • Background & Object: The aim of this study was to investigate the association of degree of fatigue and gastric motility, measured by EGG, with skin sympathetic tone or cardiovascular reactivity in patients with functional dyspepsia. Methods: Subjects were 56 patients with Functional dyspepsia and eight healthy people. Degree of fatigue was assessed by questionnaires consisting of subjective complaints of fatigue. Skin sympathetic tone was measured by Ryodoraku Score and Cardiovascular Reactivity was checked by Pulse diagnostic apparatus. Gastric motility was estimated by EGG. First, all patients were divided into two groups by Ryodoraku Score $40{\mu}A$(below and above). Second, they were subdivided into two groups by Cardiovascular Reactivity(decreased and increased or not decreased). Estimates were made on the extent differences of degree of fatigue or state of gastric motility in each group. Results: 1. Fatigue scores was significantly higher in females and in the Ryodoraku-Score-below-$40{\mu}A$ group. It was higher in the decreased cardiovascular reactivity group than the increased group, but to no significanct extent. Also, gastric motility was better in the Ryodoraku-Score-above-$40{\mu}A$, group than in the below group. Conclusions: These results suggest that degree of fatigue and gastric motility are associated with skin sympathetic tone, but not associated with cardiovascular reactivity, and that $40{\mu}A$ is a useful cutoff point in Ryodoraku Score for assessing degree of fatigue in functional dyspepsia patients.

  • PDF