• Title/Summary/Keyword: Optimum Position

Search Result 540, Processing Time 0.028 seconds

Electrochemical Template Synthesis of Conducting Polymer Microstructures at Addressed Positions (템플레이트의 국소 위치에 형성된 전도성 고분자 미세구조물의 전기화학 합성)

  • Lee Seung Hyoun;Suh Su-Jeong;Yun Geum-Hee;Son Yongkeun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2004
  • The nano or micro sized structures of conducting polymer had been prepared by synthesizing the desired polymer within the pores of template of nano or micro porous membrane filter. In this study, we had tried to fabricate conducting polymer microstructures on an electrode by using electrochemical deposition adopting template synthesis. Our attention was focused on two different things, attaching template on the electrode and fabricating microstructures only at limited areas of the electrode. A conducting polymer, PEDiTT (poly 3,4-ethylenedithi-athiophene) solution was blended with PVA(polyvinyl alcohol) solution and used as an conducting adhesive. After attaching template membrane, the electrode were immersed in 0.5M pyrrole in 0.1M KCI solution, and electrochemical polymerization was performed. The growth process of the microstructures studied by SEM. The electrochemical fabrication of conducting polymer was performed by using two-electrode system. A large working electrode and a micro scale disc electrode were used for the confined area synthesis. Polymerization potential was 4V in an electrolytic solution made of KCI in deionized water. The optimum polymerization conditions were, i.e. (4V/100sec) for $250{\mu}m$ electrode and (6V/30 sec) for $10{\mu}m$ electrode.

A Study on Friction Welding of SM45C to SCM4 Steel Bars and the Fatigue Properties (SM45C와 SCM4의 마찰용접 및 피로특성에 관한 연구)

  • O, Se-Gyu;Kim, Bu-An;Kim, Seon-Jin;Nam, Sang-Hun
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.112-121
    • /
    • 1988
  • A study on friction welding of carbon steel bar (SM45C) to chrome molybedenum steel bar(SCM4) is examined experimentally through tensile test, hardness test, microstructure test and fatigue test. so, this paper deals with optimizing the welding concitions and analyzing various mechanical properties about friction welds of SM45C to SCM4 steel bars. The results obtained are summarized as follows; 1) For friction welded joints of SM45C to SCM4 steel bars, the total upset(U)increases linearly with an increase of heating time ($t_{1}$) till 6s. 2) The determined optimum welding conditions are heating time ($t_{1}$)2s, upsetting time($t_{2}$), 3s, heating pressure($p_{1}$), 4kgf/$mm^{2}$(39.2MPa), upsetting pressure($p_{2}$, 8kgf/mm$^{2}$(78.4MPa) and rotating speed(N), 2, 000rpm when the total upset(U) is 3.4mm, resulting in a computed relationship between the joint tensile strength .sigma.$_{t}$ (kgf/mm$^{2}$and the total upset U(mm); .sigma.$_{t}$ =$0.21U^{3}$ - $3.38U^{2}$ +17.03U + 66.00 3) As the elongation is increased more and more, the fracture position becomes away from weld interface and the fractures are similar to those of SM45C. Fracture is taken place on SM45C side. 4) The weld interface of two dissimilar materials is mixed strongly, and the heat affected zone is about 2.0mm at SM45C while about 2.7 mm at SCM4 side. Therefore, the welded zone and heat affected zone are very narrow, comparing with those of the joints welded by the other welding methods. 5) The fatigue strengths at N=10$^{6}$ cycles of SM45C, SCM4 and friction welded joints are 23kgf/$mm^{2}$, 33kgf/$mm^{2}$(220.5 MPa), and 22.5kgf/$mm^{2}$(220.5MPa) respectively, and fracture at friction welded joint takes place at the side of SM45C. 6) The hardness of the friction weld interface is 3 times higher than that of base metal. 7) Fatigue strength of friction welded joint is higher than that of base metal. 8) Notch sensitivity factor of friction welded joint is lower than that of base metal.

