Application to a Multimachine Power System of Power System Stabilizer using Revised Pole Shift Adaptive Control Algorithm (개선된 극점이동 적응제어 알고리즘을 이용한 전력계통 안정화장치의 다기계통 적용)

  • Lee, Sang-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.486-493
    • /
    • 2000
  • This paper presents an application to a multimachine power system of power system stabilizer using revised pole shift adaptive algorithm. Controller parameters are determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameters of controller and overcome the problem of pole placement algorithm, this paper presents pole shift algorithm revised pole shift factor. Also, the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping characteristics. The results tested on a multimachine power system verify that the proposed controller has better dynamic and transient performance than conventional controller.

  • PDF

Control of Slurry Flow Rate in Copper CMP (구리 CMP시 슬러리 Flow Rate의 조절)

  • Kim, Tae-Gun;Kim, Nam-Hoon;Kim, Sang-Yong;Seo, Yong-Jin;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.34-37
    • /
    • 2004
  • Recently advancing mobile communication tools and I.T industry, semiconductor device is requested more integrated, faster operation time and more scaled-down. Because of these reasons semiconductor device is requested multilayer interconnection. For the multilayer interconnection chemical mechanical polishing (CMP) becomes one of the most useful process in semiconductor manufacturing process. In this experiment, we focus on understand the characterize and improve the CMP technology by control of slurry flow rate. Consequently, we obtain that optimal flow rate of slurry is 170ml/min, since optimal conditions are less chemical flow and performance high with good selectivity to Ta. If we apply this results to copper CMP process. it is thought that we will be able to obtain better yield.

  • PDF

Fuel Cell Stack Dynamics Modeling Considering Load Variation (부하의 변화를 고려한 연료전지 스택 동특성 모델링)

  • Ko, Jeong-Min;Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.93-99
    • /
    • 2009
  • In this paper, transient voltage response of Polmer Electrolyte Membrane Fuel Cell (PEMFC) stack is analyzed and voltage dynamic characteristic is modeled for optimal design of power conditioning system (PCS). According that the load is changed, the corresponding operating voltage of fuel cell stack is also varied with a certain deep and rising time due to the chemical and mechanical responses. This transient behavior can affect on the operation with respect of PI gain in controller, duty ratio, capacitor of capacitor and so on. So in this paper the detailed theoretical analysis of transient voltage dynamics is explained and the methodology of dynamic modeling is introduced. In addition, the validity and feasibility of the proposed dynamic model is verified by experimental results under various load conditions.

An Analysis of M/G/1 System with N and T-Policy (N-정책과 T-정책이 적용되는 M/G/1 시스템의 분석)

  • Hur, Sun;Lee, Hun-Gyu;Kim, Jong-Soo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.81-87
    • /
    • 2000
  • As for M/G/1 queueing system, we use various control policies, with which we can optimize the system. Up to now the most widely adopted policies are N-Policy, T-Policy, D-Policy, and so on. The existing researches are largely concerned to find an optimal operation condition or to optimize the system under single policy in M/G/1 system. There are, however, few literatures dealing with multiple control policies at once to enhance the flexibility of the model. In this study, we consider M/G/1 system adopting N-Policy and T-Policy simultaneously. If one of two conditions is satisfied, then, the server starts the service. We call this Min(N,T)-Policy. We find the probability distribution of the number of customers and mean waiting time in steady state and derive a cost function. Next, we seek the $N^*$, optimal threshold under various N values. Finally, we reveal the characteristics of cost function.

  • PDF

Development of Expert System for Optimal Condition of Die and Mold Automatic Polishing (금형자동연마의 최적조건선정 전문가시스템 개발)

  • 이두찬;정해도;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.519-523
    • /
    • 1996
  • The polishing tool unit is developed which can be attached on the machining center and automatic polishing system for die and mold is also established. So, experiments are carried out under the several polishing conditions. The polishing properties of automatic polishing operation such as surface roughness, stock removal and maximum profile valley depth are obtained and analyzed quantitatively for each polishing tool. The purpose of this study is to construct an expert system for optimal condition of die and mold automatic polishing using the knowledge base that is obtained in the polishing experiments and, to verify the feasibility of the expert system through the experiments. Using this expert system, unskilled operators will be able to obtain the knowledge and experience of an expert.

