• Title/Summary/Keyword: Organic wastewater

Search Result 1,232, Processing Time 0.022 seconds

Treatment Characteristics of Paper-mill Wastewater Using Pure Oxygen Activated Sludge Process (순산소 활성오니 공정을 이용한 제지폐수의 처리특성)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.27-34
    • /
    • 1999
  • An experimental study on improvement of the paper-mill wastewater treatment using the pure oxygen activated sludge process was conducted. The effects of hydraulic retention time(HRT) and BOD loading on organic removal efficiency were investigated. The BOD removal efficiencies were above 90% under all examined HRTs except for HRT of 3 hours. The increase of HRT from 3 hours to 6 hours, and to 12 hours significantly improved BOD and COD removal efficiencies, respectively. However, additional increase of HRT did not affect organic removal efficiency. F/M ratio change at fixed HRT did not affect organic removal efficiency. However, F/M ratio investigated in this study(0.11~1.98kgBOD/kgMLVSS/day) was 5 times greater in maximum than that of conventional activated sludge process, which implies that pure oxygen activated sludge process can treat wastewater with high organic strength. Under the same HRT, the volumetric BOD loading change cause no effect on organic removal efficiency also.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater (화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구)

  • 박선구;고오석;신대윤
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

Isolation and Identification of Organic Compounds-Degrading Bacteria for the Treatment of Food Wastewater (음식물류폐수처리를 위한 유기물분해 미생물의 분리 및 동정)

  • Chung, Doo-Young;Song, In-Geun;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.128-135
    • /
    • 2007
  • Microorganisms which can degrade organic compounds such as proteins, lipids, and cellulose in food wastewater, were isolated from food wastewater, livestock wastewater, earthworm, and etc. Among these, eleven strains which showed higher degrading activities against three organic compounds, were finally isolated, characterized, and identified. Nine strains were found to be Bacillus species, and other two were to be Enterobacter sp. and Pantoea agglomerans. The strains FWB-5 (Bacillus pumilus), FWB-6 (B. lichenisformis) and OD-4 (Pantoea agglomerans), isolated from food wastewater and livestock wastewater, respectively, showed higher three enzyme activities to organic compounds, especially to cellulose, compared to other strains. The optimal growth conditions for the great enzyme activities were at $37^{\circ}C$ with pH 7.0 for FWB-5 and OD-4 strains, whereas, these were at $25^{\circ}C$ with pH 7.0 for FWB-6 strain.

  • PDF

Study of Soluble Organic Matter of Livestock Wastewater Treated by Ionized Gas and Coagulation after Ionized Gas (이온화가스와 응집공정을 조합한 축산폐수의 처리시 용존 유기물의 특성에 관한 연구)

  • Lee, Eun-Ju;Chung, Paul-Gene;Kim, Min-Jeong;Hyun, Mi-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.708-713
    • /
    • 2004
  • This study was performed to investigate the variations of hydrophilic and hydrophobic organic matter fractions in soluble organic matter according to livestock wastewater treatment by ionized gas and coagulation effect to these fractions after ionized gas contact. As a result of experiment, because of ionized gas contact, particle in the surface of livestock wastewater was more smaller and the result was consisted of particle size analysis and the amount of small size was increased. Also, we confirmed that organic matters in livestock wastewater by ionized gas contact were removed. The relation equation between ionized gas contact time(X) and $TCOD_{cr}$(Y) was shown as yscale(y)=3.748-0.431* xscale(X). That between ionized gas contact time(X) and $TCOD_{cr}$(Y) was yscale(y)=3.283-0.463* xscale(X). As respects the HPL(hydrophilic matter)and HPO(hydrophobic matter) fractions of raw in livestock wastewater treatment plant, HPL fraction was 53.2% and HPO fraction was 46.8%. But, HPO fraction according to ionized gas treatment was increased at 30min and after that time, HPL fraction was increased. Also, when we performed coagulation process after ionized gas treatment of raw wastewater, the removal efficiency of organic matter was the highest at 30min of ionized gas treatment because of the variation of HPL and HPO fractions in organic matter by ionized gas. In coagulation process following after ionized gas process, HPO was removed more effective than HPL.

The Coagulation Characteristics of Wastewater Using Poly-γ-glutamic Acid (Poly-γ-glutamic acid(PGA)를 이용한 폐수의 응집특성)

  • Kwon, Kwi-bock;Kim, Dong-ha;Kang, Seon-Hong;Sung, Moon-Hee;Park, Chung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.357-362
    • /
    • 2005
  • Poly-${\gamma}$-glutamic acid (${\gamma}-PGA$), which is extracted from fermented soybeans, is a high molecular weight, adhesive, and negatively charged(anionic) polymer. Recently, ${\gamma}-PGA$ has gained attention due to its potential as polymer. The objectives of this study were to examine the applicability of ${\gamma}-PGA$ as a coagulant and/or a coagulant aid, to evaluate the efficiency of ${\gamma}-PGA$ for the removal of Organic and Ammonium substance in wastewater treatment. The effect of coagulation was evaluated for the removal of SS and organic matter using poly aluminum chloride(PACI) as well as newly developed ${\gamma}-PGA$. The maximum COD removal rate of 63% and the SS of 78% were occurred at the dosage of 50mg/L ${\gamma}-PGA$ only. The most effective removal for particulate and organic matter was occured when both PACI and ${\gamma}-PGA$ were applied at the rate of 20:1(10mg/L PACI and 0.5mg/L ${\gamma}-PGA$). When mixed with PACI, only small portion of ${\gamma}-PGA$ was enough to improve removal efficiencies of organic and particulate matter in wastewater. This result showed the positive potential of ${\gamma}-PGA$ as a new coagulant materials for wastewater treatment.

