• Title/Summary/Keyword: Organ at risk

Search Result 163, Processing Time 0.034 seconds

Comparison of Intensity-modulated Radiation Therapy (IMRT), Uniform Scanning Proton Therapy (USPT), and Intensity-modulated Proton Therapy (IMPT) for Prostate Cancer: A Treatment Planning Study (전립선 암 환자의 IMRT, USPT, 및 IMPT 기법에 따른 치료효과 비교)

  • Son, Kihong;Cho, Seungryong;Kim, Jin Sung;Han, Youngyih;Ju, Sang Gyu;Ahn, Sung Hwan;Shin, Eunhyuk;Shin, Jung Suk;Park, Won;Pyo, Hongryul;Choi, Doo Ho
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.154-161
    • /
    • 2013
  • This study assessed compared photon and proton treatment techniques, such as intensity modulated radiation therapy (IMRT), uniform scanning proton therapy (USPT), and intensity modulated proton therapy (IMPT), for a total of 10 prostate cancers. All treatment plans delivered 70 Gy to 95% of the planned target volume in 28 fractions. IMRT plans had 7 fields for the step and shoot technique, while USPT and IMPT plans employed two equally weighted, parallel-opposed lateral fields to deliver the prescribed dose to the planned target. Inverse planning was then incorporated to optimize IMPT. The homogeneity index (HI) and conformity index (CI) for the target and the normal tissue complication probability (NTCP) for organ at risk (OAR) were calculated. Although the mean HI and CI for target were not significantly different for each treatment techniques, the NTCP of the rectum was 2.233, 3.326, and 1.707 for IMRT, USPT, and IMPT, respectively. The NTCP of the bladder was 0.008, 0.003, and 0.002 respectively. The NTCP values at the rectum and bladder were significantly lower using IMPT. Our study shows that using proton therapy, particularly IMPT, to treat prostate cancer could be beneficial compared to 7-field IMRT with similar target coverage. Given these results, radiotherapy using protons, particularly optimized IMPT, is a worthwhile treatment option for prostate cancer.

Outcome and Prognosis in Critically III Children Receiving Continuous Renal Replacement Therapy (소아 중환자에서 지속적 신대체요법의 치료 결과와 예후)

  • Park, Kwang-Sik;Son, Ki-Young;Hwang, You-Sik;Kim, Joung-A;Cheung, Il-Chun;Shin, Jae-Il;Park, Ji-Min;Ahn, Sun-Young;Lyu, Chuhl-Joo;Lee, Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.247-254
    • /
    • 2007
  • Purpose : Continuous renal replacement therapy(CRRT) has been the first choice for the treatment of acute renal failure in critically ill children not only in western countries but also in Korea. However, there are very few studies that have analyzed the outcome and prognosis of this modality in Korean children. We performed this study to evaluate the factors associated with the outcome and prognosis of patients treated with CRRT. Methods : We retrospectively reviewed the medical records of 32 children who had received CRRT at Severance hospital from 2003 to 2006. The mean age was 7.5 years(range 4 days-16 years) and the mean body weight was 25.8 kg (range 3.2-63 kg). Results : Eleven(34.4%) of the 32 patients survived. Bone marrow transplantation and malignancy were the most common causes of death and underlying disease leading to the need for CRRT Mean patient weight, age, duration of CRRT, number of organ failures, urine output, estimated glomerular filtration rate(eGFR), C-reactive protein, and blood urea level did not differ significantly between survivors and nonsurvivors. (1) Pediatric risk of mortality(PRISM) III score at CRRT initiation($9.8{\pm}5.3$ vs. $26.7{\pm}7.6$, P<0.0001), (2) maximum pressor number ($2.1{\pm}1.2$ vs. $3.0{\pm}1.0$, P=0.038), and (3) the degree of fluid overload($5.2{\pm}6.0$ vs. $15.0{\pm}8.9$, P=0.002) were significantly lower in survivers than in nonsurvivors. Multivariate analysis revealed that fluid overload was the only independent factor reducing survival rate. Conclusion : CRRT was successfully applied to the treatment of acute renal failure in a wide range of critically ill children. To improve survival, we suggest the early initiation of CRRT to prevent the systemic worsening and progression of fluid overload in critically ill children with acute renal failure. (J Korean Soc Pediatr Nephrol 2007;11:247-254)

  • PDF

Real-Time AT-PCR for Quantitative Detection of Bovine Parainfluenza Virus Type 3 during the Manufacture of Biologics (생물의약품 제조공정에서 Bovine Parainfluenza Virus Type 3 정량 검출을 위한 Real-Time RT-PCR)

