• Title/Summary/Keyword: Organophosphorus insecticide

Search Result 51, Processing Time 0.024 seconds

Organophosphorus Insecticide Residues in Fruits and Vegetables (과실 및 채소중 유기인계 잔류 농약에 관한 연구)

  • 최영진;김세원;고영수
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.2
    • /
    • pp.181-186
    • /
    • 1986
  • Organophosphorus insecticide residues were investigated in six kinds of fruits and five kinds of vegetables.The materials used in this experiment were grape, musk melon, apple, peach, plum, apricot, lettuce, green pepper, cucumber, pumpkin and tomato which were collected from June to september 1986 in Seoul. Residual pesticides investigated were Diazinon, Parathion, MEP (Fenitrothion), Malathion, EPN, MPP (Fenthion), PAP (Phenthoate) and Dimethoate and all samples were analysed by gas chromatographic technique with NPD (Nitrogen Phosphorus Detector). No sample was found to approach proposed national maximum residue limits in Korea.

  • PDF

Development of an ELISA for the Organophosphorus Insecticide Chlorpyrifos

  • Cho, Young Ae;Lee, Hye-Sung;Park, Eun-Yeong;Lee, Yong-Tae;Hammock, Bruce D.;Ahn, Ki-Chang;Lee, Jae-Koo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.481-487
    • /
    • 2002
  • A selective enzyme-linked immunosorbent assay (ELISA) for the insecticide chlorpyrifos was developed. Four haptens for chlorpyrifos were synthesized and two of them were used as immunogens after coupling to keyhole limpet hemocyanin by two differe nt approaches. Rabbits were immunized with either of them and the sera were screened against 4 haptens coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigencoated ELISA was developed, which shows an I50 of 160 ppb with a detection limit of 10 ppb. An antibody-coated ELISA was also developed, which shows an $I_{50}$ of 20 ppb with a detection limit of 0.1 ppb. The antibodies showed negligible cross-reactivity with other organophosphorus pesticides except for insecticides chlorpyrifos-methyl and bromophos-ethyl, which makes these assays suitable for the selective detection of chlorpyrifos.

A Dipstick-Type Electrochemical Immunosensor for The Detection of The Organophosphorus Insecticide Fenthion

  • Cho, Young-Ae;Cha, Geun-Sig;Lee, Yong-Tae;Lee, Hye-Sung
    • Food Science and Biotechnology
    • /
    • v.14 no.6
    • /
    • pp.743-746
    • /
    • 2005
  • A dipstick-type immunochemical biosensor for the detection of the organophosphorus insecticide fenthion was developed using a screen-printed electrode system as an amperometric transducer with polyclonal antibodies against fenthion as a bioreceptor. The assay of the biosensor involved competition between the pesticide in the sample and pesticide-glucose oxidase conjugate for binding to the antibody immobilized on the membrane. This was followed by measurement of the activity of the bound enzyme by the supply of the enzyme substrate (glucose) and amperometric determination of the enzyme reaction product ($H_2O_2$). The activity of the bound enzyme was inversely proportional to the concentration of pesticide. The optimized sensor system showed a linear response against the logarithm of the pesticide concentration ranging from $10^{-2}$ to $10^3\;{\mu}g/L$.

Development of an Enzyme-Linked Immunosorbent Assay for the Organophosphorus Insecticide Cyanophos

  • Park, Jae-Hyun;Park, Won-Chul;Kim, Yoo-Jung;Lee, Yong-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.605-609
    • /
    • 2002
  • A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of organophosphorus insecticide cyanophos. An analogue (hapten) of cyanophos was synthesized and was coupled to BSA to produce polyclonal antibodi es from rabbits. The antisera were screened against another hapten coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigen-coated ELISA was developed, which showed an I50 of 310 ng/mL with the detection limit of 20 ng/mL. The antibodies showed negligible cross-reactivities with other organophosphorus pesticides except for parathion-methyl, which makes the assay suitable for the selective detection of cyanophos.

Dimethoate Intoxication with Refractory Shock and Hyperglycemia (치료에 불응하는 지속적 저혈압과 고혈당 상태를 보인 dimethoate 중독 1례)

  • Kim, Jae-Eun;Jung, Jin-Hee;Bae, Hyun-A;Eo, Eun-Kyung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.5 no.1
    • /
    • pp.46-49
    • /
    • 2007
  • Organophosphorus insecticides induce different clinical manifestations varying according to the different side groups attached to the phosphate, their rates of degradation, and their fat solubilities. In consequence of this variation, specific treatments are required for particular organophosphorus insecticides. We report a unusual case of intoxication with dimethyl organophosphorus insecticide in a 26-year-old woman. She manifested atypical and ultimately fatal symptoms including profound shock, refractory hyperglycemia, and hypothermia.

