• Title/Summary/Keyword: Optimal injection dose

Search Result 36, Processing Time 0.03 seconds

Increasing injection frequency enhances the survival of injected bone marrow derived mesenchymal stem cells in a critical limb ischemia animal model

  • Kang, Woong Chol;Oh, Pyung Chun;Lee, Kyounghoon;Ahn, Taehoon;Byun, Kyunghee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.6
    • /
    • pp.657-667
    • /
    • 2016
  • Critical limb ischemia (CLI) is one of the most severe forms of peripheral artery diseases, but current treatment strategies do not guarantee complete recovery of vascular blood flow or reduce the risk of mortality. Recently, human bone marrow derived mesenchymal stem cells (MSCs) have been reported to have a paracrine influence on angiogenesis in several ischemic diseases. However, little evidence is available regarding optimal cell doses and injection frequencies. Thus, the authors undertook this study to investigate the effects of cell dose and injection frequency on cell survival and paracrine effects. MSCs were injected at $10^6$ or $10^5$ per injection (high and low doses) either once (single injection) or once in two consecutive weeks (double injection) into ischemic legs. Mice were sacrificed 4 weeks after first injection. Angiogenic effects were confirmed in vitro and in vivo, and M2 macrophage infiltration into ischemic tissues and rates of limb salvage were documented. MSCs were found to induce angiogenesis through a paracrine effect in vitro, and were found to survive in ischemic muscle for up to 4 weeks dependent on cell dose and injection frequency. In addition, double high dose and low dose of MSC injections increased vessel formation, and decreased fibrosis volumes and apoptotic cell numbers, whereas a single high dose did not. Our results showed MSCs protect against ischemic injury in a paracrine manner, and suggest that increasing injection frequency is more important than MSC dosage for the treatment CLI.

Effects of Intravitreal Centamicin Injection on the Clinically Normal Canine Eye (개에서 초자체내 겐타마이신 주사의 영향)

  • 강선미;이충호;김완희;우흥명;권오경
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.333-336
    • /
    • 2002
  • This experiment was carried out to investigate the optimal dose of intravitreal gentamicin that decreases intraocular pressure effectively and minimizes complications in dog. After inhalation anesthesia, gentamicin was injected intravitreally into the left eyes at doses of 10, 15 and 20 mg with 1 mg dexamethasone, respectively. Sterilized isotonic saline and dexamethasone mixture into the right eyes for control. Six dogs were used in each group. Intraocular pressures were measured using applanation tonometer(Mentore, Tono-Pen) until 5 months after injection of gentamicin. Ocular examinations were performed using direct ophthalmoscopy. The ocular volumes of both eyes were measured. Intraocular pressures of eyes injected with 10. 15 and 20 mg of gentamicin were decreased significantly compared with control eyes. Severe corneal opacity and neovascularization occurred in 20 mg treated group. Intraocular hemorrhage was observed in 3 dogs of 20 mg treated group. Ocular volume was significantly decreased(p <0.05) in 20 mg treated group, compared with 10 and 15 mg treated group. It is considered that intravitreal gentamicin injection at dose of 10 mg or 15 mg decrease intraocular pressure effectively and minimize complications such as corneal opacity, hyphema and phthisis bulbus.

Injection Molded Nano Scale Pattern (사출 성형 공정을 이용한 나노급 패턴 제작)

  • Yoo, Yeong-Eun;Seo, Young-Ho;Choi, Doo-Sun;Lee, Jun-Hyung;Che, Tae-Jin;Hwang, Kyung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.989-992
    • /
    • 2004
  • A new method is proposed to fabricate a reusable qualtz master with order of 100 nm dot pattern on its surface. Some fabrication conditions such as dose are investigated to find optimal condition. This reusable qualtz master is used directly as a stamper to injection mold the dot patterns. Polycarbonate and Polyoxymethylene are used as molding materials and the effect of the mold temperature is also investigated to see the moldabilty of the injection molding for very fine dot features.

