The basic concept and preliminary performance results of a miniaturized electroosmotic (EO) pump with diaphragms were included in the present study. The separation of an electroosmotic pumping liquid from a drug using diaphragms is mainly to have a freedom in choosing an electroosmotic pumping liquid and to achieve the optimal drug delivery, and, preferably its precise control. We performed maximum flow rate, maximum pressure, and maximum current measurements with and without diaphragm designs. As a result, the effect of diaphragms on pump performance at the maximum condition is small. However, the presence of diaphragms does not allow indefinite continuous pumping.
Proceedings of the Korean Society of Precision Engineering Conference
/
2003.06a
/
pp.1820-1823
/
2003
A high speed feeding type laser cutting M/C is developed for precise cutting of sheet metal. This paper has been carried out to obtain cutting characteristics and optimal cutting conditions of the developed high speed feeding type laser cutting M/C by a design of experiments. Cutting speed. laser power. laser duty and gas pressure are control factors for the surface roughness. The major factors affecting the surface roughness and the optimum cutting conditions are studied with minimum experiments using Taguchi method.
Proceedings of the Korean Society of Machine Tool Engineers Conference
/
1999.10a
/
pp.425-431
/
1999
Nowadays development of electric and optical devices needs precision more and more. This study focuses on hydrostatic journal bearing of grinding wheel spindle. It presents theoretical analysis about cylinder type self-controlled restrictor to control flux of oil flowing into pockets around the hydrostatic journal bearing. As a result of this analysis, optimal properties to maximize bearing stiffness such as initial cross distance, supply pressure, diameter of two supply holes, pre-load of spring and clearance between spindle and housing can be obtained. Therefore, by using them it is possible to estimate bearing stiffness and the performance of grinding wheel spindle can be improved.
Kim, Yeon-Whan;Lee, Young-Shin;Koo, Jae-Raeyang;Kim, Hee-Su;Bae, Yong-Chae;Lee, Hyun
Proceedings of the KSME Conference
/
2003.11a
/
pp.1268-1273
/
2003
This paper presents a case history of piping failures on power plant. The root cause of the failure was defined to set the optimal countermeasures. The failure comes from transient vibration and the 1st stress increased at the hydraulic oil supply system of control valves for high pressure steam turbine.
The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.
The purpose of this study was to determine the effects of music therapy on changes in the vital signs of patients about to undergo an operation. The patients listened to the music at a time when they were feeling preoperative anxiety up until the preanesthesia was given in the operating room. The subjects for this study were selected from sixty patients to undergo operations, who were hospitalized at Dong Eui hospital in Pusan city. They were assigned to two groups, thirty to the experimental group and thirty to the control group. The subjects were from 20 years old to 69 years old, and had no other problem except the one requiring the operation, and no premedication. The data were collected during the period from July 1 to September 30, 1993. The method used in this study was to measure state-anxiety on the ward in the morning of the operation, and vital signs immediately before leaving for the operating room. Vital signs were measured immediately before the anesthesia was given and after the experimental group had listened to the music during the ten minutes needed to prepare the operation setting. The control group just waited during ten mimutes. Vital signs were check again before the anesthesia was given. The data were analyzed by descriptive statistics, mean±SD, p-value, and t-test using the SPSS progrom. The results of this study are : 1. Systolic blood pressure taken in the operating room was elevated, over the level measured on the ward, by 5.00 ± 15.26㎜Hg in experimental group and 18.67±14.56㎜Hg in control group. (t=-3.5496, p=.0008) 2. Diastolic blood pressure was elevated by 6.67±12.95㎜Hg in experimental group and 18.67±12. 79㎜Hg in control group. (t=-3.6100, p=.0006) 3. Pulse was elevated by 2.931±9.44 / min in experimental group and 8.03±8.37 /min in control group. (t=-2.2144, p=.0307) 4. Respiration was elevated by 0.60±1.35 /min in experimental group and 1.57±1.48 /min in control group. (t=-2.6409, p=.0106) 5. Body temperature was down by 0.13±1.91'c in experimental group and elevated by 1.13±1.11'c in control group. (t=-3.1471, p=.0026) Thus, in this study there was a statistically significant difference in the change in the vital signs between the experimental group treated with music therapy and the control group which received no treatment. Because music therapy is valuable to decrease the anxiety of patients facing operations, the result of this study support its effect in relieving anxiety as a valuable nursing intervention. From this study, the following recommendations can be made : First, it is necessary to further study music therapy to develope a better system and determine optimal time. Second, it is necessary that more detailed re-search on measurement of changes in vital signs be done to determine changes over time intervals.
