• Title/Summary/Keyword: Optimal extraction conditions

Search Result 364, Processing Time 0.022 seconds

Optimal Extract Condition for the Enhancement of Anticancer Activities of Artemisia princeps Pampanini (강화 사자발쑥의 항암활성 증진을 위한 추출조건의 최적화)

  • Kwon, Min-Chul;Kim, Cheol-Hee;Kim, Hyou-Sung;Lee, Sang-Hee;Chio, Geun-Pyo;Park, Uk-Yeon;You, Sang-Guan;Lee, Hyeon-Young
    • Korean Journal of Medicinal Crop Science
    • /
    • v.15 no.4
    • /
    • pp.233-240
    • /
    • 2007
  • Extractions of Artemisia princeps Pampanini were obtained by using water and ethanol at different temperatures ($60^{\circ}C,\;100^{\circ}C$) with or without ultrasonification process (40 kHz). Yield of ultrasonificated extracts were about 20% higher than that of control group. Cytotoxicity of all conditions through adding 1.0 mg/$m{\ell}$ was below 37%, and treated with ultrasonification group was lower than the other group, about $5{\sim}8%$. $100^{\circ}C$ water extract with ultrasonification was higher anticancer activities as maximum 73% and higher selectivities at concentrations over 0.8 mg/$m{\ell}$. The extracts treated with ultrasonification were higher anticancer activities than the control. Densitometric analysis of bcl-2 revealed that extracts of high anticancer activity had low density. This results suggest that expression of bcl-2 protein by adding of Artemisia princeps Pampanini extracts relative to taking cancer. To conclude, optimum condition for efficient extraction of Artemisia princeps Pampanini is using water with ultrasonification at over $60^{\circ}C$ below $100^{\circ}C$.

A Study on the Image Registration Algorithms for the Accurate Application of Multimodality Image in Radiation Treatment Planning (방사선치료 계획시 다중영상 활용의 정확도 향상을 위한 영상정합 알고리즘 분석)

  • 송주영;이형구;최보영;윤세철;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.209-217
    • /
    • 2002
  • There have been many studies on the application of the reciprocal advantages of multimodality image to define accurate target volume in the Process of radiation treatment planning. For the proper use of the multimodality images, the registration works between different modality images should be performed in advance. In this study, we selected chamfer matching method and mutual information method as most popular methods in recent image registration studies considering the registration accuracy and clinical practicality. And the two registration methods were analyzed to deduce the optimal registration method according to the characteristics of images. Lung phantom of which multimodality images could be acquired was fabricated and CT, MRI and SPECT images of the phantom were used in this study. We developed the registration program which can perform the two registration methods properly and analyzed the registration results which were produced by the developed program in many different images' conditions. Although the overall accuracy of the registration in both chamfer matching method and mutual information method was acceptable, the registration errors in SPECT images which had lower resolution and in degraded images of which data were removed in some part were increased when chamfer matching method was applied. Especially in the case of degraded reference image, chamfer matching methods produce relatively large errors compared with mutual information method. Mutual information method can be estimated as more robust registration method than chamfer matching method in this study because it did not need the prerequisite works, the extraction of accurate contour points, and it produced more accurate registration results consistently regardless of the images' characteristics. The analysis of the registration methods in this study can be expected to provide useful information to the utilization of multimodality images in delineating target volume for radiation treatment planning and in many other clinical applications.

  • PDF

Anti-oxidation, anti-inflammation, anti-wrinkle, and pore-tightening effects of phenolic compounds from Aeonium sedifolium leaves (소인제(Aeonium sedifolium) 잎 유래 phenolic 성분의 항산화, 피부주름생성 억제, 항염증 및 모공 수축 효과)

  • Jung-In Kim;Min-Jae Kim;Ha-Gyeong Jo;Da-Eun Jeong;Hye-Jin Park;Young-Je Cho
    • Food Science and Preservation
    • /
    • v.30 no.2
    • /
    • pp.347-357
    • /
    • 2023
  • The succulent plant Aeonium sedifolium leaves contain several compounds that are of interest for their cosmetic uses on the skin. This study measured the inhibitory effects of enzyme production and antioxidant, astringent effects and skin wrinkles using Aeonium sedifolium leaves (ASL). The total phenolics compounds (TPC) content of ASL under optimal extraction conditions was 34.49 mg/g for hot water extract (ASLW) and 61.64 mg/g for 50% ethanol extract (ASLE). The ASLW and ASLE extracts were freeze-dried, powdered, and used as solids. TPC content, 2,2-diphenyl-1-picrylhydrazy (DPPH) radical scavenging activity, and 2,2'-azinobis (3-ethylben-zothiazoline 6-sulfonate) (ABTS) radical inhibition of the ASL phenolics were tested. The DPPH radical scavenging activities of ASLW and ASLE were tested at a TPC of 100 ㎍/mL. ABTS radical inhibition showed antioxidant activity of 100.00% in ASLW and ASLE, and the antioxidant protection factor of ASLW and ASLE was 1.07 and 1.22, respectively. The thiobarbituric acid-reactive substance (TBARS) inhibitory activity of ASLW and ASLE was 77.00%. The elastase inhibitory activity of ASLE was 69.03%, and collagenase inhibition activity for ASLW and ASLE was 29.82% and 54.76%, respectively. The astringent effect of ASLE was 89.82% at a TPC of 200 ㎍/mL. Thus, we concluded that ASL has the potential as a functional cosmetic ingredient with anti-aging effects on the skin.

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.