• Title/Summary/Keyword: Optimizer

Search Result 304, Processing Time 0.024 seconds

Framework Switching of Speaker Overlap Detection System (화자 겹침 검출 시스템의 프레임워크 전환 연구)

  • Kim, Hoinam;Park, Jisu;Cha, Shin;Son, Kyung A;Yun, Young-Sun;Park, Jeon Gue
    • Journal of Software Assessment and Valuation
    • /
    • v.17 no.1
    • /
    • pp.101-113
    • /
    • 2021
  • In this paper, we introduce a speaker overlap system and look at the process of converting the existed system on the specific framework of artificial intelligence. Speaker overlap is when two or more speakers speak at the same time during a conversation, and can lead to performance degradation in the fields of speech recognition or speaker recognition, and a lot of research is being conducted because it can prevent performance degradation. Recently, as application of artificial intelligence is increasing, there is a demand for switching between artificial intelligence frameworks. However, when switching frameworks, performance degradation is observed due to the unique characteristics of each framework, making it difficult to switch frameworks. In this paper, the process of converting the speaker overlap detection system based on the Keras framework to the pytorch-based system is explained and considers components. As a result of the framework switching, the pytorch-based system showed better performance than the existing Keras-based speaker overlap detection system, so it can be said that it is valuable as a fundamental study on systematic framework conversion.

XQuery Query Rewriting for Query Optimization in Distributed Environments (분산 환경에 질의 최적화를 위한 XQuery 질의 재작성)

  • Park, Jong-Hyun;Kang, Ji-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.3
    • /
    • pp.1-11
    • /
    • 2009
  • XQuery query proposed by W3C is one of the standard query languages for XML data and is widely accepted by many applications. Therefore the studies for efficient Processing of XQuery query have become a topic of critical importance recently and the optimization of XQuery query is one of new issues in these studies. However, previous researches just focus on the optimization techniques for a specific XML data management system and these optimization techniques can not be used under the any XML data management systems. Also, some previous researches use predefined XML data structure information such as XML schema or DTD for the optimization. In the real situation, however applications do not all refer to the structure information for XML data. Therefore, this paper analyzes only a XQuery query and optimize by using itself of the XQuery query. In this paper, we propose 3 kinds of optimization method that considers the characteristic of XQuery query. First method removes the redundant expressions described in XQuery query second method replaces the processing order of operation and clause in XQuery query and third method rewrites the XQuery query based on FOR clause. In case of third method, we consider FOR clause because generally FOR clause generates a loop in XQuery query and the loop often rises to execution frequency of redundant operation. Through a performance evaluation, we show that the processing time for rewritten queries is less than for original queries. also each method in our XQuery query optimizer can be used separately because the each method is independent.

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

An Application-Specific and Adaptive Power Management Technique for Portable Systems (휴대장치를 위한 응용프로그램 특성에 따른 적응형 전력관리 기법)

  • Egger, Bernhard;Lee, Jae-Jin;Shin, Heon-Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.8
    • /
    • pp.367-376
    • /
    • 2007
  • In this paper, we introduce an application-specific and adaptive power management technique for portable systems that support dynamic voltage scaling (DVS). We exploit both the idle time of multitasking systems running soft real-time tasks as well as memory- or CPU-bound code regions. Detailed power and execution time profiles guide an adaptive power manager (APM) that is linked to the operating system. A post-pass optimizer marks candidate regions for DVS by inserting calls to the APM. At runtime, the APM monitors the CPU's performance counters to dynamically determine the affinity of the each marked region. for each region, the APM computes the optimal voltage and frequency setting in terms of energy consumption and switches the CPU to that setting during the execution of the region. Idle time is exploited by monitoring system idle time and switching to the energy-wise most economical setting without prolonging execution. We show that our method is most effective for periodic workloads such as video or audio decoding. We have implemented our method in a multitasking operating system (Microsoft Windows CE) running on an Intel XScale-processor. We achieved up to 9% of total system power savings over the standard power management policy that puts the CPU in a low Power mode during idle periods.