• Title/Summary/Keyword: Optimal Pressure Control

Search Result 238, Processing Time 0.026 seconds

Study on Basic Performance Test of Electroosmotic Pump with Porous Glass Slit. (다공성 유리 슬릿 EO펌프 기초 성능 측정 연구)

  • Seo, Sang-Tae;Park, Cheol-Woo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.59-62
    • /
    • 2007
  • The basic concept and preliminary performance results of a miniaturized electroosmotic (EO) pump with diaphragms were included in the present study. The separation of an electroosmotic pumping liquid from a drug using diaphragms is mainly to have a freedom in choosing an electroosmotic pumping liquid and to achieve the optimal drug delivery, and, preferably its precise control. We performed maximum flow rate, maximum pressure, and maximum current measurements with and without diaphragm designs. As a result, the effect of diaphragms on pump performance at the maximum condition is small. However, the presence of diaphragms does not allow indefinite continuous pumping.

  • PDF

A Study on Cutting Characteristics Evaluation of High Speed Feeing Type Laser Cutting M/C (고속 이송 방식 Laser Cutting M/C의 절단성 평가에 관한 연구)

  • 이춘만;임상헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1820-1823
    • /
    • 2003
  • A high speed feeding type laser cutting M/C is developed for precise cutting of sheet metal. This paper has been carried out to obtain cutting characteristics and optimal cutting conditions of the developed high speed feeding type laser cutting M/C by a design of experiments. Cutting speed. laser power. laser duty and gas pressure are control factors for the surface roughness. The major factors affecting the surface roughness and the optimum cutting conditions are studied with minimum experiments using Taguchi method.

  • PDF

A study on the hydrostatic bearing using self-controlled restrictor of grinding wheel spindle (고정밀 연삭기 주축용 가변 면적 자기 보상형 리스트릭터 유정압 베어링에 관한 연구)

  • 조성만
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.425-431
    • /
    • 1999
  • Nowadays development of electric and optical devices needs precision more and more. This study focuses on hydrostatic journal bearing of grinding wheel spindle. It presents theoretical analysis about cylinder type self-controlled restrictor to control flux of oil flowing into pockets around the hydrostatic journal bearing. As a result of this analysis, optimal properties to maximize bearing stiffness such as initial cross distance, supply pressure, diameter of two supply holes, pre-load of spring and clearance between spindle and housing can be obtained. Therefore, by using them it is possible to estimate bearing stiffness and the performance of grinding wheel spindle can be improved.

  • PDF

Failure of Hydraulic Oil Pipe and Transient Vibration (압유배관의 절손 원인 규명과 과도진동)

  • Kim, Yeon-Whan;Lee, Young-Shin;Koo, Jae-Raeyang;Kim, Hee-Su;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1268-1273
    • /
    • 2003
  • This paper presents a case history of piping failures on power plant. The root cause of the failure was defined to set the optimal countermeasures. The failure comes from transient vibration and the 1st stress increased at the hydraulic oil supply system of control valves for high pressure steam turbine.

  • PDF

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

The Effects of Music Therapy on Vital Sign Changes of operational Patients (음악요법이 수술환자의 활력징후 변화에 미치는 영향)

  • 홍순탁
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.3
    • /
    • pp.377-388
    • /
    • 1994
  • The purpose of this study was to determine the effects of music therapy on changes in the vital signs of patients about to undergo an operation. The patients listened to the music at a time when they were feeling preoperative anxiety up until the preanesthesia was given in the operating room. The subjects for this study were selected from sixty patients to undergo operations, who were hospitalized at Dong Eui hospital in Pusan city. They were assigned to two groups, thirty to the experimental group and thirty to the control group. The subjects were from 20 years old to 69 years old, and had no other problem except the one requiring the operation, and no premedication. The data were collected during the period from July 1 to September 30, 1993. The method used in this study was to measure state-anxiety on the ward in the morning of the operation, and vital signs immediately before leaving for the operating room. Vital signs were measured immediately before the anesthesia was given and after the experimental group had listened to the music during the ten minutes needed to prepare the operation setting. The control group just waited during ten mimutes. Vital signs were check again before the anesthesia was given. The data were analyzed by descriptive statistics, mean±SD, p-value, and t-test using the SPSS progrom. The results of this study are : 1. Systolic blood pressure taken in the operating room was elevated, over the level measured on the ward, by 5.00 ± 15.26㎜Hg in experimental group and 18.67±14.56㎜Hg in control group. (t=-3.5496, p=.0008) 2. Diastolic blood pressure was elevated by 6.67±12.95㎜Hg in experimental group and 18.67±12. 79㎜Hg in control group. (t=-3.6100, p=.0006) 3. Pulse was elevated by 2.931±9.44 / min in experimental group and 8.03±8.37 /min in control group. (t=-2.2144, p=.0307) 4. Respiration was elevated by 0.60±1.35 /min in experimental group and 1.57±1.48 /min in control group. (t=-2.6409, p=.0106) 5. Body temperature was down by 0.13±1.91'c in experimental group and elevated by 1.13±1.11'c in control group. (t=-3.1471, p=.0026) Thus, in this study there was a statistically significant difference in the change in the vital signs between the experimental group treated with music therapy and the control group which received no treatment. Because music therapy is valuable to decrease the anxiety of patients facing operations, the result of this study support its effect in relieving anxiety as a valuable nursing intervention. From this study, the following recommendations can be made : First, it is necessary to further study music therapy to develope a better system and determine optimal time. Second, it is necessary that more detailed re-search on measurement of changes in vital signs be done to determine changes over time intervals.

