• 제목/요약/키워드: Optimizing Simulation

검색결과 405건 처리시간 0.024초

조립 방향 자동 판별 및 조립 순서 자동 수정 시스템 개발 (Development of Automatic Selection of Assembly Direction and Assembly Sequence Correction System)

  • 박홍석;박진우
    • 한국CDE학회논문집
    • /
    • 제18권6호
    • /
    • pp.417-427
    • /
    • 2013
  • Assembly direction is used in order to confirm the generated assembly sequences in an automatic assembly sequence planning system. Moreover, assembly sequence planners can ascertain the feasibility of a sequence during simulation with assembly direction based in a CAD environment. In other words, assembly direction is essential for sequence optimizing and automatic generation. Based on the importance of assembly direction, this paper proposes a method to select the best direction for the generated assembly sequence using disassembly simulation and geometrical common area between assembled parts. Simultaneously, this idea can be applied to verify the generated assembly sequence. In this paper, the automatic selection of assembly direction and sequence correction system is designed and implemented. The developed algorithms and the implemented system are verified based on case study in the CAD environment.

CONTINUOUS-TIME MARKOV MODEL FOR GERIATRIC PATIENTS BEHAVIOR. OPTIMIZATION OF T도 BED OCCUPANCY AND COMPUTER SIMULATION

  • Gorunescu, Marina;Gorunescu, Florin;Prodan, Augustin
    • Journal of applied mathematics & informatics
    • /
    • 제9권1호
    • /
    • pp.185-195
    • /
    • 2002
  • Previous research has shown that the flow of patients around departments of geriatric medicine and ex-patients in the community may be-modelled by the application of a mixed-exponential distribution. In this proper we considered a ave-compartment model using a continuous-time Markov process to describe the flow of patients. Using a M/ph/c queuing model, we present a way of optimizing the number of beds in order to maintain an acceptable delay probability a sufficiently low level. Finally, we constructed a Java computer simulation, using data from St George's Hospital, London.

자동창고 시스템의 최적안 도출을 위한 모의실험적 연구 (A Simulation Study for Optimizing the Functionality of an Automated Storage and Retrieval System)

  • 김문기
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.505-511
    • /
    • 2014
  • The functional role of warehouses in modern industry is changing from an established concept of storage to a concept of circulation. The target of this study is to improve the stacker crane's efficiency for the internal operations of the Automated Storage and Retrieval System (AS/RS). Eight operating schemes are proposed under the combination of three conditions, namely, the storing method, the layout type, and the sequence of command execution. The moving distance of the stacker crane is calculated using the same gateway data through a simulation based on a C# program. The optimal operating scheme is proposed based on the analyzed simulation results. In conclusion, the combination of conditions of random storage, two-way type warehouse, and dual command execution elicits optimum results in travel efficiency for the stacker crane.

Simulation Study of Injection-Molded Light Guide Plates for Improving Luminance Uniformity Based on the Measured Replication Quality of Micro-Patterns for LED TV Backlight

  • Joo, Byung-Yun;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.159-164
    • /
    • 2015
  • In the injection-molded light guide plate the replication quality, i.e. the reproduction accuracy, of micro-patterns should be high and uniform over the entire surface area. However technical difficulty in meeting the necessary replication quality arises as the plate size becomes large for TV applications. We propose a simulation technique to optimize the distribution of micro-patterns on a 55-inch injection molded light guide plate considering non-ideal replication quality of micro-patterns. The luminance uniformity could be improved by more than 16% by optimizing the pattern distribution in spite of the same replication quality.

An innovative CAD-based simulation of ball-end milling in microscale

  • Vakondios, Dimitrios G.;Kyratsis, Panagiotis
    • Advances in Computational Design
    • /
    • 제5권1호
    • /
    • pp.13-34
    • /
    • 2020
  • As small size and complex metal machining components demand increases, cutting processes in microscale become necessary. Ball-end milling is a commonly used finishing process, which nowadays can be applied in the microscale size. Surface quality and dimensional accuracy are two basic parameters that affect small size components in their assembly and functionality. Thus, good quality can be achieved by optimizing the cutting conditions of the procedure. This study presents a 3D simulation model of ball-end milling in microscale developed in a commercial CAD software and its optical and computing results. These carried out results are resumed to surface topomorphy, surface roughness, chip geometry and cutting forces calculations that arising during the cutting process. A great number of simulations were performed in a milling machine centre, applying the discretized kinematics of the procedure and the final results were compared with measurements of Al7075-T651 experiments.

