• 제목/요약/키워드: Optimum Coagulation pH

검색결과 78건 처리시간 0.032초

상수처리시스템 응집제 주입공정 퍼지 모델링과 제어 (Fuzzy modeling and control for coagulant dosing process in water purification system)

  • 이수범;남의석;이봉국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.282-285
    • /
    • 1996
  • In the water purification plant, the raw water is promptly purified by injecting chemicals. The amount of chemicals is directly related to water quality such as turbidity, temperature, pH and alkalinity. At present, however, the process of chemical reaction to the turbidity has not been clarified as yet. Since the process of coagulant dosage has no feedback signal, the amount of chemical can not be calculated from water quality data which were sensed from the plant. Accordingly, it has to be judged and determined by Jar-Test data which were made by skilled operators. In this paper, it is concerned to model and control the coagulant dosing process using jar-test results in order to predict optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride). The considering relations to the reaction of coagulation and flocculation, the five independent variables(turbidity, temperature, pH, Alkalinity of the raw water, PAC feed rate) are selected out and they are put into calculation to develope a neural network model and a fuzzy model for coagulant dosing process in water purification system. These model are utilized to predict optimum coagulant dosage which can minimize the water turbidity in flocculator. The efficacy of the proposed control schemes was examined by the field test.

  • PDF

차아염소산과 철염을 이용한 하수슬러지의 탈수효과 (The Effect of the Use of Sodium Hypochlorite and Iron Salts on Sewage Sludge Dewaterability)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제35권1호
    • /
    • pp.58-63
    • /
    • 2009
  • This study investigated improvement to sludge dewaterability and coagulation for sewage treatment plant sludge by using sodium hypochlorite solution (NaOCl), ferric sulfate [$Fe_2(SO_4)_3$] and zeolite. The specific resistance to filtration(SRF), chloride, pH and turbidity were used to evaluate the sludge dewatering behaviors. The results of study were as follows: By varying the amount of NaOCl added the optimum result in terms of enhancement for pretreatment occurred when 34 mg/l of NaOCl was injected. When the total solids concentration of the sludge was 10,000 mg/l, the optimum ferric sulfate dosage for the sludge dewaterability was 150 mg/l and the corresponding SRF was $1.7{\times}10^7sec^2/g$. It was observed that injecting zeolite into sludge was effective in improving the dewaterability of sludge.

낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거 특성 (Characteristics of DOC Removal by Coagulation Process in the Water Treatment of Nakdong River)

  • 황덕흥;김동윤
    • 상하수도학회지
    • /
    • 제13권2호
    • /
    • pp.66-73
    • /
    • 1999
  • This study was carried out to derive the removal characteristics of target materials(DOC and turbidity) during the coagulation process after the injection of coagulants(PACl and FeCl3). Used apparatus were a jar test and a pilot plant. A great portion of DOC among the total removed DOC was achieved at the slow mixing process among the coagulation process. The ranges of removed DOC and optimum pH for each coagulant were 0.45~1.47mg/l and 6.0~6.5 by PACl, and 0.97~2.61mg/l. and 5.0~5.5 by FeCl3, respectively. Both of coagulants showed little increase of DOC removal above coagulant dosage 20mg/l Molecular weight distribution(MWD) of removed DOC was measured by get filtration(GF) technique. The MWD variation by gel filtrationin(GF) for removed DOC in the coagulation process were as follows; for raw water, the percentages of each MWD for total area were < MW 6,500 25.5%, MW 6,500~66,000 67.1%, and > MW 66,000 7.4%. For the same coagulant dosage(12mg/l), the percentages of each MWD for total area by PACl were < MW 6,500 20.5%, MW 6,500~66,000 48.7%, and > MW 66,000 9.1%, and those of FeCl3 were MW 66,000 18.2%. For each coagulant, the removal percentage of MW 6,500~66,000 occurred a little, but at a part of

  • PDF

수도관 내부부식방지를 위한 CCPP 조절시 정수공정내에서의 수질변화 (Water Quality Variation on the Unit Operation of Water Treatment Process When CCPP Index was Controlled for Internal Corrosion of Water Pipes)

  • 이재인;김도환;이지형;김동윤;홍순헌;신판세
    • 대한환경공학회지
    • /
    • 제27권4호
    • /
    • pp.362-368
    • /
    • 2005
  • 본 연구에서는 수도관부식방지를 위해 정수공정에 탄산가스와 소석회, 소다회를 주입함으로 pH, 알칼리도, 칼슘경도와 같이 부식에 영향을 미치는 수질을 조절하여 운전하였다. 탄산가스와 소석회는 정수공정 중 응집제주입 이전에, 소다회는 정수공정의 마지막 단계인 BAC 처리 후에 주입하여 정수공정 내의 수질변화에 미치는 영향을 고찰하였다. pH와 알칼리도는 응집조에서 감소한 후 침전이후 BAC 공정까지 일정하게 되었으며, 칼슘경도는 응집조에서 증가한 후 BAC 공정까지 큰 변화 없이 일정하였다. 연구기간동안 탄산가스와 소석회주입으로 탁도 발생과 DOC 제거율에 미치는 영향은 거의 없었다. 최종처리수의 평균수질은 pH 8.39, 알칼리도 $61.4\;mg/L$ as $CaCO_3$, 칼슘경도 59.4 mg/L as $CaCO_3$였고, CCPP 지수는 BAC 처리수보다 평균 29.5 mg/L 상승시켜 CCPP $\geq$ 0으로 조절하여 수도관내 부식방지효과를 기대할 수 있었다.