  • PDF

Energy Density Control for the Global Attenuation of Broadband Noise Fields (광대역 잡음의 전역 감쇠를 위한 에너지 밀도 제어)

  • Park, Young-Cheol;Yun, Jeong-Hyeon;Youn, Dae-Hee;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.21-32
    • /
    • 1996
  • The performance of the energy density control algorithm for controlling a broadband noise is evaluated in a one-dimensional enclosure. To avoid noncausality problem of a control filter, which often happens in a frequency domain optimization, analyses presented in this paper are undertaken in the time domain. This approach provides the form of the causally constrained optimal controller. Numerical results are presented to predict the performance of the active noise control system, and indicate that imp개ved global attenuation of the broadband noise can be achieved by minimizing the energy density, rather than the squared pressure. It is shown that minimizing the energy density at a single location yields global attenuation results that are comparable to minimizing the potential energy. Furthermore, unlike the squared pressure control, the energy density control does not demonstrate any dependence on the error sensor location for this one-dimensional field. A practical implementation of the energy-based control algorithm is presented. Results show that the energy density control can be implemented using the two sensor technique with a tolerable margin of performance degradation.

  • PDF

The Effects of Augmented Somatosensory Feedback on Postural Sway and Muscle Co-contraction in Different Sensory Conditions

  • Kim, Seo-hyun;Lee, Kyung-eun;Lim, One-bin;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.27 no.2
    • /
    • pp.126-132
    • /
    • 2020
  • Background: Augmented somatosensory feedback stimulates the mechanoreceptor to deliver information on bodily position, improving the postural control. The various types of such feedback include ankle-foot orthoses (AFOs) and vibration. The optimal feedback to mitigate postural sway remains unclear, as does the effect of augmented somatosensory feedback on muscle co-contraction. Objects: We compared postural sway and ankle muscle co-contraction without feedback (control) and with either of two forms of somatosensory feedback (AFOs and vibration). Methods: We recruited 15 healthy subjects and tested them under three feedback conditions (control, AFOs, vibration) with two sensory conditions (eyes open, or eyes closed and the head tilted back), in random order. Postural sway was measured using a force platform; the mean sway area of the 95% confidence ellipse (AREA) and the mean velocity of the center-of-pressure displacement (VEL) were assessed. Co-contraction of the tibialis anterior and gastrocnemius muscles was measured using electromyography and converted into a co-contraction index (CI). Results: We found significant main effects of the three feedback states on postural sway (AREA, VEL) and the CI. The two sensory conditions exerted significant main effects on postural sway (AREA and VEL). AFOs reduced postural sway to a level significantly lower than that of the control (p = 0.014, p < 0.001) or that afforded by vibration (p = 0.024, p < 0.001). In terms of CI amelioration, the AFOs condition was significantly better than the control (p = 0.004). Vibration did not significantly improve either postural sway or the CI compared to the control condition. There was no significant interaction effect between the three feedback conditions and the two sensory conditions. Conclusion: Lower-extremity devices such as AFOs enhance somatosensory perception, improving postural control and decreasing the CI during static standing.

Automobile Engine Information Display Device Using CAN Communication (캔 통신을 이용한 자동차 엔진 정보 표시장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.203-210
    • /
    • 2019
  • Most cars today use electronic control to control the state of the engine to achieve optimum performance. This study developed a device for maintaining fault diagnosis and optimal vehicle status by displaying the engine information of a car on the screen in real time using can communication. This system displays information generated from the engine to the driver in real time such as engine intake and exhaust temperature, current battery voltage, tire pressure, RPM, DPF collection amount, torque, and horsepower through the OBD2 socket. You can check immediately. It can help you to drive safely by measuring tire pressure and displaying it on the screen, and it provides a mode to set the shift timing to suit your taste. In particular, in the case of diesel engine cars, the problems caused by smoke can adversely affect the performance and environmental pollution. Therefore, the system was developed to display the DPF collection amount on the system screen to prevent environmental pollution and to manage the vehicle efficiently.

Optimization of Gate and Process Design Factors for Injection Molding of Automotive Door Cover Housing (자동차 도어용 커버 하우징의 사출성형을 위한 게이트 및 공정 설계인자의 최적화)

  • Yu, Man-Jun;Park, Jong-Cheon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.7
    • /
    • pp.84-90
    • /
    • 2022
  • The purpose of the cover housing component of a car door is to protect the terminals of the plug housing that connects the electric control unit on the door side to the car body. Therefore, for a smooth assembly with the plug housing and to prevent contaminants from penetrating into the gaps that occur after assembly, the warpage of the cover housing should be minimized. In this study, to minimize the warpage of the cover housing, optimization was performed for design factors related to the mold and processes based on the injection molding simulation. These design factors include gate location, gate diameter, injection time, resin temperature, mold temperature, and packing pressure. To optimize the design factors, Taguchi's approach to the design of experiments was adopted. The optimal combination of the design factors and levels that minimize warpage was predicted through L18-orthogonal array experiments and main effects analysis. Moreover, the warpage under the optimal design was estimated by the additive model, and it was confirmed through the simulation experiment that the estimated result was quite consistent with the experimental result. Additionally, it was found that the warpage under the optimal design was significantly improved compared to both the warpage under the initial design and the best warpage among the orthogonal array experimental results, which numerically decreased by 36.9% and 23.4%, respectively.