• 제목/요약/키워드: Optimized Coagulation

검색결과 20건 처리시간 0.022초

Production of Eco-friendly Aminotosan® Fertilizer from Waste Livestock Blood using Chitosan Coagulation

  • Kim, Hyeon-Jeong;Shin, Myung-Seop;Jeon, Yong-Woo
    • 한국토양비료학회지
    • /
    • 제48권6호
    • /
    • pp.724-730
    • /
    • 2015
  • The aim of this study was to produce Aminotosan$^{(R)}$ fertilizer using optimized chitosan coagulant from waste livestock blood. Amino-acid fertilizer was produced by pretreated livestock blood. Chitosan coagulant was aggregated with amino-acid fertilizer to produce Aminotosan$^{(R)}$. Optimized coagulation conditions were set using chitosan coagulant such as 10% citric acid and 500 ppm chitosan coagulant by analysis of CST and TTF. The efficiency of coagulation by chitosan coagulant under the optimal conditions was better than chemical coagulants. After solid/liquid separation for coagulated amino-acid fertilizer, Aminotosan$^{(R)}$ fertilizer which added eco-friendly and aesthetic functions was produced.

Optimization of coagulation conditions for pretreatment of microfiltration process using response surface methodology

  • Jung, Jungwoo;Kim, Yoon-Jin;Park, Youn-Jong;Lee, Sangho;Kim, Dong-ha
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.223-229
    • /
    • 2015
  • The application of coagulation for feed water pretreatment prior to microfiltration (MF) process has been widely adopted to alleviate fouling due to particles and organic matters in feed water. However, the efficiency of coagulation pretreatment for MF is sensitive to its operation conditions such as pH and coagulant dose. Moreover, the optimum coagulation condition for MF process is different from that for rapid sand filtration in conventional drinking water treatment. In this study, the use of response surface methodology (RSM) was attempted to determine coagulation conditions optimized for pretreatment of MF. The center-united experimental design was used to quantify the effects of coagulant dose and pH on the control of fouling control as well as the removal organic matters. A MF membrane (SDI Samsung, Korea) made of polyvinylidene fluoride (PVDF) was used for the filtration experiments. Poly aluminum chloride (PAC) was used as the coagulant and a series of jar tests were conducted under various conditions. The flux was $90L/m^2-h$ and the fouling rate were calculated in each condition. As a result of this study, an empirical model was derived to explore the optimized conditions for coagulant dose and pH for minimization of the fouling rate. This model also allowed the prediction of the efficiency of the coagulation efficiency. The experimental results were in good agreement with the predictions, suggesting that RSM has potential as a practical method for modeling the coagulation pretreatment for MF.

Chemical coagulation and sonolysis for total aromatic amines removal from anaerobically pre-treated textile wastewater: A comparative study

  • Verma, Akshaya K.;Bhunia, Puspendu;Dash, Rajesh R.
    • Advances in environmental research
    • /
    • 제3권4호
    • /
    • pp.293-306
    • /
    • 2014
  • The present study primarily focuses on the evaluation of the comparative effect of chemical coagulation and ultrasonication for elimination of aromatic amines (AAs) present in anaerobically pretreated textile wastewater containing different types of dyes including azo dyes. Color and COD reduction was also monitored at the optimized conditions. The production of AAs was measured spectrophotometrically in the form of total aromatic amines (TAAs) and also verified with high performance liquid chromatography (HPLC) selectively. A composite coagulant, magnesium chloride (MC) aided with aluminium chlorohydrate (ACH) in an equal ratio (MC + ACH) was utilized during the coagulation process, which yielded 31% of TAAs removal along with 85% of color and 52% of COD reduction. At optimized power (200 W) and sonication time (5 h), an appreciable TAAs degradation efficiency (85%) was observed along with 51% color reduction and 62% COD removal using ultrasonication. The chromatographic data indicate that sulphanilic acid and benzidine types of aromatic amines were produced after the reductive cleavage of utilized textile dyes, which were effectively mineralized after ultrasonication. The degradation followed the first order kinetics with a correlation coefficient ($R^2$) of 0.89 and a first-order kinetic constant (k) of $0.0073min^{-1}$.