pH와 완속교반 조건에 따른 중금속 수산화물 화학침전 특성 (Effects of pH and slow mixing conditions on heavy metal hydroxide precipitation)

  • 박종훈;최규진;김상현
    • 유기물자원화
    • /
    • 제22권2호
    • /
    • pp.50-56
    • /
    • 2014
  • 일반적으로 도금 폐수를 비롯한 산업 폐수 내 중금속 처리에 적용되는 응집-침전은 응집제의 비용과 침전 효율의 불안정성이라는 한계가 존재한다. 본 연구에서는 수산화물 생성-분리막 공정을 전제로 하여, pH와 교반조건에 따른 수용액 상의 중금속 제거 효율과 생성된 수산화물의 입도 분포를 고찰하였다. pH별 실험 결과, pH 9-10에서 최적의 중금속 제거 효율이 확인되었으며, 무기응집제인 $FeCl_3$의 투입은 오히려 제거 효율을 저하시켰다. 완속교반 시간 및 강도는 70 rpm, 20 min 조건이 최대 효율을 보였으며 Cu, Ni, Zn 모두 청정 지역 기준 폐수 배출 기준을 만족하였다. 나타났다. 생성된 중금속 수산화물의 입도 분석을 수행한 결과, 입자의 99.9 %가 $2{\mu}m$ 이상이었다.

A Novel Anticoagulant Protein from Scapharca broughtonii

  • Jung, Won-Kyo;Je, Jae-Young;Kim, Hee-Ju;Kim, Se-Kwon
    • BMB Reports
    • /
    • 제35권2호
    • /
    • pp.199-205
    • /
    • 2002
  • An anticoagulant protein was purified from the edible portion of a blood ark shell, Scapharca broughtonii, by ammonium sulfate precipitation and column chromatography on DEAE-Sephadex A-50, Sephadex G-75, DEAE-Sephacel, and Biogel P-l00. In vitro assays with human plasma, the anticoagulant from 'S. broughtonii, prolonged the activated partial thromboplastin time (APTT) and inhibited the factor LX in the intrinsic pathway of the blood coagulation cascade. But, the fibrin plate assay did not show that the anticoagulant is a fibrinolytic protease. The molecular mass of the purified S. broughtonii anticoagulant was measured to be about 26.0kDa by gel filtration on a Sephadex G-75 column and SDS-PAGE under denaturing conditions. The optimum activity in the APTT assay was exhibited at pH 7.0-7.5 and $40-45^{\circ}C$ in the presence of $Ca^{2+}$.

정수처리에서 암모니아성질소 제거를 위한 제올라이트 여과 (Zeolite Filtration for Ammonium Nitrogen Removal in Drinking Water Treatment)

  • 김우항;김충환
    • 한국환경과학회지
    • /
    • 제12권3호
    • /
    • pp.281-286
    • /
    • 2003
  • This study was conducted to evaluate the feasibility of ammonia removal by zeolite adsorption in drinking water treatment. In generally, drinking water treatment process is conducted coagulation/flocculation, sedimentation, sand filtration and disinfection. We tested feasibility with two method, one is powdered zeolite dosing to coagulation tank and the other is to substitute granular zeolite for sand of sand filter. In powdered zeolite test, raw water is used tap water with putting of 2 mg/l of NH$_4$$\^$+/-N. Filtration of granular zeolite was conducted with 80 cm of effective column high and 120 m/d of flow rate. At above 100 mg/1 of zeolite dosage, ammonia concentration was decreased below 0.5 mg/l of NH$_4$$\^$+/-N in powdered zeolite test. But, turbidity was increased to 30 NTU by powdered zeolite dosage. That turbidity was scarcely decreased in generally coagulant using condition in drinking water treatment. In granular zeolite test, ammonia was not detected in treated water until 8 days. This result suggest that using of granular zeolite in sand filter could be removal ammonia in winter. But we need regeneration at zeolite filtration for ammonia removal. So, it is to make clear that zeolite regeneration ability was compared KCl with NaCl. The result reveal that KCl was more excellent than NaCl. Optimum regeneration concentration of KCl was revealed 100 mM. Regeneration efficient was not increased at pH range 10∼12.5.