Park, Young-Cheol;Yun, Jeong-Hyeon;Youn, Dae-Hee;Cha, Il-Whan
The Journal of the Acoustical Society of Korea
/
v.15
no.2
/
pp.21-32
/
1996
The performance of the energy density control algorithm for controlling a broadband noise is evaluated in a one-dimensional enclosure. To avoid noncausality problem of a control filter, which often happens in a frequency domain optimization, analyses presented in this paper are undertaken in the time domain. This approach provides the form of the causally constrained optimal controller. Numerical results are presented to predict the performance of the active noise control system, and indicate that imp개ved global attenuation of the broadband noise can be achieved by minimizing the energy density, rather than the squared pressure. It is shown that minimizing the energy density at a single location yields global attenuation results that are comparable to minimizing the potential energy. Furthermore, unlike the squared pressure control, the energy density control does not demonstrate any dependence on the error sensor location for this one-dimensional field. A practical implementation of the energy-based control algorithm is presented. Results show that the energy density control can be implemented using the two sensor technique with a tolerable margin of performance degradation.
Kim, Seo-hyun;Lee, Kyung-eun;Lim, One-bin;Yi, Chung-hwi
Physical Therapy Korea
/
v.27
no.2
/
pp.126-132
/
2020
Background: Augmented somatosensory feedback stimulates the mechanoreceptor to deliver information on bodily position, improving the postural control. The various types of such feedback include ankle-foot orthoses (AFOs) and vibration. The optimal feedback to mitigate postural sway remains unclear, as does the effect of augmented somatosensory feedback on muscle co-contraction. Objects: We compared postural sway and ankle muscle co-contraction without feedback (control) and with either of two forms of somatosensory feedback (AFOs and vibration). Methods: We recruited 15 healthy subjects and tested them under three feedback conditions (control, AFOs, vibration) with two sensory conditions (eyes open, or eyes closed and the head tilted back), in random order. Postural sway was measured using a force platform; the mean sway area of the 95% confidence ellipse (AREA) and the mean velocity of the center-of-pressure displacement (VEL) were assessed. Co-contraction of the tibialis anterior and gastrocnemius muscles was measured using electromyography and converted into a co-contraction index (CI). Results: We found significant main effects of the three feedback states on postural sway (AREA, VEL) and the CI. The two sensory conditions exerted significant main effects on postural sway (AREA and VEL). AFOs reduced postural sway to a level significantly lower than that of the control (p = 0.014, p < 0.001) or that afforded by vibration (p = 0.024, p < 0.001). In terms of CI amelioration, the AFOs condition was significantly better than the control (p = 0.004). Vibration did not significantly improve either postural sway or the CI compared to the control condition. There was no significant interaction effect between the three feedback conditions and the two sensory conditions. Conclusion: Lower-extremity devices such as AFOs enhance somatosensory perception, improving postural control and decreasing the CI during static standing.
Most cars today use electronic control to control the state of the engine to achieve optimum performance. This study developed a device for maintaining fault diagnosis and optimal vehicle status by displaying the engine information of a car on the screen in real time using can communication. This system displays information generated from the engine to the driver in real time such as engine intake and exhaust temperature, current battery voltage, tire pressure, RPM, DPF collection amount, torque, and horsepower through the OBD2 socket. You can check immediately. It can help you to drive safely by measuring tire pressure and displaying it on the screen, and it provides a mode to set the shift timing to suit your taste. In particular, in the case of diesel engine cars, the problems caused by smoke can adversely affect the performance and environmental pollution. Therefore, the system was developed to display the DPF collection amount on the system screen to prevent environmental pollution and to manage the vehicle efficiently.
Journal of the Korean Society of Manufacturing Process Engineers
/
v.21
no.7
/
pp.84-90
/
2022
The purpose of the cover housing component of a car door is to protect the terminals of the plug housing that connects the electric control unit on the door side to the car body. Therefore, for a smooth assembly with the plug housing and to prevent contaminants from penetrating into the gaps that occur after assembly, the warpage of the cover housing should be minimized. In this study, to minimize the warpage of the cover housing, optimization was performed for design factors related to the mold and processes based on the injection molding simulation. These design factors include gate location, gate diameter, injection time, resin temperature, mold temperature, and packing pressure. To optimize the design factors, Taguchi's approach to the design of experiments was adopted. The optimal combination of the design factors and levels that minimize warpage was predicted through L18-orthogonal array experiments and main effects analysis. Moreover, the warpage under the optimal design was estimated by the additive model, and it was confirmed through the simulation experiment that the estimated result was quite consistent with the experimental result. Additionally, it was found that the warpage under the optimal design was significantly improved compared to both the warpage under the initial design and the best warpage among the orthogonal array experimental results, which numerically decreased by 36.9% and 23.4%, respectively.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.