  • PDF

Efficacy of Recombinant Erythropoietin from CHO Cells (CHO 세포에서 생산된 재조합 Erythropoietin (EPO)의 약효)

  • 김석준;하병집;이동억;오명석;김달현;박관하;김현수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.4
    • /
    • pp.343-346
    • /
    • 1994
  • In vivo activity of recombinant human erythropoietin (rh-EPO) has been examined using polycythemic model in mice and acute hemorrhage model in rats. The number of reticulocytes in blood stream was increased after a single injection of rh-EPO depending on the dosage of rh-EPO in polycythemy model. It seemed that optimal dose of rh-EPO for polycythemic mice was around 1-10 U/kg. Rh-EPO also showed the effectiveness for increase of reticulocyte numbers both in male and female rats after bleeding. The number of reticulocytes and the change of hemoglobin concentration in the blood stream of normal rats has been examined after injection of rh-EPO. The maximum value of reticulocyte was observed on the 6th day of the injection in these normal rats. In addition, the increase of reticulocyte and the concentration of hemoglobin were dependent on the dosage of rh-EPO. The increase of hemoglobin concentration was continued to the 9th day after injection. In this study, the efficacy of rh-EPO was confirmed in both mice and rats.

  • PDF

Contrast Optimization using of Weight-based Injection Protocol in Pediatric Abdomen CT Examination (소아 복부 CT 검사에서 체중에 기반한 조영제 주입 프로토콜 적용에 따른 조영증강의 최적화)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.575-584
    • /
    • 2021
  • The aim of this study was to achieve optimal portal phase while reducing contrast medium by applying weight-based dose protocol compared to standard fixed dose protocol to performing of pediatric abdominal CT examination. Discovery 750HD (General Electric Medical Systems, Milwaukee, USA) was used, and a total of 167 children consisting of 85 men and 82 women under the age of 18 were studied. The group in which the 300 mgI/ml(Xenetix, Guerbet, France) contrast medium was fixedly injected at twice body weight and the group injected with physiological saline while gradually decreasing the injection amount by 10% while applying the weight-based protocol were distinguished. Also, the CT number and SNR of abdominal organs were compared and evaluated while changing the scan delay time. Subjective image quality of enhancement and beam-hardening artifacts of around the heart was assessed with five-point criterion. The group adapted weight-based protocol with 20% reduction in contrast medium was most similar in contrast enhancement in the group with fixed injection at twice body weight. Furthermore, the group with a delay time of 20% had the highest contrast enhancement effect, and the difference in CT attenuation coefficient from the group scanned immediately after injection of the contrast media. Therefore, the appropriate delay time after injection of the contrast agent increased the contrast enhancement of the parenchymal organ. In addition, the weight-based injection protocol with normal saline reduced artifacts around the heart, and the effect of contrast enhancement could be maintained. In conclusion, it is possible to reduce dosage of contrast media through the application of weight-based injection protocols and appropriate latency, and to characterize optimal portal phase imaging on pediatric abdominal CT.

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

Study on Antibody-enzyme Coupling and Enzyme Immunoassay Methods (효소-항체의 결합 및 효소면역측정 방법의 연구)

  • Jang Sean Il
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.3
    • /
    • pp.874-879
    • /
    • 2004
  • Alakaline phosphatase (ALP)- or horseradish peroxidase (HRP)-antibody conjugate was used frequently on the immunological detection methods such as enzyme-linked immunosobent assay (ELISA), immunobolt, immunohistochemistry. The classical enzyme-antibody coupling method by one-step (direction) injection of glutaraldehyde bring into being disadvantage such as low sensitivity of antigen detection because of homopolymers. This study was modified with the dialysis glutaraldehyde method to provide simple coupling through E-amino residues present in most protein. The dialysis glutaraldehyde coupling effects were better than the classical one-step glutaraldehyde injection in antigen detection of ELISA and immunobolt. Optimal dose of the dialysis glutaraldehyde solution was 0.10-0.25 %. This results suggest that the dialysis glutaraldehyde coupling method can readily applied to antigen detection of in vitro and in vivo.

