• 제목/요약/키워드: Optimal flow-rate

검색결과 756건 처리시간 0.034초

실험에 의한 직교류홴의 유량 및 소음 분석 (Experimental Study on the Design Parameter Effects on the Flow-rate and the Noise level in a Cross-flow Fan)

  • 안철오;류호선
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.41-48
    • /
    • 1998
  • This study was carried out to investigate the effect of design parameters on the volume flow-rate and the noise level and to finally find the optimal design variables. Eighteen cross-flow fans were designed by the method of orthogonal array, and the flow-rate and the noise level were measured. These data were analyzed by the neural network system. The effects of eight design variables(scroll exit angle, scroll arc length et al.) on the fan performance and the noise level were valuated and discussed. This experiment shows that the design solutions suggested by neural network system may increase its volume flow-rate and reduce noise simultaneously.

  • PDF

실험에 의한 CROSS FLOW FAN 소음 분석 (Experimental study on the design parameter effect on the noise in the cross flow fan)

  • 안철오;류호선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.615-620
    • /
    • 1997
  • The flow rate and the noise level of 18 cross flow fans were measured to analyze the effect of design variables on these and to finally find the optimal design value. These data were analyzed by the Taguchi method and the neural network. The optimal values obtained by the neural network showed good agreements with that by the Taguchi method. The effects of eight design variables on the fan performance and the noise were evaluated and discussed.

  • PDF

소형 기어펌프 최적화 설계를 위한 유동해석 (Flow Analysis for Optimal Design of Small Gear Pump)

  • 이석영;김승철
    • 에너지공학
    • /
    • 제24권1호
    • /
    • pp.88-96
    • /
    • 2015
  • 기어펌프는 단순한 구조를 가지면서도 신뢰성이 높고 작동과 유지가 쉽기 때문에 수력학 장치에 널리 사용된다. 일반적으로 기어펌프는 질량유량과 효율을 고려한 다양한 변수에 의해 설계된다. 본 연구에서는 기어펌프의 최적화 설계를 위해 ANSYS v15.0 CFX 상용프로그램을 사용한 3차원 유동해석을 실시하고 해석결과로부터 설계변수를 선정하도록 하였다. 즉, 기어펌프의 다양한 회전 속도 및 기어 끝단과 하우징 사이의 간극에 대한 질량유량 및 효율을 검토하였으며, 해석 결과로서, 회전 속도가 증가할수록 평균 질량유량 및 효율은 증가하였고, 기어펌프와 하우징의 간격이 증가할수록 평균 질량유량 및 효율은 감소하였다.

분산전원 계통 운용을 위한 3상 최적조류계산 (3 Phase Optimal Power Flow for the Operation of Distributed Generation Systems)

  • 김영곤;송화창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.482_483
    • /
    • 2009
  • This paper presents a method of finding the optimal operating point minimizing a given objective function with 3 phase power flow equations and operational constraints, called 3 phase optimal power flow. 3 phase optimal power flow can provide operation and control strategies for the distribution systems with distributed generation assets, which might be frequently in unbalanced conditions assuming that high penetration rate of renewable energy sources in the systems. As the solution technique, this paper adopts a standard particle swarm optimization (PSO).

  • PDF

마이크로 펌프용 디퓨져/노즐의 유동 특성에 관한 CFD 해석 (CFD Analysis on the Flow Characteristics of Diffuser/Nozzles for Micro-pumps)

  • 김동환;한동석;정시영;허남건;윤석진
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.544-551
    • /
    • 2005
  • The flow characteristics have been numerically investigated for various shapes of the diffuser/nozzles which are used for a valveless micro-pump. The important parameters considered in this study are the throat width ($15\~120\mu$m), the taper angle ($3.15\~25.2^{\circ}$), and the diffuser length ( $600\~4,800\mu$m), and the size of the middle chamber ($1\~16mm^2$). To find the optimal values for these parameters, steady state calculations have been performed assuming the constant pressure difference between the inlet and exit of the flow For the taper angle and the throat width, it is found that there exists an optimum at which the net flow rate is the greatest. The optimal taper angle is in the range of $10\~20^{\circ}$ for all the pressure differences; and the throat width indicates an optimal value near $75\mu$m for the case of 35 kPa pressure difference. The net flow rate is also influenced by the size of the middle chamber. With decreasing chamber size, the net flow rate is reduced because of the interference between two streams flowing into the middle chamber. The unsteady pulsating flow characteristics for a micro-pump with a given diffuser/nozzle shape have been also investigated to show the validity of the steady state parametric study.

플라즈마트론을 이용한 바이오가스 개질로부터 수소생산 (Hydrogen Gas Production from Biogas Reforming using Plasmatron)

  • 김성천;전영남
    • Korean Chemical Engineering Research
    • /
    • 제44권5호
    • /
    • pp.528-534
    • /
    • 2006
  • 고온 플라즈마가 적용된 플라즈마트론을 이용하여 바이오가스 개질을 통해 수소를 생산하는데 있어서 최적 운전 조건에 대해 연구하였다. 음식물 쓰레기의 혐기성 발효조에서 생성된 바이오가스 구성비($CH_4/CO_2$)가 1.03, 1.28, 2.12인 바이오가스로 개질실험을 수행하고, 수소 생산과 메탄 전환율을 향상시키기 위해 바이오가스 유량비, 수증기 유량비, 입력전력 변화와 같은 변수별 연구를 수행하였다. 바이오가스 유량비(biogas/TFR : total flow rate), 수증기 유량비($H_2O/TFR$: total flow rate), 입력전력이 각각 0.32~0.37, 0.36~0.42, 8 kW일 때 메탄의 전환율이 81.3~89.6%인 최적운전조건을 보였다. 이때 합성가스 중의 수소와 일산화탄소의 농도는 27.11~40.23%, 14.31~18.61%이며, 수소 수율은 40.6~61%, 에너지 전환율은 30.5~54.4%, $H_2/CO$ 비는 1.89~2.16이다.