Cellulose acetate membrane preparation by phase inversion to estimate optimized parameters and its performance study

  • Katariya, Heena N;Patel, Tejal M
    • Membrane and Water Treatment
    • /
    • 제13권3호
    • /
    • pp.139-145
    • /
    • 2022
  • Development in advanced separation processes leads to the significant advancement in polymeric membrane preparation methodology. Therefore, present research investigated the preparation and characterization of cellulose acetate membrane by phase inversion separation method to determine optimized operating parameters. Prepared CA membrane's performance was been analyzed in terms of % rejection and flux. Investigation was conducted to study effect of different parameters such as polymer concentration, evaporation rate, thickness of film, coagulation bath properties, temperature of polymer solution and of the coagulation bath etc. CA membrane was fabricated by taking polymer concentration 10wt% and 11wt% with zero second evaporation time and varying film thickness over non-woven polyester fabric. Effect of coagulation bath temperature (CBT) and casting solution temperature were also been studied. The experimental results from SEM showed that the surface morphology had been changed with polymer r concentration, coagulation bath and casting solution temperature, etc. Lower polymer concentration leads to lower precipitation time giving porous membrane. The prepared membrane was tested for advanced waste water treatment of relevant effluent stream in pilot plant to study flux and rejection behavior of the membrane.

난분해성 후렉소잉크 폐수중 유기물 및 색도제거를 위한 철촉매 공기산화 공정의 적용 (Application of Iron-Catalyzed Air Oxidation Process for Organics and Color Removals in Recalcitrance Flexographic Inks Wastewater)

  • 조용덕;윤현희;박상준;김종성;이상화
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.487-498
    • /
    • 2006
  • The oxidation processes of metal catalysis were practically applied into the flexographic inks wastewater treatment to derive the most effective and economical system among all the processes of iron-salts coagulation, iron-catalyzed air oxidation, and coagulation followed by biological treatment. The iron concentration and pH were optimized as $2.8{\times}10^{-3}mol$ and 5.5~6.0, respectively, for all the oxidation processes. At the optimal reaction conditions, the removal efficiencies of $TCOD_{Mn}$ and Color were as follows for the respective process: i) 75% $TCOD_{Mn}$ and 77% Color removals for iron-salts coagulation, ii) 91% TCODMn and 90% Color removals for iron-catalyzed air oxidation, iii) 74~92% $TCOD_{Mn}$ and 81~90% Color removals for coagulation followed by biological treatment. Based on the economical and technological aspects, iron-catalyzed air oxidation was confirmed as the most effective process in the treatment of industrial wastewater.

응집침전공정에서 수온, 응집제 종류, 전염소 주입에 따른 크립토스포리 디움과 지아디아 제거 효율 변화에 관한 연구 (The Effects of Temperature, Coagulants, and Pre-chlorination on the Removal of Cryptosporidium and Giardia by Coagulation Process)

  • 박상정;정영희;정현미
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.531-538
    • /
    • 2007
  • The effects of temperature, coagulants and pre-chlorination on the removal of turbidity and pathogenic protozoa by coagulation process were investigated using jar test of lab scale. In room temperature ($25^{\circ}C$), protozoa were removed over 1.0log at the proper concentration range of coagulants, and up to over 2log at the optimal concentration of coagulants. Considering the 1.5log target removal for Giardiain the processes of coagulation, sedimentation, and filtration, this results implies that the target could be satisfied. However, the removal of protozoa and turbidity was reduced, and optimal PAC concentration was narrowed in low turbidity and cold temperature ($5^{\circ}C$). These results suggest that the drop of coagulation efficiency may be occurred in winter if the conditions are not optimized. Despite the effect of water temperature, the relation of turbidity and protozoa removal appeared to be good. The various kinds of coagulants did not significantly affected for removals of turbidity and protozoa when the concentrations of $Al_2O_3$ were considered. Prechlorination did not increase or decrease the removal of turbidity and protozoa in optimum condition at room temperature, pH 7, 15mg/L of PAC concentration.