Epidural Steroid Injection in Korean Pain Physicians: A National Survey

  • Kim, Eun Jung;Moon, Jee Youn;Park, Keun Suk;Yoo, Da Hye;Kim, Yong Chul;Sim, Woo Seog;Lee, Chul Joong;Shin, Hwa Yong;Kim, Jae Hun;Kim, Yeon Dong;Lee, Se Jin
    • The Korean Journal of Pain
    • /
    • v.27 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Background: Epidural steroid injection (ESI) is one of the most common procedures for patients presenting low back pain and radiculopathy. However, there is no clear consensus on what constitutes appropriate steroid use for ESIs. To investigate optimal steroid injection methods for ESIs, surveys were sent to all academic pain centers and selected private practices in Korea via e-mail. Methods: Among 173 pain centers which requested the public health insurance reimbursements for their ESIs and were enrolled in the Korean Pain Society, 122 completed questionnaires were returned, for a rate of 70.5%; also returned were surveys from 39 academic programs and 85 private practices with response rates of 83.0% and 65.9%, respectively. Results: More than half (55%) of Korean pain physicians used dexamethasone for ESIs. The minimum interval of subsequent ESIs at the academic institutions (3.1 weeks) and the private practices (2.1 weeks) were statistically different (P = 0.01). Conclusions: Although there was a wide range of variation, there were no significant differences between the academic institutions and the private practices in terms of the types and single doses of steroids for ESIs, the annual dose of steroids, or the limitations of doses in the event of diabetes, with the exception of the minimum interval before the subsequent ESI.

Decision Algorithm of Natural Algae Coagulant Dose to Control Algae from the Influent of Water Works (정수장 유입조류 전처리를 위한 천연조류제거제(W.H.)의 최적주입농도 결정)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Yoon, Young H.;Ahn, Kwang-Ho;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.482-496
    • /
    • 2016
  • Algal blooms of cyanobacteria (blue-green Algae) due to the eutrophication of rivers and lakes can cause not only the damage by its biological toxins but also the economic loss in drinking water treatment. The natural algae coagulant, a commercial product known as W.H. containing the algicidal and allelopathic material derived from oak, can control algal problems proactively through the coagulation flotation process. However, because there have been no applications of the process for pre-treatment in drinking water plants, we could find no report on the optimum injection dose of W.H.. In this study, we have conducted several sets of jar-tests while changing W.H. dose and concentration of chl-a for (1) Han-river samples and (2) subcultured cyanobacteria samples, and monitored the removal mechanisms of algae intensively. Based on these jar-test results, two linear equations with variables of chl-a and turbidity have been deduced to predict the optimal W.H. dose after the multiple regression analysis using IBM-SPSS. Also, prototypes of automatic control logic have been suggested to inject the optimal W.H. dose promptly in response to the variation of water quality.

The Effect of Low-Intensity Treadmill Exercise on Blood Levels of Glucose, Insulin and Lipids in Streptozotocin-Induced Diabetic Rats (저강도 treadmill 운동이 streptozotocin 유도 당뇨쥐의 혈당, 인슐린 및 지질 농도에 미치는 영향)

  • 김세종;서혜림;고정림;염종우;예정복;이선주;김경환;손원협;장은숙
    • Journal of Life Science
    • /
    • v.14 no.2
    • /
    • pp.245-251
    • /
    • 2004
  • Exercise is beneficial to the diabetic patients and streptozotocin-induced diabetic rat has been used for the study of exercise effect. The purpose of this study was to establish the optimal condition of induction of hyperglycemic diabetic rat using streptozotocin and to examine the preventive effect of treadmill exercise on the diabetic rat before and after streptozotocin injection. Intraperitoneal injection of increasing amount of streptozotocin up to 40 mg/kg dose-responsively induce hyperglycemic diabetic rat and inversely reduced the blood insulin level. Body weight was also gradually reduced with the increasing amount of streptozotocin. Control and diabetic rats exercised for 4 weeks before streptozotocin injection. The exercise was performed in the treadmill for 25 minutes a day and 5 times a week with low intensity (0 degree tilt, 15 m/min velocity). Following streptozotocin injection, the blood glucose level was measured every week and the rat was sacrificed after 4 weeks to measure the concentration of insulin and blood lipids. The blood levels of glucose and insulin was significantly reduced with exercise before streptozotocin injection, while those were not changed after streptozotocin injection. The levels of blood lipids such as total cholesterol, HDL-cholesterol, LDL-cholesterol and triglyceride were close to normal control rats. From this study, researchers found the optimal condition of preparation of streptozotocin-induced hyperglycemic diabetic rat, and the mild treadmill exercise has beneficial effect on preventing hyperglycemia and hyperlipidemia. Thus, even low intensive running prevent not only diabetes but also diabetic vascular complications.