• Title/Summary/Keyword: Optical temperature sensors

Search Result 220, Processing Time 0.024 seconds

Temperature Sensor Based on Fabry-Perot Interferometer Using a Fiber Optic Patch Cord (광섬유 패치코드를 이용한 Fabry-Perot 간섭계 온도센서)

  • Kim, Ju Ha;Jung, Eun Joo;Kim, Myoung Jin;Hwang, Sung Hwan;Lee, Woo Jin;Kim, Gye Won;An, Jong Bae;Choi, Eun Seo;Rho, Byung Sup
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.110-113
    • /
    • 2014
  • In this paper, we propose and demonstrate a Fabry-Perot interferometer (FPI) optical fiber tip sensor fabricated by a blade-sawing technique using a fiber optic patch cord for high-resolution temperature measurement. The sensor head consists of a short air FP cavity near the tip of a single-mode fiber patch cord tip. The temperature which we can measure is determined through a phase variation of the interference fringes in the reflective spectrum of the sensor. The fiber optic FPI sensor in this work can monitor the environmental temperature very accurately from 40 to $120^{\circ}C$. As a result, the temperature sensitivity is obtained as $38.2pm/^{\circ}C$.

Optical Temperature Sensor Based on the Etched Planar Waveguide Bragg Grating Considering Linear Thermo-optic Effect (평면 광도파로 상의 식각 브래그 격자를 이용한 광온도 센서의 개발)

  • Kook-Chan Ahn;Sang-Mae Lee
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.121-129
    • /
    • 2001
  • This paper demonstrates the development of optical temperature sensor based on the etched planar waveguide Bragg grating. Topics include design and fabrication of the etched planar waveguide Bragg grating, investigation of the grating reflection characteristics, and temperature measurement capabilities. The typical bandwidth and reflectivity of the surface etched grating has been ~0.2nm and ~7%, respectively, at a wavelength of ~1552nm. The temperature-induced wavelength change of the optical sensor is found to be slightly non-linear over ~20$0^{\circ}C$ temperature range. Theoretical models for the grating response of the sensor based on waveguide and plate deformation theories agree with experiments to within acceptable tolerance.

  • PDF

Implementation of Stimulated Brillouin Scattering in Optical Fiber Sensor for Improved Stability by Using Neuro-Fuzzy Theory (뉴로-퍼지 알고리즘을 적용한 광파이버 유도 브릴루앙 산란 센서의 신뢰도 향상에 관한 연구)

  • Hwang, Kyoung-Jun;Yeom, Keong-Tae;Kim, Yong-Kab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.92-97
    • /
    • 2008
  • This is a research to apply 1310nm single-mode optical fiber to a temperature sensor. The existing study of optical fiber sensor is complicated because it was made with various equipment. To vary scattering, the variation of optical frequency is measured by using Bragg(lattice) or pulse generator and also bulk system is created by YAG laser but there were some difficulties creating experimental environment and it was a problem that the stability of measured data was low. The temperature sensor system using the suggested sBs(stimulated Brillouin scattering:sBs) from this research is much more simplified straight-line system. To improve the trust and accuracy of noises from optical frequency and unclear results, it was analysed by using Neuro-Fuzzy algorithm. we tried to get more correct data than existing system. sBs measure that optical frequency changed due to the variation of temperature. The analyzed change rate of outcome by Fuzzy theory is 1.1 MHz.

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

Highly Sensitive Integrated Photonic Temperature Sensor Exploiting a Polymeric Microring Resonator (폴리머 마이크로링 공진기를 이용한 고감도 집적광학형 온도센서)

  • Lee, Hak-Soon;Kim, Gun-Duk;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.224-228
    • /
    • 2008
  • A highly sensitive integrated photonic temperature sensor was proposed and developed incorporating a polymeric microring resonator. The change in the ambient temperature was estimated by observing the shift in the resonant wavelength of the resonator induced via the thermooptic effect. For the purpose of enhancing its sensitivity, the sensor was built by implementing a polymeric resonator exhibiting a high thermooptic coefficient on a silicon substrate with a small coefficient of thermal expansion. For the range of from $20^{\circ}C$ to $30^{\circ}C$ near the room temperature, the fabricated sensor yielded a sensitivity of as high as 165 ${\pm}/^{\circ}C$ and a resolution of better than $0.1^{\circ}C$. And its performance was found to be hardly affected by the variation in the refractive index of the target analyte, which was applied to the surface of the sensor. It is hence expected that the sensor could be integrated with other refractormetric optical sensors, thereby compensating for the fatal error caused by the change in the ambient temperature.