  • Lee, Dong-Hyuck;Kim, Chan-Kyong;Kim, Tae-Eun;Kim, In-Seop
    • KSBB Journal
    • /
    • v.23 no.4
    • /
    • pp.303-310
    • /
    • 2008
  • Bovine blood, cell, tissue, and organ are used as raw materials for manufacturing biologics such as biopharmaceuticals, tissue-engineered products, and cell therapy. Manufacturing processes for the biologics have the risk of viral contamination. Therefore viral validation is essential in ensuring the safety of the products. Bovine parainfluenza virus type 3 (BPIV3) is one of the common bovine pathogens and has widely been known as a contaminant of biologics. In order to establish the validation system for the BPIV3 safety of biologics, a real-time RT-PCR method was developed for quantitative detection of BPIV3 contamination in raw materials, manufacturing processes, and final products. Specific primers for amplification of BPIV3 RNA was selected, and BPIV3 RNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be 2.8 $TCID_{50}/mL$. The real-time RT-PCR method was validated to be reproducible and very specific to BPIV3. The established real-time RT-PCR assay was successfully applied to the validation of Chinese hamster ovary (CHO) cell artificially infected with BPIV3. BPIV3 RNA could be quantified in CHO cell as well as culture supernatant. Also the real-time RT-PCR assay could detect 7.8 $TCID_{50}/mL$ of BPIV3 artificially contaminated in bovine collagen. The overall results indicated that this rapid, specific, sensitive, and robust assay can be reliably used for quantitative detection of BPIV3 contamination during the manufacture of biologics.

The Role of Radiation Therapy on Local Recurrence of Rectal Cancer (직장암에서 수술후 방사선치료의 역활)

  • Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik;Kim, Young-Jin
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.205-212
    • /
    • 1992
  • Ninety five patients of rectal cancer treated with surgery with or without adjuvant radiation therapy since January 1982 to December 1990 at the Chonnam University Hospital were analysed retrospectively regarding local failure. Of these 95 patients 72 patients were treated with surgery alone and remaining 23 patients received postoperative radiation therapy to pelvis. There were 45 men and 50 women with 53 years of median age. Minimum follow-up period was 19 months and median was47 months (range, 19-125 months). Kaplan-Meier method was used to calculate actuarial risk of local recurrence and survival rate. Comparison between two groups was evaluated by Log rank test. Of total 95 patients twenty seven patients ($28.4\%$) developed local recurrence and 13 patients ($17.3\%$) developed local and distant metastasis concomitantly. Eighty nine percent (24/27) of patients developed local recurrence within 24 months. Pelvic organ adjacent to the primary tumor area was the most common site of initial local recurrence. Of 72 patients treated with surgery alone local recurrence developed in 24 patients. Of 17 patients with stage A and 81 (Gunderson-Sosin modification of Dukes' staging system) 6 patients experienced local recurrence ($31.2\%$). The local recurrence rate of B2 and B3 group was $29.9\%$ (7/33) and that of C2 and C3 was $54.7\%$ (11/19), respectively. There was statistically significant difference between two groups (p<0.05). Of 23 patients treated with definitive surgery and radiation therapy $10\%$ (1/10) recurred in B2 and B3 patients. This was slightly lower than C2 and C3 patients ($22.2\%$, 2/10) of similar policy, but revealed no statistically significant difference (p>0.05). In the patients of B2+3 local failure rate decreased when radiation therapy was added ($29.9\%$ vs $10\%$, p>0.05) and also similar results in C2+3 group ($34.7\%$ vs $22.2\%$, p<0.05). The local failure rate in relation to distance from the anal verge had no statistically significant difference.

  • PDF

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Ttrosine Hydroxylase in Japanese Medaka (Oryzias latipes): cDNA Cloning and Molecular Monitoring of TH Gene Expression As a Biomarker (송사리 Tyrosine Hydroxylase: cDNA 클로닝 및 생물지표로서의 TH 유전자 발현의 분자생물학적 추적)

  • Shin, Sung-Woo;Kim, Jung-Sang;Chon, Tae-Soo;Lee, Sung-Kyu;Koh, Sung-Cheol
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.4
    • /
    • pp.131-137
    • /
    • 2000
  • The release of hazardous waste materials into the environment poses serious risks in humans and ecosystems. The risk assessment of environmental pollutants including hazardous chemicals requires a comprehensive measurement of hazard and exposure of the chemicals that can be achieved by toxicity evaluation using a biological system such as biomarkers. In this report we have tried to develop a biomarker used to elucidate a molecular basis of, and to monitor abnormal behaviors caused by diazinon in Japanese medaka (Oryzias latipes) as a model organism. First, an attempt was made to clone tyrosine hydroxylase gene from Japanese medaka that would be a candidate for a biomarker for neuronal modulations and behaviors. For monitoring experiments at behavioral and molecular biological levels, the fish were treated under different sublethal conditions of diazinon and their behavioral responses were observed . In this study we have successfully cloned a partial TH gene from the medaka fish through PCR screening of an ovary cDNA library. DNA sequencing analysis revealed that the amplified fragment was 327 bp encoding 109 amino acids. Comparing the DNA sequence of medaka TH with other species, TH gene revealed the DNA sequence was completely identical to that of rat TH. In the RT-PCR, 330 Up of mRNA was consistently amplified in all the treated samples including control There were no significant differences in the TH expression level regardless of treating concentrations (1∼5,000 ppb) and time (0∼48 hr) The reason appeared to be that RT-PCR was not performed using through a quantitative analysis normalized against an actin gene expression. Organ or tissue - specific detection of TH activity and mRNA as biomarkers will be a useful monitoring tool for neurobehavioral changes in fish influenced by toxic chemicals. Furthermore, quantitative analysis of locomotive patterns and its correlation with the neurochemical and molecular data would be highly useful in measuring toxicity and hazard ofvarious environmental pollutants.