먹는물에서 분리막의 역할 (Membrane Roles in Potable Water Treatment)

  • Maeda, Yasushi
    • 멤브레인
    • /
    • 제6권4호
    • /
    • pp.196-202
    • /
    • 1996
  • In this paper several advantage of RO/NF technologies have been described. However, it should be noted that membrane technology does not solve all the water treatment problems encountered in municipalities. Membranes can provide effective and highly optimized solutions when integrated with conventional technologies such as coagulation, sand filtration, and activated carbon treatments.

  • PDF

상수원수의 혼화 및 응집 조건에 따른 DAF pump 장치의 부상분리효율 (Flotation Efficiency of the DAF Pump System for Mixing and Coagulation Conditions in Raw Drinking Water)

  • 안갑환;이창한
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.639-645
    • /
    • 2011
  • This study found that flotation efficiencies for removing algae and micro particles in raw water were optimized on mixing intensity and time of the mixing and flocculation conditions with a continuous DAF system. It is more efficient for mixing intensity at 23.1 $s^{-1}$ and time at 660 s(Gt value : 15246) to float flocculated floc with the raw water in M water treatment plant. Flotation efficiency was more than about 0.9 when operated pressure and A/S ratio were sustained at 5 $kg_f{\cdot}cm^{-2}$ and up to 0.056 $mL{\cdot}mg^{-1}$. The continuous DAF system made by the study could be continuously operated for 20 days and sustained not exceeding 4 NTU with raw water with low turbidity(13.4~9.8 NTU).

CO2 주입에 의한 pH 조정이 정수장 응집효율 및 알루미늄 용출에 미치는 영향 (Effect of pH Adjustment by CO2 on Coagulation and Aluminum Elution in Water Treatment)

  • 이길성;김민채;권재국;서규태
    • 대한환경공학회지
    • /
    • 제35권1호
    • /
    • pp.17-22
    • /
    • 2013
  • 본 연구는 조류 개체 수 증가로 pH가 급격하게 상승한 원수가 정수장으로 유입될 때 pH 조정을 위해 사용하는 이산화탄소($CO_2$) 주입이 응집효율 및 용존 알루미늄 농도변화에 미치는 영향을 고찰하였다. 응집제 1 mg/L에 주입에 따른 pH 감소는 LAS -0.0384, PAC -0.0254, A-PAC -0.0201, PACS2 -0.0135로 나타났다. 용존 알루미늄 농도는 pH 7.44에서 0.02 mg/L, pH 7.96에서 0.07 mg/L, pH 8.16에서 0.12 mg/L, pH 8.38에서 0.39 mg/L로 응집공정의 pH 증가에 따라 용존 알루미늄 농도가 증가하는 것으로 나타났다. 여기서 주목할 점은 급속 교반 후 pH 8.0을 초과할 때부터 용존 알루미늄 농도는 급격하게 증가하는 것이다. 그러므로 높은 pH의 원수가 유입되는 정수장에서 알루미늄 농도가 먹는 물 수질 기준 만족하기 위해서는 응집공정의 pH가 7.8 이하로 유지되도록 공정관리가 필요하며, 원수 pH가 8.0 이상 유입되는 경우 이산화탄소($CO_2$) 주입으로 pH를 7.3 내외로 일정하게 유지할 수 있었다. 또한 이산화탄소($CO_2$) 주입으로 응집공정에서 pH를 조정함으로써 탁도 및 응집제 절감, 용존 알루미늄 농도 감소 효과를 확인할 수 있었다.