Improvement of flood simulation accuracy based on the combination of hydraulic model and error correction model

  • Li, Li;Jun, Kyung Soo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.258-258
    • /
    • 2018
  • In this study, a hydraulic flow model and an error correction model are combined to improve the flood simulation accuracy. First, the hydraulic flow model is calibrated by optimizing the Manning's roughness coefficient that considers spatial and temporal variability. Then, an error correction model were used to correct the systematic errors of the calibrated hydraulic model. The error correction model is developed using Artificial Neural Networks (ANNs) that can estimate the systematic simulation errors of the hydraulic model by considering some state variables as inputs. The input variables are selected using parital mutual information (PMI) technique. It was found that the calibrated hydraulic model can simulate flood water levels with good accuracy. Then, the accuracy of estimated flood levels is improved further by using the error correction model. The method proposed in this study can be used to the flood control and water resources management as it can provide accurate water level eatimation.

  • PDF

로봇 중심 FMC에서 최적 로봇 서비스 이동정책을 위한 연구 (Optimizing Robot's Service Movement in a Robot-Centered FMC)

  • 박양병
    • 한국시뮬레이션학회논문지
    • /
    • 제1권1호
    • /
    • pp.55-63
    • /
    • 1992
  • This paper presents a simulation based analysis of a service robot operating in a robot-centered FMC, in which the robot is located at the approximate center of the cell and the machines are arranged in a partial circle around it. The robot's function is to locate and service the parts which require a series of unloading, moving, and loading operations. The main purpose of the analysis is to determine the best movement decision for the robot's arm in each instance. The results from the study, based on both statistical and nonstatistical analysis suggest the best policy for the robot's arm's movement that holds promise for application to the robot-centeredFMC.

  • PDF

Patient Flow Optimization for Outpatient Department Using Discrete-Event Simulation

  • Dieu, Xuan-Manh;Hoang, Huu-Trung;Kim, Jung Eon;Kim, Hoon;Park, Junseok;Hwang, Won-Joo
    • 한국멀티미디어학회논문지
    • /
    • 제22권7호
    • /
    • pp.804-814
    • /
    • 2019
  • The patient's waiting time and length of stay have been reported as a factor decreasing their satisfaction in the hospital, especially in developing countries. This paper focuses on modeling hospital's outpatient department workflow in a developing country and optimizing the patient waiting time as well as total length of stay. By using discrete-event simulation, many alternative scenarios have raised, such as adding more working time, altering human resources, and adjusting the staff's responsibility, those scenarios will be examined to explore better settings for the hospital. The results show that possible to achieve a 9.6% reduction in patient total length of stay and it could be accomplished without adding more resources to the hospital.

An Optimized Time-synchronization Method for Simulator Interworking

  • Kwon, Jaewoo;Kim, Jingyu;Woo, Sang Hyo Arman
    • 한국멀티미디어학회논문지
    • /
    • 제22권8호
    • /
    • pp.887-896
    • /
    • 2019
  • In this paper, we discuss an optimization approach for time-synchronizations in networked simulators. This method is a sub-technology that is required to combine heterogeneous simulators into a single simulation. In previous time-synchronization studies, they had built a network system among networked simulators. The network system collects network packets and adds time-stamps to the networked packets based on the time that occurs in events of simulation objects in the individual simulators. Then, it sorts them in chronological order. Finally, the network system applies time-synchronization to each simulator participating in interworking sequentially. However, the previous approaches have a limitation in that other participating simulators should wait for while processing an event in a simulator in a time stamp order. In this paper, we attempt to solve the problem by optimizing time-synchronizations in networked simulation environments. In order to prove the practicality of our approach, we have conducted an experiment. Finally, we discuss the contributions of this paper.

인체 근골격 시뮬레이션을 활용한 인체 보행 시 외골격의 고관절 굴곡/신장 토크 최적화 (Optimization of Hip Flexion/Extension Torque of Exoskeleton During Human Gait Using Human Musculoskeletal Simulation)

  • 강혜선;김진현
    • 로봇학회논문지
    • /
    • 제18권1호
    • /
    • pp.117-121
    • /
    • 2023
  • Research on walking assistance exoskeletons that provide optimized torque to individuals has been conducted steadily, and these studies aim to help users feel stable when walking and get help that suits their intentions. Because exoskeleton auxiliary efficiency evaluation is based on metabolic cost savings, experiments on real people are needed to evaluate continuously evolving control algorithms. However, experiments with real people always require risks and high costs. Therefore, in this study, we intend to actively utilize human musculoskeletal simulation. First, to improve the accuracy of musculoskeletal models, we propose a body segment mass distribution algorithm using body composition analysis data that reflects body characteristics. Secondly, the efficiency of most exoskeleton torque control algorithms is evaluated as the reduction rate of Metabolic Cost. In this study, we assume that the torque minimizing the Metabolic Cost is the optimal torque and propose a method for obtaining the torque.