• Title/Summary/Keyword: Order of Magnitude

Search Result 1,602, Processing Time 0.04 seconds

Analysis of Plate Motion Parameters in Southeastern South Korea using GNSS (GNSS를 활용한 한반도 동남권 지역의 지각 변동 파라미터 분석)

  • Lee, Seung Jun;Yun, Hong Sic
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.697-705
    • /
    • 2020
  • This paper deals with an analysis of crustal movement for the sourthern part of Korean peninsula using GNSS (Global Navigation Satellite System) data. An earthquake of more than 5.0 occurred in the southeastern region of the Korean Peninsula, and it is necessary to evaluate the risk of earthquakes in various ways.In order to reveal long-term tectonic movement patten in Pohang and Gyeongju provinces, we derived crustal movement parameters related with elastic theory. We used GAMIT/GLOBK for analyzing seven-year interval GNSS data of CORS (Continuously Operating Reference Stations). The azimuth of velocity vectors trended generally about 110° with an mean magnitude of 31mm/yr.The main characteristics of the strain change for seven-year in Korea obtaind from our study. Direction of the principal axis of the maximum compression is ENE-WSW as a whole, through there are some exceptions. The mean rate of the maximum shear strain change is (0.11±0.07)μ/yr, that is approximately one third that of Chubu district, Central Japan. Taking into account our results, the mean rate of maximum shear in southern part of Korean peninsula is considered as reasonable. The mean azimuth of principal strain is about (85.4°±26.8°). There are some exceptions of azimuth because the average azimuth differ from the left and right side in Yangsan fault which are about (73.2°±21.5°) and (105.2°±17.0°) respectively, It is noteworthy that the high seismicity areas in the southern part of Korea peninsula almost coincides with the area of large strain rate. As a conclusion, it could be stated that the our study represents the characteristics of crustal deformation in the southern part of peninsula, and contributes to the researches on earthquake disaster management.

Design-Based Properties of Least Square Estimators of Panel Regression Coefficients Based on Complex Panel Data (복합패널 데이터에 기초한 최소제곱 패널회귀추정량의 설계기반 성질)

  • Kim, Kyu-Seong
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.4
    • /
    • pp.515-525
    • /
    • 2010
  • We investigated design-based properties of the ordinary least square estimator(OLSE) and the weighted least square estimator(WLSE) in a panel regression model. Given a complex data we derive the magnitude of the design-based bias of two estimators and show that the bias of WLSE is smaller than that of OLSE. We also conducted a simulation study using Korean welfare panel data in order to compare design-based properties of two estimators numerically. In the study we found the followings. First, the relative bias of OLSE is nearly two times larger than that of WLSE and the bias ratio of OLSE is greater than that of WLSE. Also the relative bias of OLSE remains steady but that of WLSE becomes smaller as the sample size increases. Next, both the variance and mean square error(MSE) of two estimators decrease when the sample size increases. Also there is a tendency that the proportion of squared bias in MSE of OLSE increases as the sample size increase, but that of WLSE decreases. Finally, the variance of OLSE is smaller than that of WLSE in almost all cases and the MSE of OLSE is smaller in many cases. However, the number of cases of larger MSE of OLSE increases when the sample size increases.

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

Public Sentiment Analysis and Topic Modeling Regarding COVID-19's Three Waves of Total Lockdown: A Case Study on Movement Control Order in Malaysia

