• 제목/요약/키워드: Orbital wall fracture

검색결과 81건 처리시간 0.023초

안와벽 파열골절에 대한 임상적 고찰 (Survey and Review of Blowout Fractures)

  • 은석찬;허찬영;백롱민;민경원;정철훈;오석준
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.599-604
    • /
    • 2007
  • Purpose: Blowout fractures of the orbit are common sequelae to blunt facial trauma and now increasing in number due to automobile accidents, violence and industrial disasters. There are some reports of diagnosis and treatment of this fracture, but detailed data provided in overall aspects are very few. We analysed extensive data to provide guide line of blowout fracture patients care. Methods: We retrospectively studied 387 orbital blowout fracture patients who had been followed up at least 3-6 months. Their hospital records were reviewed according to causes, fracture site, operation methods, and follow up results, etc. Results: The ratio of males to females was 7 : 3 and fractures were most often seen in the 20-29 age group. 180(47%) patients had medial orbital wall fractures, 155(40%) patients had floor fractures and 52(13%) patients had a combination of orbital floor and medial wall fractures. The highest associated bone fracture was the nasal bone(37%). The open reduction was done in the 324 patients(83.7%) and insertion materials were used in the 249 patients(77%). Total 45 patients(14%) complained of residual diplopia and 26 patients(8%) kept mild enophthalmos. 24 patients(7%) showed some restriction of extraocular muscle movements. Conclusion: We broadly surveyed the information of blow out fracture patients and believe that this study provides important prognostic information that can be of benefit to both patient and surgeon during preoperative counseling and postoperative analysis of orbital blowout fractures.

Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

  • Cha, Jong Hyun;Lee, Yong Hae;Ruy, Wan Chul;Roe, Young;Moon, Myung Ho;Jung, Sung Gyun
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.146-153
    • /
    • 2016
  • Background: Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods: This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results: All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from $1.0952{\pm}0.0662$ (ranging from 0.9917 to 1.2509) preoperatively to $0.9942{\pm}0.0427$ (ranging from 0.9394 to 1.0680) postoperatively. Conclusion: The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system.

Considerations for the Management of Medial Orbital Wall Blowout Fracture

  • Kim, Yong-Ha;Park, Youngsoo;Chung, Kyu Jin
    • Archives of Plastic Surgery
    • /
    • 제43권3호
    • /
    • pp.229-236
    • /
    • 2016
  • Recently, diagnoses of and operations for medial orbital blowout fracture have increased because of the development of imaging technology. In this article, the authors review the literature, and overview the accumulated knowledge about the orbital anatomy, fracture mechanisms, surgical approaches, reconstruction materials, and surgical methods. In terms of surgical approaches, transcaruncular, transcutaneous, and transnasal endoscopic approaches are discussed. Reconstruction methods including onlay covering, inlay implantation, and repositioning methods are also discussed. Consideration and understanding of these should lead to more optimal outcomes.

경중도 안와 내벽 골절의 수술 시 흉터 최소화를 위한 변형된 직접 W-절개법과 실리콘판을 이용한 재건 (Modified Direct W-incision with Silicone Sheet to Minimize Operation Scar in Reconstruction of Mild to Moderate Symptomatic Medial Orbital Wall Fracture)

  • 정재아;공정식;김양우;강소라
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.30-35
    • /
    • 2013
  • Background: For reconstruction of the mild to moderate medial orbital wall fractures, various surgical approaches have been used. Prior existing W-shaped incision was a direct local approach through a 3 cm incision on the superior medial orbital area with a titanium mesh implant. In this study, the authors modified W-shaped incision and reconstructed the defect with silastic sheet to improve the result and the postoperative scar. Methods: This study included 20 patients who had mild to moderate size of medial wall defect and therefore relatively suitable for reconstruction with silastic sheets from July, 2009 to December, 2011. A modified W-shaped skin incision approximately 1.2 to 1.5 cm in length was made along the superior medial orbital rim from approximately 1 cm medial to the medial canthus to the lower border of the medial eyebrow. The angles of the limbs of the W ranged from 150 to 160 degrees. Results: By using soft flexible silastic sheet, the authors reduced the incision from 3 to 1.5 cm, and by widening the angle of the W limbs, scars were more effectively hided in the relaxed skin tension line. Scar assessment was done with modified patient and observer scar assessment scale and mean score from patients was 2.08 and mean score from observers was 2.12. Conclusion: Although this method will not be suitable for every case, it can be a consistent method to obtain the surgical goal in treatment of mild to moderate blowout fractures of the medial orbital wall.