Removal of Non-biodegradable Organic Contaminants in Wastewater from crude oil reserve base Using Pulse UV System (Pulse UV 장치를 이용한 원유비축시설 발생폐수의 난분해성 유기오염물질 제거)

  • Sohn, Jin-Sik;Park, Soon-Ho;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.861-867
    • /
    • 2011
  • Wastewater from crude oil reserve base usually contains large amount of non-biodegradable contaminants. The conventional wastewater treatment progress can hardly meet the regulation of wastewater effluent quality. This study investigated the removal of non-biodegradable organic contaminants in wastewater from crude oil reserve base using a pulse UV treatment. The modified process incorporating pulse UV process was set up to treat the wastewater from crude oil reserve base. The treatment process is composed with coagulation and flocculation, micro-bubble flotation, sand filter, pulse UV system, and GAC filter. The results show CODMn was effectively removed by the process with pulse UV system and it can meet the wastewater effluent regulation. The single effect of pulse UV process in CODMn removal was not significant(9~15% based on sand filtered effluent), however with the subsequent activated carbon filter the removal ratio CODMn was increased up to 28% compared to the process without pulse UV syetem.

Fundamental Studies on the Treatment of Particulate Organic Substances Contained in Wastewater by Flotation (부유선별법에 의한 폐수 함유 입자성 유기 물질 처리에 대한 기초 연구)

  • Yoo, Jung-Min;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.674-680
    • /
    • 2013
  • Basic studies for the treatment of particulate organic substances contained in wastewater by flotation have been conducted. Four kinds of plastics were chosen as the possibly existing organic particles in wastewater and the Zisman plots for these substances were constructed by measuring the contact angle of liquids on their surfaces. The critical surface tensions for these organic substances were estimated based on the constructed Zisman plot and the floatability of organic substances were regarded to be related with their molecular structure. The existence of dissolved organic substances such as a surfactant was observed to affect the extent of flotation of particulate organics. In addition, the consideration of work of adhesion was thought to be better than adopting the critical surface tension as the analytical basis in the operational design of flotation process of organic particles.

The Nutrient Removal of Mixed Wastewater composed of Sewage and Stable Wastewater using SBR (SBR을 이용한 하수와 우사폐수로 구성된 혼합폐수의 영양소 제거)

  • 김홍태
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.617-623
    • /
    • 1999
  • This study was carried out to obtain the optimal operating parameter on organic matters and nutrient removal of mixed wastewater which was composed of sewage and stable wastewater using SBR. A laboratory scale SBR was operated with An/Ae(Anaerobic/Aerobic) ratio of 3/3, 2/4 and 4/2(3.5/2.5) at organic loading rate of 0.14 to 0.27 kgBOD/$m^3$/d. TCOD/SCOD ratio of mixed wastewater was 3, so the important operating factor depended upon the resolving the particulate parts of wastewater. Conclusions of this study were as follows: 1) For mixed wastewater, BOD and COD removal efficiencies were 93-96% and 85-89%, respectively. It was not related to each organic loading rate, whereas depended on An/Ae ratio. During Anarobic period, the amount of SCOD consumption was very little, because ICOD in influent was converted to SCOD by hydrolysis of insoluble matter. 2) T-N removal efficiencies of mixed wastewater were 55-62% for Exp. 1, 66-76% for Exp. 2, and 67-81% for Exp. 3, respectively. It was found that nitrification rate was increased according to organic concentration in influent increased. Therefore, the nitrification rate seemed to be achieved by heterotrophs. During anoxic period, denitrification rate depended on SCOD concentration in aerobic period and thus, was not resulted by endogenous denitrification. However, the amount of denitrification during anaerobic period were 3.5-14.1 mg/cycle, and that of BOD consumed were 10-40 mg/cycle. 3) For P removal of mixed wastewater, EBPR appeared only Mode 3($3^*$). It was found that the time in which ICOD was converted to VFA should be sufficient. For mode 3 in each Exp., P removal efficiencies were 74, 87, and 81%, respectively. But for 45-48 of COD/TP ratio in influent, P concentration in effluent was over 1 mg/L. It was caused to a large amount of ICOD in influent. However, as P concnetration in influent was increased, the amounts of P release and uptake were increased linearly.

  • PDF

Analysis of COD fraction and change of COD in nitritation reactor using various wastewater (다양한 하수를 대상으로 유기물 성상과 질산화 반응조 내 유기물 변화)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • In ASM model, organic matters are classified according to their characteristics and general classification into COD and BOD cannot satisfy conditions required by ASM. In this study, it was performed to study classification of organic matters required by ASM on the basis of microorganisms' respiration rate subject to wastewater and sludge treatment. As results of analysis of the organic matter's appearance, it was found that there were some differences in composition of organic matters between wastewaters. It is considered that it is an important characteristic of wastewater that should be understood in treating wastewater in each process. Therefore, it is considered that appearance of organic matters in each wastewater identified by this study will be used as important basic data for operation of municipal wastewater treatment plant. It was identified that SS was an important factor affecting nitrification through organic matter and ammonium nitrogen change analysis according to reaction time in the nitrification. It is considered that the nitrification has close relationship with choice of optimal retention time.