  • Alamoodi, A.H.;Baker, Mohammed Rashad;Albahri, O.S.;Zaidan, B.B.;Zaidan, A.A.;Wong, Wing-Kwong;Garfan, Salem;Albahri, A.S.;Alonso, Miguel A.;Jasim, Ali Najm;Baqer, M.J.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2169-2190
    • /
    • 2022
  • The COVID-19 pandemic has affected many aspects of human life. The pandemic not only caused millions of fatalities and problems but also changed public sentiment and behavior. Owing to the magnitude of this pandemic, governments worldwide adopted full lockdown measures that attracted much discussion on social media platforms. To investigate the effects of these lockdown measures, this study performed sentiment analysis and latent Dirichlet allocation topic modeling on textual data from Twitter published during the three lockdown waves in Malaysia between 2020 and 2021. Three lockdown measures were identified, the related data for the first two weeks of each lockdown were collected and analysed to understand the public sentiment. The changes between these lockdowns were identified, and the latent topics were highlighted. Most of the public sentiment focused on the first lockdown as reflected in the large number of latent topics generated during this period. The overall sentiment for each lockdown was mostly positive, followed by neutral and then negative. Topic modelling results identified staying at home, quarantine and lockdown as the main aspects of discussion for the first lockdown, whilst importance of health measures and government efforts were the main aspects for the second and third lockdowns. Governments may utilise these findings to understand public sentiment and to formulate precautionary measures that can assure the safety of their citizens and tend to their most pressing problems. These results also highlight the importance of positive messaging during difficult times, establishing digital interventions and formulating new policies to improve the reaction of the public to emergency situations.

ELECTRON MICROSCOPIC STUDY ON THE RESPONSES OF THE PERIODONTAL TISSUE ON THE TENSION SIDE FOLLOWING EXPERIMENTAL TOOTH MOVEMENT (실험적 치아 이동시 견인측 치주조직에 미치는 영향에 관한 전자현미경적 연구)

  • Chang, Ji Woo
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.65-81
    • /
    • 1984
  • In order to observe the responses of the periodontal tissue on the tension side following the experimental tooth movement, 35 Guinea pigs were divided into the control group (5 animals) and 6 experimental groups (3 movement groups and 3 retention groups) consisting of each 5 animals. The experimental tooth movement of Guinea pig's upper incisors installing open helical loop were carried out by rendering continuous force : 5g (1st groups) 35g (2nd groups), 100g (3rd groups), respectively for 7 days. 3 movement groups (15 animals) were sacrificed soon after the continuous force, and 3 retention groups (15 animals) were sacrificed after the retention period of another 7 days. The following results were obtained from the observation of the surrounding tissues of teeth on the tension side through light microscopy any transmission electron microscopy. 1. The vessel walls in the experimental groups were thinner than those of the control group, the number of blood vessel had the tendency to increase. The greater the strong force applied to each group, the more the destruction of cells and fibers was found and the more the number of the red blood cell of vessel outside appeared. 2. New collagen fibers were produced from fibroblasts in the 1st groups (light force), but were produced rather less in the 2nd groups (medium force) and the 3rd groups (heavy force). 3. In the forming patterns of the new alveolar bone of the 3rd groups (heavy force), the bone trabeculae were formed towards the direction of the force to be applied, but the new alveolar bone in the 1st groups (light force) was produced evenly throughout the all surfaces of the alveolar bone rather than the patterns of bone trabeculae ; therefore, the patterns of new alveolar bone were observed differently according to the magnitude of the force applied. 4. In the retention group, it was observed that the collagen fibers were produced from the osteoblasts in the marginal areas of the periodontal ligaments being widely opened and were deposited on the alveolar bone surface but the production of collagen fibers from the osteoblasts in the other area of the periodontal ligaments was almost ceased, and a rest line on the new alveolar bone surface was found.