폐 철광산 주변 비소로 오염된 토양에 대한 연속 세척기법의 적용 (Sequential Washing Techniques for Arsenic-Contaminated Soils near the Abandoned Iron-Mine)

  • 황정성;최상일;한상근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제10권1호
    • /
    • pp.58-64
    • /
    • 2005
  • 본 연구는 플럭 형성 비소 오염토양에 대한 토양세척기법 적용시 최적의 운전조건을 도출하고자 하였으며, 대상 시료는 D 폐철광산 토양을 선정하였다. 최적의 cut-off size는 전체 토양 중량에 대하여 약 $94\%$ 정도의 분포를 보이는 0.15 mm ($\#100$체)이었다. 수산화나트륨과 염산 모두 비소 제거에 효과적이었고, 진탕비 (토양[g]:세척용액[mL])는 2가지 세척제에 대하여 1:5가 최적 조건임을 알 수 있었다. 토양세척시 형성되는 플럭에 대하여 비소 농도를 파악한 결과, 여타 pH조건에서보다 pH $5\~6$에서 형성된 플럭의 건조 비소 농도가 $990\~1,086\;mg/kg$ dry solids로 높음을 알 수 있었다. 따라서, 세척효율의 향상 여부를 파악하기 위하여 토양세척시 형성되는 플럭의 제거 유무에 따른 연속 토양세척 실험을 수행하였다. 0.2 M염산을 사용하여 플럭을 제거한 토양을 염산 1 M로 세척한 다음 1 M 수산화나트륨으로 연속 세척한 결과, 비소 농도는 약 1.5 mg/kg dry soil을 보였다. 각 단계마다 발생된 세척유출수기 비소 농도는 약 $2\~3\;mg/L$이었으나, 각각의 세척유출수를 혼합하는 경우 비소 농도가 $50\;{\mu}g/L$ 이하로 감소되었는제 이는 비소가 응집${\cdot}$침전으로 제거되는데 유리한 pH조건으로 변환되기 때문인 것으로 판단된다.

최적 응집을 위한 Streaming Current의 기준값 설정에 관한 연구 (Determination of Set Point of Streaming Current for Optimum Coagulation)

  • 유명진;장미정;박귀수
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.34-41
    • /
    • 2006
  • 본 연구에서는 원수의 수질 변화 중 SC에 대한 영향 인자와 이런 인자가 streaming current(SC) 및 set point(SP)에 미치는 영향 정도를 조사하였다. 서울시 구의 취수장의 전염소 처리되지 않은 원수를 실험에 사용하였다. Pilot scale 실험을 통하여 원수 수질 변화에 따른 SC의 변화와 응집제인 poly aluminium chlorides(PACs)의 변화에 따른 SC의 변화를 알아보았다. 또한, 탁도와 용존유기탄소(dissolved organic carbon, DOC)의 처리 효율에 대한 인자들의 영향에 대하여 평가하였다. 실제 한강 원수를 대상으로 일정 기간 동안 원수의 수질과 SC의 변화를 관찰한 결과, SC와 전기전도도가 높은 상관성을 보임을 알 수 있었다. SC를 기준으로 응집 처리한 결과, 최적 응집 조건으로 대표되는 SC, 즉 SP가 연구기간 동안 우기에서 건기로 변화함에 따라 감소하는 경향을 보였다. 특히 원수의 수질이 저탁도 일 때, 탁도에 비해 전기전도도가 SC에 미치는 영향이 상대적으로 증가하는 것으로 나타났다. 전기전도도가 SC와 SP 그리고 응집에 미치는 영향에 대한 실험을 수행한 결과 전기전도도가 증가할수록 SP는 감소하였고, 단위 SC 증가를 위해 주입된 응집제의 양은 점점 증가하였다. 이상의 결과를 통해 볼 때, 응집 공정의 최적 제어를 위해 SC를 이용한 응집 제어는 매우 효율적으로 수행할 수 있었으며, 특히 SP 설정을 위해서는 원수의 수질 특히 전기전도도의 실시간 측정을 고려할 필요가 있는 것으로 나타났다.

간수+염화일철을 이용한 염색폐수 색도처리에 관한 연구 (A Study on Color Treatment of Dyeing Wastewater with Bittern+Iron(II) chloride)

  • 김만구;서명포
    • 한국염색가공학회지
    • /
    • 제12권3호
    • /
    • pp.218-223
    • /
    • 2000
  • Color removal of dyeing wastewater is becoming more important due to intensive limitation on color unit of effluent water, so this study was to investigate an efficient color removal of dyeing wastewater. We found that bittern+iron chloride(II) inorganic coagulant developed by Kabool research center is much higher than any other inorganic coagulants for color removal. Optimum pH of this coagulant was 10.5 and removed more than 90% for color removal efficiency. The results showed that COD and color unit of effluent water was average 60mg/L and 200~250 units when continuous activated sludge test after coagulation with this coagulant has done. From the results of the experiments, the application of bittern+iron chloride(II) inorganic coagulant can save the operating cost of wastewater treatment plants.

  • PDF