  • PDF

Formation of Anatawe type TiO2 from Titanic acid (Titanic acid로부터 Anatase형 $TiO_2$의 형성에 관한 연구)

  • Kim, Hern;Kim, Dae-Woong;Lee, Kyung-Hee;Baik, Woon-Phil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.5
    • /
    • pp.510-515
    • /
    • 1999
  • Synthesize of anatase type $TiO_2$ from $TiCl_4$ solution was studied. KOH was used on dehydration reaction of $TiCl_4$ solution. Products of dehydration reaction was calcined at 300, 500, 700, 900, $1000^{\circ}C$ during 1hour. Calcined products was studied by XRD, DTA, and FT-IR for effect of calcined temperature. The results are as follow. \circled1 Product pf dehydration reaction at$ 90^{\circ}C$ was semicrystalline anatase type $TiO_2$ because it has a peak vary broad and low at the position of anatase crysral XRD pattern. \circled2 Pure titanium oxide semi-crystalline products were produced at acid pH condition which convert to anatase crystal at $300^{\circ}C$ and to rutile crystal at $700^{\circ}C$. \circled3 The chemical composition of semicrystalline products which was produce at alkali pH conditions, were potasium titante. Potasium-titanate semi-crystalline products crystallized at 630~$640^{\circ}C$ \circled4 The transition temperature of potassium dopped titanium oxide semi-crystalline products was increased with the contents of potasium. \circled5 The optimum synthesise condition of anatase $TiO_2$ products from $TiCl_4$ and KOH are pH 3~5 and $300^{\circ}C$ calcination.

  • PDF

Effects of Silicone Polymer Blends on Physical Properties of Dental Polyvinylsiloxane Impression Materials (실리콘폴리머의 혼합사용이 폴리비닐실록산 치과용 인상재의 물성에 미치는 영향)

  • Lim, Chang-Ha;Kim, Min-Kang;Kim, Young-Chul;Park, Nam-Cook;Song, Ho-Jun;Park, Yeong-Joon
    • Elastomers and Composites
    • /
    • v.44 no.1
    • /
    • pp.76-83
    • /
    • 2009
  • The purpose of this study was to investigate the effects of combined use of several types of silicone polymers on the physical properties of the dental polyvinylsiloxane impression materials (PVS). Four types of silicone prepolymers having different molecular weight and vinyl group position, and two types of cross-linkers having differently located silyl hydride functional groups were used in various combinations for the formulation. The samples containing bimodal or trimodal prepolymers showed higher tensile strength, elongation at break, and elastic deformation than those containing only one type of prepolymer. The samples using CR210 cross-linker which has side- and terminal-silyl hydride groups showed higher elastic deformation and elongation at break than those using CR101 cross-liker which has side-only silyl hydride group. High vinyl content prepolymer having side vinyl group delayed setting even though it enhanced tensile strength. Further studies are needed to clarify the specific role of this component on setting time and to find appropriate controlling methods for making improved PVS with optimum workability.

A Study on the Design of Wideband Microstrip Cross Slot Array Antennas with Circular Polarization (원편파용 광대역 마이크로스트립 크로스 슬롯 어레이 안테나의 설계에 관한 연구)

  • Min, Kyeoung-sik;Ko, Jee-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.894-900
    • /
    • 2004
  • There are many types of circularly polarized(CP) microstrip antenna elements, which are used as a good unit radiator. Since an advantage of CP antenna is no strict alignment requirements between Rx and Tx system, the printed antennas with circular polarization are very often used in numerous satellite and mobile radio systems. In order to realize the broad bandwidth of 3 dB axial ratio and impedance of CP microstrip antenna, complex feed structure and tri-plate patch element have been researched. This paper describes a design of wideband microstrip cross slot array antennas with circular polarization. The proposed antenna is composed of an open-ended microstrip feed line as a feeder and a cross slot as a radiator for circular polarization. To realize the wide bandwidth, tri-plate structure are considered and cross slot is electromagnetically coupled with feed line. Optimum parameters of 1-element cross slot antenna are analyzed and designed by method of moments. These parameters are also applied to may antennas design considered the mutual coupling between radiating elements. Right hand circular polarization(RHCP) and left hand circular polarization(LHCP) of the proposed antenna are easily controlled by asymmetrical cross slot structure and slot position. In 1-element and 15-element cross slot array antenna, the good axial ratio of 1 dB below and the broad bandwidth characteristics of antenna are obtained.