  • PDF

Experiences of the First 130 Patients in Gangnam Severance Hospital (강남세브란스병원 토모테라피를 이용한 치료환자의 130예 통계분석 및 경험)

  • Ha, Jin-Sook;Jeon, Mi-Jin;Kim, Sei-Joon;Kim, Jong-Dae;Shin, Dong-Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • Purpose: We are trying to analyze 130 patients' conditions by using our Helical Tomotherapy, which was installed in our center in Oct. 2007. We will be statistically approach this examination and analyze so that we will be able to figure out adaptive plans according to the change in place of the tumor, GTV (gross tumor volume), total amount of time it took, vector (${\upsilon}=\surd$x2+y2+z2) and the change in size of the tumor. Materials and Methods: Objectives were the patients who were medicated with Tomotherapy in our medical center since Oct. 2007 August 2008. The Average age of the patients were 53 years old (Minimum 25 years old, Maximum 83 years old). The parts of the body we operated were could be categorized as Head&neck (n=22), Chest (n=47), Abdomen (n=25), Pelvis (n=11), Bone (n=25). MVCT had acted on 2702 times, and also had acted on our adaptive plan toward patients who showed big difference in the size of tumor. Also, after equalizing our gained MVCT and kv-CT we checked up on the range of possible mistake, using x, y, z, roll and vector. We've also investigated on Set-up, MVCT, average time of operation and target volume. Results: Mean time on table was 22.8 minutes. Mean treatment time was 13.26 minutes. Mean correction (mm) was X=-0.7, Y=-1.4, Z=5.77, roll=0.29, vector=8.66 Head&neck patients had 2.96 mm less vector value in movement than patients of Chest, Abdomen, Bone. In increasing order, Head&neck, Bone, Abdomen, Chest, Pelvis showed the vector value in movement. Also, there were 27 patients for adaptive plan, 39 patients, who had long or multiple tumor. We could know that When medical treatment is one cure plan, it takes 32 minutes, and when medical treatment is two cure plan, it takes 40 minutes that one medical treatment takes 21 minutes, and the other medical treatment takes 19 minutes. Conclusion:With our basic tools, we could bring more accurate IMRT with MVCT. Also, through our daily image, we checked up on the change in tumor so that adaptive plan could work. It was made it possible to take the cure of long or multiple tumor, the cure in a nearby OAR, and the complicated cure that should make changes of gradient dose distribution.

  • PDF

Evaluation of Usefulness on In-vivo Diode Dosimetry for Measuring the Tumor Dose of Oral Cancer Patient (구강암 환자의 종양 선량 측정을 위한 In-vivo Diode Dosimetry의 유용성 평가)

  • Na Kyung-Su;Lee Je-Hee;Park Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2005
  • Purpose : This test is designed to identify the validity of treatment plan by implementing real-time dosimetry by means of dose that is absorbed into PTV and OAR when preparing doses of 3D and POP plans. Materials and Methods : In treatment. error can be calculated be comparing Exp. Dose with the actual dose, which has been converted from 'the reading value obtained by placing diode detector on the area to be measured'. Same test can be repeated using Alderson-Rando phantom. Results : Errors were found: A patient(POP plan): 197.6/199=-1.2%, B patient(3D-plan): 199.9/198.7=+0.6%, C patient: 196/200=-1.5%. In addition, considering the resulted value of measuring OAR besides target-dose for C patient showed 96/200, representing does of 47%, the purpose of protection was judged to be duly accomplished. Also it was acknowledged the resulted value of -3.7% met the targeted dose within the range of ${\pm}5%$. Conclusion : Aimed for identifying the usefulness of pre-treatment dose measurement using diode detector, this test was useful to evaluate the validity of curing because it resulted in the identification of category to be protected as well as t dose. Moreover, it is thought to have great advantage in ascertaining the dose of target, dose of which is not calculated yet. Similar to L-gram before treatment, this test is thought to be very effective so that it can bring great advantages in the aspects such as validity of curing method and post-treatment plan as well.

  • PDF

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.