안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰 (CT Observation of Alloplastic Materials Used in Blow Out Fracture)

  • 이원;강동희
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Prevalence of Diplopia and Extraocular Movement Limitation according to the Location of Isolated Pure Blowout Fractures

  • Park, Min-Seok;Kim, Young-Joon;Kim, Hoon;Nam, Sang-Hyun;Choi, Young-Woong
    • Archives of Plastic Surgery
    • /
    • 제39권3호
    • /
    • pp.204-208
    • /
    • 2012
  • Background : Isolated pure blowout fractures are clinically important because they are the main cause of serious complications such as diplopia and limitation of extraocular movement. Many reports have described the incidence of blowout fractures associated with diplopia and limitation of extraocular movement; however, no studies have statistically analyzed this relationship. The purpose of this study was to demonstrate the correlation between the location of isolated pure blowout fractures and orbital symptoms such as diplopia and limitation of extraocular movement. Methods : We enrolled a total of 354 patients who had been diagnosed with isolated pure blowout fractures, based on computed tomography, from June 2008 to November 2011. Medical records were reviewed, and the prevalence of extraocular movement limitations and diplopia were determined. Results : There were 14 patients with extraocular movement limitation and 58 patients complained of diplopia. Extraocular movement limitation was associated with the following findings, in decreasing order of frequency: floor fracture (7.1%), extended fracture (3.6%), and medial wall (1.7%). However, there was no significant difference among the types of fractures (P=0.60). Diplopia was more commonly associated with floor fractures (21.4%) and extended type fractures (23.6%) than medial wall fractures (10.4%). The difference was statistically significant (Bonferroni-corrected chi-squared test P<0.016). Conclusions : Data indicate that extended type fractures and orbital floor fractures tend to cause diplopia more commonly than medial wall fractures. However, extraocular movement limitation was not found to be dependent on the location of the orbital wall fracture.

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

  • Choi, Tae Joon;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • 제43권1호
    • /
    • pp.84-87
    • /
    • 2016
  • Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

Eyeball deviation by orbital mucocele after midface sinus injury

  • Oh, Se Young;Choi, Ji Seon;Lim, Jin Soo;Kim, Min Cheol
    • 대한두개안면성형외과학회지
    • /
    • 제21권1호
    • /
    • pp.53-57
    • /
    • 2020
  • A mucocele is an epithelium-lined, mucus-filled cavity in the paranasal sinuses. Mucocele may develop due to scarring and obstruction of the sinus ostium caused by midface sinus trauma, such as orbital bone fracture or endoscopic sinus surgery. The authors report two cases of orbital mucocele as complications following midface sinus injury (endoscopic sinus surgery in one case, and orbital fracture repair in the other). In both cases, imaging studies showed a large orbital mucocele accompanied by bony erosion and orbital wall remodeling, compressing the ocular muscle. Using an open approach, the lesion was excised and marsupialized. The symptoms resolved, and the postoperative eyeball position was normal. Orbital mucocele may cause serious complications such as ocular symptoms, orbital cellulitis, osteomyelitis, and the formation of an abscess with the potential to invade the brain. Therefore, surgeons should consider the possibility of mucocele as a late complication of surgery and initiate an immediate work-up and surgical treatment if needed.

Late reconstruction of extensive orbital floor fracture with a patient-specific implant in a bombing victim

  • Smeets, Maximiliaan;Snel, Robin;Sun, Yi;Dormaar, Titiaan;Politis, Constantinus
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권5호
    • /
    • pp.353-357
    • /
    • 2020
  • Fractures of the orbital floor and walls are among the most frequent maxillofacial fractures. Virtual three-dimensional (3D) planning and use of patient-specific implants (PSIs) could improve anatomic and functional outcomes in orbital reconstruction surgery. The presented case was a victim of a terrorist attack involving improvised explosive devices. This 58-year-old female suffered severe wounds caused by a single piece of metal from a bomb, shattering the left orbital floor and lateral orbital wall. Due to remaining hypotropia of the left eye compared to the right eye, late orbital floor reconstruction was carried out with a personalised 3D printed titanium implant. We concluded that this technique with PSI appears to be a viable method to correct complex orbital floor defects. Our research group noted good aesthetic and functional results one year after surgery. Due to the complexity of the surgery for a major bony defect of the orbital floor, it is important that the surgery be executed by experienced surgeons in the field of maxillofacial traumatology.

안와 파열 골절의 분류 (Classification of Blowout Fracture)

  • 이준호;류민희;김용하
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.719-723
    • /
    • 2007
  • Purpose: Blowout fracture can lead to functional impairments and esthetic deformities such as impairment of ocular movement, diplopia, visual loss and enophthalmos. The object of this study is to present a classification and its analysis according to the computed tomographic scan in blowout fractures. We classified blow out fractures into three types according to the anatomical location of fracture, the size of the bone defect and the degree of periosteal injury by using the computed tomography scan. Each progress and complications were analyzed more than mean 1 year. Methods: Among the 155 cases during 4 years, there were 11 cases of medial orbital wall fracture, 97 cases of inferior orbital wall fracture, 47 cases of combined type. The mean age of patients was 31.2 years, ranged from 8 to 84 years. Results: According to our classification, surgical treatments through the nasoendoscopic approach, the subciliary approach, the transconjunctival approach or their combinations were performed in 116 patients, and conservative treatments were done in 46 patients. Presurgical clinical findings of diplopia, impairment of ocular movement, enophthalmos of more than 2 mm were present in 62 patients. After surgical treatment, clinical findings were remained in 7 patients. Conclusion: We think that our classification according to computed tomographic scan is helpful for the indication and it may decrease the complications such as impairment of ocular movement, diplopia, visual loss and enophthalmos.