Characteristics of Wave Response in a 'Y' Shape Water Channel Resonator Using Resonance of Internal Fluid (내부유체 공진을 이용한 'Y'자 수로형 공명구조물내 파도응답 특성)

  • Kim, Jeongrok;Cho, Il Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.3
    • /
    • pp.170-179
    • /
    • 2019
  • In this study, the wave responses in a 'Y'shape water channel resonator for amplifying wave energy of a low density has been investigated. A water channel resonator is composed of the long channel and wave guider installed at the entrance. If the period of the incident waves coincides with the natural period of the fluid in a water channel resonator, resonance occurs and the internal fluid amplifies highly to a standing wave form. In order to analyze the wave response in a water channel resonator, we used the matched asymptotic expansion method and boundary element method. The both results were in good agreement with the results of the model test carried out in the two-dimensional wave tank of Jeju National University. Wave guider has an optimum length and installation angle according to the period of the incident wave, and especially effective in enhancing the amplification factor in a period range deviated from the resonance period. It is expected that the wave energy can be effectively extracted by placing the point absorber wave energy converter at the position of anti-node where the maximum wave height is formed by the internal fluid resonance.

A Deep-Learning Based Automatic Detection of Craters on Lunar Surface for Lunar Construction (달기지 건설을 위한 딥러닝 기반 달표면 크레이터 자동 탐지)

  • Shin, Hyu Soung;Hong, Sung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.859-865
    • /
    • 2018
  • A construction of infrastructures and base station on the moon could be undertaken by linking with the regions where construction materials and energy could be supplied on site. It is necessary to detect craters on the lunar surface and gather their topological information in advance, which forms permanent shaded regions (PSR) in which rich ice deposits might be available. In this study, an effective method for automatic detection of lunar craters on the moon surface is taken into consideration by employing a latest version of deep-learning algorithm. A training of a deep-learning algorithm is performed by involving the still images of 90000 taken from the LRO orbiter on operation by NASA and the label data involving position and size of partly craters shown in each image. the Faster RCNN algorithm, which is a latest version of deep-learning algorithms, is applied for a deep-learning training. The trained deep-learning code was used for automatic detection of craters which had not been trained. As results, it is shown that a lot of erroneous information for crater's positions and sizes labelled by NASA has been automatically revised and many other craters not labelled has been detected. Therefore, it could be possible to automatically produce regional maps of crater density and topological information on the moon which could be changed through time and should be highly valuable in engineering consideration for lunar construction.

Evaluation of Effective Sensing Distance and Measurement Efficiency for Ground-Based Remote Sensors with Different Leaf Distribution in Tobacco Plant (연초의 엽위 분포형태에 따른 지상 원격센서의 유효 탐사거리와 측정 효율성 평가)

  • Jeong, Hyun-Cheol;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.2
    • /
    • pp.126-136
    • /
    • 2008
  • Tobacco plants grown in pots by sand culture for 70 days after transplanting were used to evaluate the sensing distance and measurement efficiency of ground-based remote sensors. The leaf distribution of tobacco plant and sensing distance from the sensors to the target leaves were controlled by two removal methods of leaves, top-down and bottom-up removal. In the case of top-down removal, the canopy reflectance was measured by the sensor located at a fixed position having an optimum distance from the detector to the uppermost leaf of tobacco every time that the higher leaves were one at a time. The measurement of bottom-up removal, a the other hand, was conducted in the same manner as that of the top-down removal except that the lower leaves were removed one by one. Canopy reflectance measurements were made with hand held spectral sensors including the active sensors such as $GreenSeeker^{TM}$ red and green, $Crop\;Circle\;ACS-210^{TM}$ red and amber, the passive sensors of $Crop\:Circle^{TM}$, and spectroradiometer $SD2000^{TM}$. The reflectance indices by all sensors were generally affected by the upper canopy condition rather than lower canopy condition of tobacco regardless of sensor type, passive or active. The reflectance measurement by $GreenSeeker^{TM}$ was affected sensitively at measurement distance longer than 120 cm, the upper limit of effective sensing distance, beyond which measurement errors are appreciable. In case of the passive sensors that has no upper limit of effective distance and $Crop\;Circle^{TM}(ACS210)$ that has the upper limit of effective sensing distance specified with 213 cm, longer than that of estimated distance, the measurement efficiency affected by the sensing distance showed no difference. This result suggests that it is necessary to use the sensor specified optimum distance. The result revealed that active sensors are more superior than their passive counterparts in establishing between the relative ratio of reflectance index and the dry weight of tobacco treated by top-down removal, and in the evaluation of biomass. $The\;Crop\;Circle\;ACS-210^{TM}$ red was proved to have the highest efficiency of measurement, followed by $Crop\;Circle^{TM}(ACS210)$ amber and $GreenSeeker^{TM}$ red, $Crop\;Circle^{TM}$ passive, $GreenSeeker^{TM}$ green, and spectroradiometer, in descending order.