  • PDF

Multiple Alternating Immunizations with DNA Vaccine and Replication-incompetent Adenovirus Expressing gB of Pseudorabies Virus Protect Animals Against Lethal Virus Challenge

  • Kim, Seon-Ju;Kim, Hye-Kyung;Han, Young-Woo;Aleyas, Abi G.;George, Junu A.;Yoon, Hyun-A;Yoo, Dong-Jin;Kim, Koan-Hoi;Eo, Seong-Kug
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.7
    • /
    • pp.1326-1334
    • /
    • 2008
  • The prime-boost vaccination with DNA vaccine and recombinant viral vector has emerged as an effective prophylactic strategy to control infectious diseases. Here, we compared the protective immunities induced by multiple alternating immunizations with DNA vaccine (pCIgB) and replication-incompetent adenovirus (Ad-gB) expressing glycoprotein gB of pseudorabies virus (PrV). The platform of pCIgB-prime and Ad-gB-boost induced the most effective immune responses and provided protection against virulent PrV infection. However, priming with pCIgB prior to vaccinating animals by the DNA vaccine-prime and Ad-boost protocol provided neither effective immune responses nor protection against PrV. Similarly, boosting with Ad-gB following immunization with DNA vaccine-prime and Ad-boost showed no significant responses. Moreover, whereas the administration of Ad-gB for primary immunization induced Th2-type-biased immunity, priming with pCIgB induced Th1-type-biased immunity, as judged by the production of PrV-specific IgG isotypes and cytokine IFN-$\gamma$. These results indicate that the order and injection frequency of vaccine vehicles used for heterologous prime-boost vaccination affect the magnitude and nature of the immunity. Therefore, our demonstration implies that the prime-boost protocol should be carefully considered and selected to induce the desired immune responses.

STRESS ANALYSIS OF SUPPORTING TISSUES AND IMPLANTS ACCORDING TO IMPLANT FIXTURE SHAPES AND IMPLANT-ABUTMENT CONNECTIONS (임플랜트 고정체의 형태와 연결방식에 따른 임플랜트 및 지지조직의 응력분포)

  • Han Sang-Un;Park Ha-Ok;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.226-237
    • /
    • 2004
  • Purpose: Four finite element models were constructed in the mandible having a single implant fixture connected to the first premolar-shaped superstructure, in order to evaluate how the shape of the fixture and the implant-abutment connection would influence the stress level of the supporting tissues fixtures, and prosthethic components. Material and methods : The superstructures were constructed using UCLA type abutment, ADA type III gold alloy was used to fabricate a crown and then connected to the fixture with an abutment screw. The models BRA, END , FRI, ITI were constructed from the mandible implanted with Branemark, Endopore, Frialit-2, I.T.I. systems respectively. In each model, 150 N of vertical load was placed on the central pit of an occlusal plane and 150 N of $40^{\circ}$ oblique load was placed on the buccal cusp. The displacement and stress distribution in the supporting tissues and the other components were analysed using a 2-dimensional finite element analysis . The maximum stress in each reference area was compared. Results : 1. Under $40^{\circ}$ oblique loading, the maximum stress was larger in the implant, superstructure and supporting tissue, compared to the stress pattern under vertical loading. 2. In the implant, prosthesis and supporting tissue, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 3. In the superstructure and implant/abutment interface, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 4. In the implant fixture, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 5 The stress was more evenly distributed in the bone/implant interface through the FRI of trapezoidal step design. Especially Under $40^{\circ}$ oblique loading, The maximum stress was smallest in the bone/implant interface. 6. In the implant and superstructure and supporting tissue, the maximum stress occured at the crown loading point through the ITI. Conclusion: The stress distribution of the supporting tissue was affected by shape of a fixture and implant-abutment connection. The magnitude of maximum stress was reduced with the internal connection type (FRI) and the morse taper type (ITI) in the implant, prosthesis and supporting tissue. Trapezoidal step design of FRI showed evenly distributed the stress at the bone/implant interface.