  • PDF

Development of an ELISA for the Organophosphorus Insecticide Isofenphos

  • Park, Han-Jin;Park, Won-Chul;Jung, Tae-Owan;Rha, Choon-Sup;Lee, Yong-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.599-603
    • /
    • 2002
  • A selective enzyme-linked immunosorbent assay (ELISA) for the insecticide isofenphos was developed. Three different analogues (haptens) of isofenphos were synthesized and were coupled to carrier proteins through the pesticide thiophosphate group t o use as immunogens or coating antigens. Rabbits were immunized with one of the haptens coupled to BSA for production of polyclonal antibodies and the sera were screened against each of the other two haptens coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigen-coated ELISA was developed, which showed an I50 of 96 ng/mL with the detection limit of 2 ng/mL. The antibodies showed negligible cross-reactivity with other organophosphorus pesticides and the phenol metabolite of isofenphos, which makes the developed assay suitable for the selective detection of isofenphos. An antibody-coated ELISA was also developed, which showed an I50 of 580 ng/mL with a detection limit of 70 ng/mL.

Development of an Enzyme-Linked Immunosorbent Assay for the Organophorus Insecticide Bromophos

  • Park, Won-Cheol;Cho, Young-Ae;Kim, Yoo-Jung;Hammock, Bruce D.;Lee, Yong-Tae;Lee, Hye-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1399-1426
    • /
    • 2002
  • A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the organophosphorus insecticide bromophos. Three bromophos analogues (haptens) were synthesized and were coupled to carrier proteins to use as immunogens or coating antigens. Rabbits were immunized with either one of two haptens coupled to bovine serum albumin (BSA) for production of polyclonal antibodies, and the sera were screened against one of the haptens coupled to ovalbumin (OVA). Using the serum with highest specificity and an enzyme tracer, an antibody-coated ELISA was developed, which showed an $IC_{50}$ of 40 ng/mL with a detection limit of 7 ng/mL. The antibodies in this assay showed negligible cross-reactivity with other organophosphorus pesticides except with the insecticides chlorpyrifos and fenitrothion.

Effect of Addition of Tween 20 and Glycerol in Recombinant Escherichia Coli Culture on Organophosphorus Hydrolase (OPH) Production for Biodrgradation of Coumaphos Insecticide (Coumaphos 살충제의 생분해를 위하여 재조합 대장균 배양에서 Tween 20과 Glycerol 첨가가 유기인분해 효소 생산에 미치는 영향)

  • Choi, Suk Soon;Seo, Sang Hwan
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.501-505
    • /
    • 2007
  • Organophosphorus hydrolase (OPH) expressed from recombinant Escherichia coli was used to biodegrade organophosphate insecticide coumaphos which has a very high toxicity in mammalian cells. To improve the productivity of OPH, the effects of nonionic surfactants (Tween 20, PEG 1000) and organic solvents, such as glycerol, propanol, and ethanol, were investigated in the strain culture. The maximum OPH was produced when the 0.25% of Tween 20 and 0.5% of glycerol were added to the medium. As the OPH obtained from disrupt-cell process by ultrasound treatment was used, the biodegradation efficiencies of 0.2, 0.5, 1.0 and 2.0 mM coumaphos were 100, 88, 84 and 78%, respectively. A novel method developed in this study could be applied to the biodetoxification technology in the contaminated region with various coumaphos concentration.

Biodetoxification of Coumaphos Insecticide Using Immobilized Escherichia coli Expressing Organophosphorus Hydrolase Enzyme on Cell Surface

  • Mansee, Ayman H.;Chen, Wilfred;Mulchandani, Ashok
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.436-440
    • /
    • 2000
  • Recently, we reported an improved technology for the degradation of organophosphate nerve agents using whole cells of genetically engineered Escherichia coli that anchored and displayed the enzyme organophosphorus hydrolase on the cell surface. In this paper we report the immobilization of these cells on highly porous sintered glass beads and the subsequent application of the immobilized cell in a continuous-flow packed bed bioreactor for the biodetoxification of a widely used insecticide, coumaphos.

  • PDF

Syntheses of 3-Pyrimidyl- and 3-Pyranyl-5,6-benzocoumarin Derivatives

  • El-Deen, Ibrahim M.;Al-Wakeel, El-Sayed I.;El-Mawla, Ahmed G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.610-612
    • /
    • 2002
  • A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of organophosphorus insecticide cyanophos. An analogue (hapten) of cyanophos was synthesized and was coupled to BSA to produce polyclonal antibodi es from rabbits. The antisera were screened against another hapten coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigen-coated ELISA was developed, which showed an I50 of 310 ng/mL with the detection limit of 20 ng/mL. The antibodies showed negligible cross-reactivities with other organophosphorus pesticides except for parathion-methyl, which makes the assay suitable for the selective detection of cyanophos.