Pharmacological Comparison of Timosaponin A III on the 5-beta Reductase and Androgen Receptor via In Silico Molecular Docking Approach (In silico 약리학적 분석을 통한 티모사포닌 A III의 5-베타 리덕타아제 단백질 및 안드로겐 수용체 단백질 활성 부위에 대한 결합 친화도 비교 연구)

  • Kim, Dong-Chan
    • Journal of Life Science
    • /
    • v.28 no.3
    • /
    • pp.307-313
    • /
    • 2018
  • Alopecia cause psychological stress due to their effect on appearance. Thus, the global market size of the alopecia treatment products are growing quickly. Timosaponin A III is the well known active ingredient of Anemarrhenae Rhizoma. In this study, we investigated and compared the binding affinity of timosaponin A III with finasteride (5-beta reductase antagonist) and minoxidil (androgen receptor antagonist) on the target protein active site by in silico computational docking studies. The three dimensional crystallographic structure of 5-beta reductase (PDB ID : 3G1R) and androgen receptor (PDB ID: 4K7A) was obtained from PDB database. In silico computational autodocking analysis was performed using PyRx, Autodock Vina, Discovery Studio Version 4.5, and NX-QuickPharm option based on scoring functions. The timosaponin A III showed optimum binding affinity (docking energy) with 5-beta reductase as -12.20 kcal/mol as compared to the finasteride (-11.70 kcal/mol) and with androgen receptor as -9.00 kcal/mol as compared to the minoxidil (-7.40 kcal/mol). The centroid X, Y, Z grid position of the timosaponin A III on the 5-beta reductase was similar (overlap) to the finasteride, but the X, Y, Z centroid grid of the timosaponin A III on the androgen receptor was significantly far from the minoxidil centroid position. These results significantly indicated that timosaponin A III could be more potent antagonist to the 5-beta reductase and androgen receptor. Therefore, the extract of Anemarrhenae Rhizoma or timosaponin A III containing biomaterials can substitute the finasteride and minoxidil and can be applied to the alopecia protecting product and related industrial fields.

The propriety of Spatial Arrangement Condition of 119 Emergency Medical Service - Mainly Around H Town Area, Countrysid of Y city - (119지역대의 공간적 배치 현황의 적절성 -Y시 H면 지역을 중심으로-)

  • Yun, Jong-Geun;Choi, Kyu-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.374-380
    • /
    • 2017
  • In this study, we analyzed the situation of the 119 emergency medical service zone of H town, countryside of Y city from January 1st, 2015 to December 31st, 2016 and then, on the basis of this analysis, we investigated the present condition of the patient-transportation service of the 119 emergency medical service to provide the basic data in order for patients to use the emergency medical service more efficiently. We analyzed the data with SPSS 21.0 using frequency analysis and, after positioning the virtual 119 emergency medical service, we analyzed the data of the transportation time and transportation distance by using GIS. The results of this study show that the use of the 119 emergency medical service for people over 65 years old represents approximately 57% of the total number of patients transported, The average distance and time of the real moving reaction are 6.41 km and 11.86 min, respectively. The distance and time from the pick-up location to the hospital are 18.24 km and 21.52 min, respectively. Given the present position of the 119 emergency medical service, the results of this analysis using GPS show that the (average) distance and time from the 119 emergency medical service to Jang * Ri town are 9.12 km and 12 min, and the (average) total distance and time to arrive at the hospital after the emergency medical service picks up the patient are 36.83 km and 62 min, respectively. In the case of the virtual emergency medical service, the total distance and time required to arrive at the hospital after the emergency medical service picks up the patient are 27.71km and 50min, respectively. The results of this study showed that the present position of the 119 emergency service does not provide the optimum distance and time from the patient's location to the hospital. Therefore, we consider that the repositioning of the 119 emergency medical center is necessary, in order to reduce the time required for the emergency medical service to move to the patient's location and then bring the patient to the hospital.