A study on the characteristic comparision of systems which measure the temperature of coal powder in feader lines of boiler (급탄관 온도 측정시스템의 특성 비교분석에 관한 연구)

  • 오면택;이복규;이원빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.597-600
    • /
    • 1996
  • This study has compared the two types of systems which measure the temperature of coal powder in feeder lines of boiler and analyzed operating data. We used RTD(Resistance Temperature Detector) and optic sensors to measure the temperature. From the characteristic comparison of data, field test and system operation, we confirm that the latter is more efficient than the former.

  • PDF

Fault Analysis of Transformer using Tunable Infrared Gas Sensors (가변 파장형 적외선 센서를 이용한 변압기 결함 진단)

  • Gun-Ho Lee;Seung-Hwan Yi
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.55-61
    • /
    • 2023
  • The objective of this study is to determine the concentrations of mixed gases by establishing a diagnosis method of a transformer using tunable-wavelength optical infrared sensors. Absorption of infrared light by methane, acetylene, and ethylene gases injected is measured from the outputs of the infrared sensors. Regression analysis equations of the gas concentrations are acquired from their respective measured absorption. The obtained concentrations are as follows: -3-9 % errors above 600 ppm(methane), 3 % errors above 1200 ppm(acetylene), and 10 % errors above 500 ppm(ethylene). The concentration inference equations obtained using the individual gases are applicable when the absorption wavelength bands do not overlap. The results of the fault analysis of a transformer using the Duval triangle method and the tunable infrared gas sensors are as follows: temperature faults with -1-1% errors and energy faults with -7-7 % errors.

Effects of Temperature and Humidity on NDIR CO2 Gas Sensor (비분산 적외선 이산화탄소 가스센서 특성의 온·습도 영향)

  • Kim, JinHo;Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.179-185
    • /
    • 2017
  • This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humidifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient temperature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ${\pm}5%$ from 400 to 2,000 ppm.

Silicon Oil-Based 2-Channel Fiber-Optic Temperature Sensor Using a Subtraction Method (감법을 이용한 실리콘 오일 기반의 2채널 광섬유 온도 센서)

  • Lee, Dong Eun;Yoo, Wook Jae;Shin, Sang Hun;Kim, Mingeon;Song, Young Beom;Kim, Hye Jin;Jang, Kyoung Won;Tack, Gye Rae;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.344-348
    • /
    • 2016
  • We developed a 2-channel fiber-optic temperature sensor (FOTS) using a temperature sensing probe, a fiber-optic coupler, transmitting optical fiber, and an optical time domain reflectometer (OTDR). The temperature sensing probe is divided into a sensing probe and a reference probe for accurate thermometry. A sensing probe is composed of a silicon oil, a FC terminator, a brass pipe, and a singlemode optical fiber and the structure of a reference probe is identical with that of the sensing probe excluding a silicon oil. In this study, we measured the modified optical powers of the light signals reflected from the temperature sensing probe placed inside of the water with a thermal variation from 5 to $70^{\circ}C$. Although the optical power of the reference probe was constant regardless of the temperature change, the optical power of the sensing probe decreased linearly as the temperature increased. As experimental results, the FOTS using a subtraction method showed a small difference (i.e., hysteresis) in its response due to heating and cooling. The reversibility and reproducibility of the FOTS were also evaluated.

Impact of Electric Field on Propagation Velocity of Phase Boundary Between Nematic and Isotropic Phases of 5CB Liquid Crystal

  • Adeshina, Mohammad Awwal;Kumar, Mareddi Bharath;Kang, Daekyung;Choi, Bongjun;Park, Jonghoo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.341-344
    • /
    • 2019
  • Liquid crystal (LC) mesophase materials manifest a variety of phase transitions. The optical properties of LCs are highly dependent upon the phase and orientation of the optical axis with respect to the polarization of incoming light. Studying the LC phase transitions is significantly important for a wide range of scientific and industrial applications. In this study, we demonstrate the propagation velocity of the phase boundary between the nematic and isotropic phase of 4-Cyano-4-pentylbiphenyl (5CB) liquid crystal for different electric fields using a polarized optical microscope. The results demonstrate that the propagation velocity of the phase boundary exhibits a peak value for a specific voltage, attributed to the supercooling of the isotropic phase of the LC. The analysis of the propagation velocity for different electric fields also provides a simple optical platform to measure the thermal anisotropy and voltage dependent thermal properties of the homogeneously aligned LC.