  • PDF

Optimal Construction of Rotary-Linear Induction Motor (회전-리니어 병용 유도전동기의 특성해석)

  • Onuki, Takashi;Jeon, Woo-Jin;Tanabiki, Masamoto;Yoo, Ji-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.130-132
    • /
    • 1997
  • In this paper, we propose a new type of tubular linear induction motor(TLIM) with two-dimensional motion. The proposed motor consists of four short primary LIMs arranged on a same circumference and a common secondary. By adopting independently energized ring-windings to the primary, we can expect the reduction of coil-end region and the freedom of alternating current supply. The secondary conductor is capable of producing anyone of rotary, linear, and helical motions by controlling the phase of supply currents in each primary winding. From the 3-D finite element analysis and the experiment, we derive the feeding conditions to increase the subsidiary rotary-force and an optimal arrangement of primary currents to reduce the number of slot.

  • PDF

Experimental study on the performance of a turbocompound diesel engine with variable geometry turbocharger

  • Yin, Yong;Liu, Zhengbai;Zhuge, Weilin;Zhao, Rongchao;Zhao, Yanting;Chen, Zhen;Mi, Jiao
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.4
    • /
    • pp.332-337
    • /
    • 2016
  • Turbocompounding is a key technology to satisfy the future requirements of diesel engine's fuel economy and emission reduction. A turbocompound diesel engine was developed based on a conventional 11-Liter heavy-duty diesel engine. The turbocompound system includes a power turbine, which is installed downstream of a Variable Geometry Turbocharger (VGT) turbine. The impacts of the VGT rack position on the turbocompound engine performance were studied. An optimal VGT control strategy was determined. Experimental results show that the turbocompound engine using the optimal VGT control strategy achieves better performance than the original engine under all full load operation conditions. The averaged and maximum reductions of the brake specific fuel consumption (BSFC) are 3% and 8% respectively.

Evaluation of Operational Conditions and Power Consumption of a Bioattritor for Enzymatic Saccharification of Uncooked Starch (무증자 전분당화용 분쇄마찰매체 함유 효소반응기의 조작조건과 동력소모의 검토)

  • 이용현;박진서
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.4
    • /
    • pp.349-357
    • /
    • 1989
  • Uncooked starch can be effectively saccharified in an enzyme reaction system containing attrition-milling media. To develope the high efficiency bioattritor, an agitated bead type bioreactor was constructed, and its effectiveness was evaluated. The optimal operation condition of bioattritor was found to be 300 g glass bead/L, 200 rpm, standard type impeller for 220 g/L of uncooked corn starch. The torque under the various operational conditions were also measured. The interrelation-ship between energy consumption for agitation of attrition-milling media and enhanced extent of saccharification of uncooked starch was evaluated, Power consumption was measured to be around 1.53 watt/L under the optimal operation condition. The attrition coupled enzyme reaction system is identified to tie a very excellent energy saying process for saccharification of uncooked starch, and seems to have a bright prospect of industrial application.

  • PDF

The On-Line Application Algorithm of SCOPE Using Time-varying Sensitivities (시변민감도를 이용한 안전도제약 최적조류계산의 On-Line 적용 알고리즘)

  • 김발호;신영균
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.60-67
    • /
    • 2004
  • The recent movement to deregulated and competitive electricity market reacquires new concepts against existing central dispatch in the system operation and pinning. As power systems tend to be operated more closely to their ultimate ratings, the role of SCOPF (Security Constrained Optimal Power flow) is changed and the importance for real-time security inhancement will be more increased i]1 the new and com partitive electricity market. This paper deals with the application of the SCOPF which makes possible the On-Line application. The security margin of power system truly is changed according to the conditions or configuration of power systems, therefore, the sensitivity factor reiated to the security is recalculated and the application should be updated in accordance with the state of power system. The goal of this paper is to obtain proper security through the effluent usage of the sensitivity and to apply this a1gorithm to system operation. The proposed mechanism has been tested on a sample system and the results show more secure conditions against critical contingencies.

Digital Ratio Differential Relaying for Main Protection of Large Generator (대형 발전기 주보호를 위한 디지털 비율차동 계전기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • An AC generator is an important component in producing an electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. It is a need for research of digital generator protection system(DGPS) for the next-generation ECMS and an efficient operation of protection control system in power station. However, most of protection and control system used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, presented ratio differential relaying(RDR) is main protective element in generator protection IED. The fault detection technique, operation zone and setting value of the RDR were studied and, compared with two of the fault detection algorithm. For evaluation performance of the RDR, the data obtained from ATPDraw5.7p4 modeling was used. The proposed methods are shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault.