• 제목/요약/키워드: Optical standard and testing

검색결과 27건 처리시간 0.018초

Estimation of liquid limit of cohesive soil using video-based vibration measurement

  • Matthew Sands;Evan Hayes;Soonkie Nam;Jinki Kim
    • Geomechanics and Engineering
    • /
    • 제33권2호
    • /
    • pp.175-182
    • /
    • 2023
  • In general, the design of structures and its construction processes are fundamentally dependent on their foundation and supporting ground. Thus, it is imperative to understand the behavior of the soil under certain stress and drainage conditions. As it is well known that certain characteristics and behaviors of soils with fines are highly dependent on water content, it is critical to accurately measure and identify the status of the soils in terms of water contents. Liquid limit is one of the important soil index properties to define such characteristics. However, liquid limit measurement can be affected by the proficiency of the operator. On the other hand, dynamic properties of soils are also necessary in many different applications and current testing methods often require special equipment in the laboratory, which is often expensive and sensitive to test conditions. In order to address these concerns and advance the state of the art, this study explores a novel method to determine the liquid limit of cohesive soil by employing video-based vibration analysis. In this research, the modal characteristics of cohesive soil columns are extracted from videos by utilizing phase-based motion estimation. By utilizing the proposed method that analyzes the optical flow in every pixel of the series of frames that effectively represents the motion of corresponding points of the soil specimen, the vibration characteristics of the entire soil specimen could be assessed in a non-contact and non-destructive manner. The experimental investigation results compared with the liquid limit determined by the standard method verify that the proposed method reliably and straightforwardly identifies the liquid limit of clay. It is envisioned that the proposed approach could be applied to measuring liquid limit of soil in practical field, entertaining its simple implementation that only requires a digital camera or even a smartphone without the need for special equipment that may be subject to the proficiency of the operator.

디지털 카메라 색 특성분석을 통한 sRGB 이미지 생성 (Making of sRGB image through digital camera colorimetric characterization)

  • 유종우;김홍석;박승옥;박철호;박진희
    • 한국광학회지
    • /
    • 제15권2호
    • /
    • pp.183-189
    • /
    • 2004
  • 고화질 디지털 카메라가 널리 보급되면서 디지털 카메라는 단순한 영상 기록 장치가 아닌 정보 저장 매체로써 다양한 분야에서 사용되고 있다. 그러나 디지털 카메라의 분광 감도가 표준 관측자의 색 일치 함수와 다르기 때문에 카메라로는 색이 정확하게 측정될 수 없다. 본 연구는 카메라 이미지를 피사체의 색 정보를 지니고 있는 sRGB 이미지로 변환하는 방법에 관한 것이다. 디지털 카메라의 출력 신호와 CIE 삼자극치간의 변환 행렬은 Macbeth ColorChecker 24색을 기준 색으로 하여 다중 회귀법을 사용하여 구하였다. 변환 행렬을 이용하여 카메라의 출력 신호로부터 피사체의 실제 색을 찾아내어 이상적인 sRGB 표준 모니터에 정확하게 나타낼 수 있는 RGB 데이터로 변환하였다. Kodak DC220 디지털 카메라로 생성된 Macbeth ColorChecker의 sRGB 이미지와 실제 색과의 평균 색차는 2.1 $\Delta$ $E_{ab}$ $^{*}$ 시험 색표로 사용된 IT8 Reference KIT(286색)의 sRGB 이미지와 실제 색과의 평균 색차는 4.6 $\Delta$ $E_{ab}$ $^{*}$ 로 계산되었다. ab/$^{*}$ 로 계산되었다.

안면부 여과식 방진 마스크와 안경 동시 착용 시 상호 영향 (The Effects of Interrelationship after Wearing between Respirators and Glasses Simultaneously)

  • 어원석;신창섭
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.47-53
    • /
    • 2018
  • This study compares the interrelation of fit factor(FF) and visual acuity test by the order of wearing preference between Particulate filtering face piece respirators(PFFR) and glasses for 54 participants. Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA) or Visual acuity. We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038 and compared the result of preference of wearing order between respirators and glasses. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis, peason correlation(P=0.05) Fit factor was increased when the respirator was worn before wearing the glasses(p=0.000) and decreased for visual acuity(p=0.000) The negative correlation was showed between OH and Overall fit factor(r=-0.409, p=0.002). Among 54 participants, 11 participants(20.3%) were worn respirator before wearing glasses and 1 participant(1.9%) was worn glasses before wearing respirator. The overall fit test showed the higher level was investigated for the group of participants wearing respirator before wearing glasses in 6 exercises. Also, overall fit factor were increased when participants wore glasses prior to respirator(16.6) to respirator prior to glasses(36.6). Visual acuity were increased when participants wore respirator prior to glasses(93.8) to glasses prior to respirator(106.0). Finally, comparison result of overall fit factor and visual acuity were glasses first choice from mask first choice. The results showed that higher overall fit factor was investigate when the participants wore the respirator prior to glassess at all. The results implied that it is important to maintain the overall fit factor and visual acuity according to the consideration of OH for glasses fitting when worker wore respirator and glasses at the same time.

LED 조명기구의 함정 적용과 효과분석 (Application and effect analysis of LED luminaires for naval vessels)

  • 조규룡;길경석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권9호
    • /
    • pp.812-817
    • /
    • 2016
  • 본 논문은 함정용 LED 조명기구의 전기적, 광학적 요구사항을 제시하고 실증으로 요구사항 만족여부를 확인하였으며, 2012년 함정에 최초 적용된 이후 현재까지 비용 효과를 분석하였다. 함정용 LED 조명기구의 요구사항을 도출하기 위하여 한국산업규격(KS), 국방규격(KDS) 및 미 해군규격(MIL)의 요구사항을 비교하여 함정용 LED 조명기구의 요구사항을 제시하였다. 형광등기구와 LED 조명기구의 전기적 특성과 광학적 특성을 실험으로 분석하여 요구사항 적용 타당성을 검증하였고, 제시된 함정용 LED 조명기구의 요구사항으로 A1함정에 주 조명등으로 설치되었다. LED 조명기구로 설치된 이후 형광등에 비해 소비전력은 약 40% 감소되었고, 광속은 10 ~ 15% 증가하였다. 또한, 2012년에서 2015년까지 함정 10척에서 약 4,900개의 형광등기구가 감소되는 효과가 있었고, 약 5.6억원의 절감효과를 확인하였다. 향후 지속적으로 함정에 LED 조명기구를 설치하고 있어 많은 절감효과가 기대된다.

유기조성물을 이용한 페이스트형 일반도재 시스템 (Development of Organic Paste Porcelain for Fixed Prostheses)

  • 한중석;이명현;김대현;정헌영
    • 구강회복응용과학지
    • /
    • 제20권2호
    • /
    • pp.109-120
    • /
    • 2004
  • 덴틴, 에나멜, 투명 일반도재를 페이스트화 하여 치아의 색상, 투명도 및 구조를 고려한 복합층구성물을 미리 제조하여 심미수복물을 용이하게 제작하는 공정을 개발하였다. 페이스트 상태에서 성형성과 유동특성이 확보되고, 소성 후 색도, 및 강도 등의 제특성들을 만족시킬 수 있는 결합제 시스템으로서 UV (creation universal liquid)를 선정하였고 조성 및 최적화가 이루어졌다. 페이스트는 24시간까지도 점성 및 작업성이 유지되었고, 이를 이용하여 복합층 구성물의 용이한 성형이 가능하였다. 소성수축률은 15.2%로 기존의 방법으로 제조한 시편에 비해 0.8% 낮았으나 유의차는 없었다. spectrophotometer에 의한 색도특성 관찰결과 덴틴재를 기존 제조방식으로 제조한 시편과 페이스트형 도재 시스템으로 제조한 시편에서 $L^*$, $a^*$, $b^*$가 각각 60~80, -1.5~+1.5, 5~20 사이의 값을 나타냄을 확인하였다. 측정값으로부터 구해진 제조방식에 따른 시편 간의 색차(${\Delta}E^*$)는 0.156으로 극히 근소한 차이를 나타냄을 확인하였다. 유기물 첨가에 따른 소성 후 잔류물 함량은 검출오차범위 내에 있었으며, 기존의 제조방식으로 제조한 소성체와 페이스트형 도재 시스템을 이용한 소성체의 강도는 각각 $70{\pm}4MPa$, $74{\pm}3MPa$으로 유의차가 없이 근사한 물성을 나타내었다. 페이스트형 도재를 이용한 도재축성법을 기존방법과 비교분석한 결과, 기계적 또는 광학적 특성의 변화없이 적용이 가능하였다.