열전달 계수 최대화를 위한 마이크로 증발기의 최적 설계 (Optimal design of a micro evaporator to maximize heat transfer coefficient)

  • 성태종;오대식;서태원;김종원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2097-2101
    • /
    • 2007
  • This paper presents an optimal design of a micro evaporator which maximizes the heat transfer coefficient. Number of gaps, spanwise distance and streamwise distance are selected as the geometric design parameters. Mass flow rate of the refrigerant is selected as the non-geometric design parameter. Temperature at the surface of the heater is measured to valuate the heat transfer coefficient. Nine experiments are conducted using $L_9(3^4)$ orthogonal array. Maximum heat transfer coefficient is 640 W/$m^2K$ at the parameters of 2 gaps, 0.2 mm spanwise distance, 1.0 mm streamwise distance and 0.72 g/s mass flow rate. Among the 3 geometric parameters, the spanwise distance is the most sensitive parameter influencing the heat transfer coefficient. We conduct a second stage of experiment to increase the heat transfer coefficient by reselecting the mass flow rate. We concluded that 0.87 g/s is the optimized flow rate for an active micro cooler resulting in a heat transfer coefficient of 651 W/$m^2K$.

  • PDF

등압법과 T-method를 이용한 공조시스템 배관 설계에 관한 연구 (A Study on the Duct Design of HVAC System Using the Equal Friction Method and the T-method)

  • 박준석;최길환;조대승
    • 대한조선학회논문집
    • /
    • 제46권4호
    • /
    • pp.435-443
    • /
    • 2009
  • Optimal duct design of a HVAC system requires analysis technology to accurately evaluate its pressure losses, flow rate and velocity for making a compromised design among fan capacity and duct size affecting initial manufacturing and operation costs, and noise induced by the HVAC system. In this paper, we carry out initial duct design using the equal friction method. Using the result, the T-method is applied for accurate analysis of flow rate. Then, the duct size is modified using the difference between the required and the calculated flow rate, which can guarantee required flow rate, reduce the pressure unbalance among duct paths and lead to select optimal fan performance. To verify the validity and effectiveness of the proposed design method, an example for HVAC system design including noise analysis is demonstrated.

원자로배수탱크내 Sparger에 대한 유동특성 및 최적설계 (Flow Characteristics and Optimal Design for RDT Sparger)

  • 김광추;박만홍;박경식;이종원
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1390-1398
    • /
    • 1999
  • A numerical analysis for ROT sparger of PWR(Pressurized Water Reactor) is carried out. Computation is performed to investigate the flow characteristics as the change of design factor. As the result of this study, RDT sparger's flow resistance coefficient is K=3.53 at the present design condition if engineering mar&in is considered with 20%, and flow ratio into branch pipe is $Q_s/Q_i=0.41$. Velocity distribution at exit is not uniform because of separation in branch pipe. In the change of inlet flow rate and section area ratio of branch pipe for main pipe, flow resistance coefficient is increased as $Q_s/Q_i$ decreasing, but in the change of branch angle and outlet nozzle diameter of main pipe, flow resistance coefficient is decreased as $Q_s/Q_i$ decreasing. As the change rate of $Q_s/Q_i$ is the larger, the change rate of flow resistance coefficient is the larger. The change rate of pressure loss is the largest change as section area ratio changing. The optimal design condition of sparger is estimated as the outlet nozzle diameter ratio of main pipe is $D_s/D_i=0.333$, the section area ratio is $A_s/A_i=0.2$ and the branch angle is ${\alpha}=55^{\circ}$.

태양열 이용 냉난방 공조시스템 중 전열교환기의 최적운전조건에 관한 연구 (Research on the Optimal Operating Condition of a Total Heat Exchanger in Solar Air-Conditioning System)

  • 김광호;최광환;금종수;김보철;김동규
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.55-62
    • /
    • 1999
  • This study was performed to find out the influence of experimental factors on dehumidification performance and furthermore to suggest an optimal combination of factors of a total heat exchanger in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where the temperature and humidity was maintained constant. In order to find out the contribution ratio of factors on dehumidification performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, the most influential factor on dehumidification performance was the concentration of LiCl(Lithium Chloride) solution. The next influential factors were the temperature of LiCl solution and the air flow rate. The packed layer height, packed material, and flow rate of LiCl solution had no influence on the dehumidification performance under these experimental conditions. Through the three level experiments of $L_{27}(3^{13})$, it was found that the optimal combination was $A_2B_0G_2$(concentration of solution 30 wt%, temperature of solution $15^{\circ}C$, air flow rate $253m^3/h$).

  • PDF