A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM (수종 임플랜트 시스템에서의 회전력에 관한 연구)

  • Moon, Ick-Hun;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

A Study on the Sounds and Vibrations of the Temporomandibular Joint using Electrovibratography (전자 진동술을 이용한 악관절의 잡음과 진동에 관한 연구)

  • Seok-Man Kang;Kyung-Soo Han;Min Shin
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.141-158
    • /
    • 1995
  • This study was performed to invetigate the relationship between clinical manifestations related to temporomandibular joint sounds and temporomandibular joint vibrations that occurred synchronously with sounds. There have been reported in many articles that joint sounds indicate internal joint pathology. Therefore, it is necessary to evaluate type and patterns of joint sounds, and radiographic changes of temporomandibular joint(TMJ) in order to diagnose and deal with the Temporomandibular Disorders(TMD). For this study 142 patients with TMDs were collected and they were examined by routine diagnostic procedure for TMDs. The author classified TMJ sounds clinically into 3 types : click, popping, and crepitus. Transcranial and panoramic radiographs were taken for observein bony changes of TMJ, and for observing vibrations of TMJ Sonopak of Biopak system was used. The obtained results were as follows : 1. Female subjects with crepitus were older than those with click or popping and their mean ages were about 45 years old. But in male subjects, there was no age difference. 2. For all subjects, mean value of maximal mouth opening were above 40mm, which are lower limit of normal vertical opening. But in subjects with L-type opening deviation, mouth opening capacity were about 36mm of range. 3. Symptom duration stated when patient presented first were slightly longer in subjects with crepitus but there were no statistical differences. And there were also no radiographic differences among 3 types of joint sounds in regard to symptom duration. 4. In subjects wih click, it might have been interpreted that 12% had closed lock, 12% had degenerative joint disease, and about 17% of he subjects had normal joints by Sonopak. 5. There were no significant relationships between subjective loudness of joint sounds and magnitude of joint vibrations. 6. The highest value of Integral and peak amplitude were observed in popping sounds and though it was not significant, value of peak frequency was highest in crepitus. 7. Amount of mandibular positional change were differed between click and crepitus on frontal plane, between click, crepitus and popping on horizontal plane in rotational movement, respectively. However, there no difference among them in translational movements.

  • PDF

An Analysis of Determinants of Medical Cost Inflation using both Deterministic and Stochastic Models (의료비 상승 요인 분석)

  • Kim, Han-Joong;Chun, Ki-Hong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.542-554
    • /
    • 1989
  • The skyrocketing inflation of medical costs has become a major health problem among most developed countries. Korea, which recently covered the entire population with National Health Insurance, is facing the same problem. The proportion of health expenditure to GNP has increased from 3% to 4.8% during the last decade. This was remarkable, if we consider the rapid economic growth during that time. A few policy analysts began to raise cost containment as an agenda, after recognizing the importance of medical cost inflation. In order to Prepare an appropriate alternative for the agenda, it is necessary to find out reasons for the cost inflation. Then, we should focus on the reasons which are controllable, and those whose control are socially desirable. This study is designed to articulate the theory of medical cost inflation through literature reviews, to find out reasons for cost inflation, by analyzing aggregated data with a deterministic model. Finally to identify determinants of changes in both medical demand and service intensity which are major reasons for cost inflation. The reasons for cost inflation are classified into cost push inflation and demand pull inflation, The former consists of increases in price and intensity of services, while the latter is made of consumer derived demand and supplier induced demand. We used a time series (1983-1987), and cross sectional (over regions) data of health insurance. The deterministic model reveals, that an increase in service intensity is a major cause of inflation in the case of inpatient care, while, more utilization, is a primary attribute in the case of physician visits. Multiple regression analysis shows that an increase in hospital beds is a leading explanatory variable for the increase in hospital care. It also reveals, that an introduction of a deductible clause, an increase in hospital beds and degree of urbanization, are statistically significant variables explaining physician visits. The results are consistent with the existing theory, The magnitude of service intensity is influenced by the level of co-payment, the proportion of old age and an increase in co-payment. In short, an increase in co-payment reduced the utilization, but it induced more intensities or services. We can conclude that the strict fee regulation or increase in the level of co-payment can not be an effective measure for cost containment under the fee for service system. Because the provider can react against the regulation by inducing more services.

  • PDF