선량 판독용 OSL 측정장치의 개발 (Development of OSL Dosimetry Reader)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.10-15
    • /
    • 2012
  • 개인 선량계로 활용될 수 있는 광자극발광(OSL: optically stimulated luminescence) 측정장치의 개발과 이를 위한 이론적 배경 및 개발된 장치의 성능에 대하여 기술하였다. OSL 측정장치는 자극광원과 시료로부터 자극 발광된 광신호 사이의 간섭효과를 최소화하기 위하여 다양한 광학적 필터 조합을 구성해야 하는데, 여기서는 자극광에는 GG420 필터를, 측정부에는 UG11과 BG39 필터로 $Al_2O_3:C$ OSL 물질에 최적화된 광학적 필터를 구성하였다. 자극광원으로 Luxeon V형 고휘도 Blue LED를 선택함으로서 충분한 광량을 확보하였다. 또한 장비 제어 및 측정을 위하여 PC와 OSL 장치 사이에 다양한 제어보드들이 이용되며, 전체 장치의 자동화 및 장치제어는 LabView 프로그램을 이용하여 개발하였다. 개발된 OSL 장치의 신뢰도 및 재현성 평가를 위해 대표적인 OSL 물질인 $Al_2O_3:C$를 이용하여 OSL 특성곡선을 측정하고 이를 기존 상용 OSL 측정장치와 비교하였다.

2차원 DIC 기법 적용을 위한 2D 이미지 보정 수치 해석 기법 (2D Image Numerical Correction Method for 2D Digital Image Correlation)

  • 김원섭;홍석무
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.391-397
    • /
    • 2017
  • 최근의 DIC (Digital Image Correlation) 기술은 인장 시험 중 동적 변형을 측정하는 데 사용되고 있다. 표준 인장 시험 방법은 진응력 - 진변형 곡선을 계산하기 위해 두 표점 거리 간 측정된 평균 변위를 사용한다. 따라서, 진응력 곡선은 균일 연신 구간, 즉 네킹 변형 시작점까지만 유효하다. 반면에, DIC를 사용한다면, 전체 측정 영역에서 국부 변형을 측정할 수 있기 때문에 변형률 및 변형률 속도의 유효한 범위가 인장 시편이 파단될 때까지 확장될 수 있다. 이러한 장점 때문에 연구 및 산업 분야에서 많은 광학 3D 측정 시스템이 도입되고 사용되었지만 기존의 3D 측정 시스템은 측정하기에 너무 비싸고 시간이 많이 소요된다. 또한 장비 크기로 인해 휴대가 불편한 단점이 존재한다. 본 논문에서는 기존의 스마트 폰을 이용한 2D DIC 측정 방법과 수치 해석 기법을 사용하여 2D 측정 영상 데이터의 오차를 개선한 2D 영상 보정 방법을 수행 하였다. 2D DIC 수정 제안 된 방법의 결과는 3D 측정 장비의 정확도에 비해 더 높은 정확도를 보였다. 결론적으로, 제안 된 2D DIC 및 보정 방법이 정확하고 신속한 측정 결과를 제공한다는 것이 입증되었다.