• Title/Summary/Keyword: Optical recording system

Search Result 132, Processing Time 0.025 seconds

An experimental Study on the Motion of a Floater Moored Near Port in Waves Generated by a Ship

  • Nguyen, Van Minh;Nguyen, Thi Thanh Diep;Yoon, Hyeon-Kyu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.05a
    • /
    • pp.98-100
    • /
    • 2019
  • In the past, there were several researchers investigating waves generated by a small boat. Wave generated by a ship can be divided into two distinct systems of waves, such as transverse and diverging waves. It is necessary to understand the behavior of a ship in waves generated by a small boat near port in the view point of ship safety. In this study, the motion of moored floater in waves generated by a small boat near port is investigated. The model test is performed in waves in a square tank in Changwon National University (CWNU). IMU and optical-based system which uses the technique of recording and capturing attitude with respect time are used for measuring 6DOF motion of the moored floater. In addition, tension gauges are used to measure the tension of mooring lines. The effect of waves generated by a small boat on motion of the moored floater near port is investigated through performing the model test in various wave directions of virtually but reasonably assumed wave scenarios.

  • PDF

Development of An Automated Scanning Laser Doppler Vibrometer for Measurements of In-Plane Structural Vibration (평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구)

  • Kil, Hyun-Gwon
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 1997
  • An automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane vibration fields over structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

1$\times$16 DMUX Using Holographic Volume Gratings (홀로그래픽 부피격자를 이용한 1$\times$16 DMUX)

  • Lee, Kwon-Yeon;An, Jun-Won;Kim, Nam;Lee, Hyun-Jae;Seo, Wan-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.5
    • /
    • pp.31-38
    • /
    • 2000
  • We propose a new photorefractive demultiplexer(DMUX) which can select the 16 channel signal in WDM optical communication system using the wavelength selectivity and the demultiplexing property through multiple recording of holographic volume grating in photorefractive Fe-LiNbO$_{3}$ crystal. For the multiple writing of the 16 channels having uniform diffraction efficiency, the rotation multiplexing technique and the exposure time schedule are used. Designed DMUX has the 16 channels with 0.5nm spacing between 670nm and 677.5nm and the bandwidth of 0.16nm. From the experimental results, the diffraction efficiency of each channel is 8.3 $\pm$0.62%, the optical loss from fresnel reflection and absorption on the crystal is 0.4cm-1, the 3㏈ bandwidth is 0.16 $\pm$0.005nm and the channel spacing is 0.46~0.5nm.

  • PDF

Method of Display and Processing of Binocular Stereoscopic Image for 3D Endoscopy (3차원 내시경술을 위한 양안 입체 영상처리 및 디스플레이 방법)

  • 송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.531-538
    • /
    • 1998
  • This paper represents the design of 3D endoscopic image processing system in order to Improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. The proposed 3D systems have four features of stereo endoscopic image processing The multiplexer give field seauential stereo for recording and for aligning cameras and viewing stereo with 3D monitor. Demultiplexing of the field sequential image which separates out the R and L images for dual TFT-LCD 3D monitor viewed with passive polarized glasses. separable processing of the left and right eye images, and design of TFT-LCD 3D monitor. The viewing angle, zone, and image quality of the Polarization-type Stereoscopic Display (SM500TFT-3D) system which we have developed using 15 Samsung TFT-1.CD with a screen resolution of 1024×768 pixels were measured and compared with those of Electric Shutter-type Stereoscopic Display system. The result of experiments shows that the Polarization-type Stereoscopic Display System using TFT-LCD has a wade viewing angle and zone which Is necessary fort multi-view and it has better image quality and stability of the optical performances than the Electric Shutter-type does.

  • PDF

A Study on Smart Accuracy Control System based on Augmented Reality and Portable Measurement Device for Shipbuilding (조선소 블록 정도관리를 위한 경량화 측정 장비 및 증강현실 기반의 스마트 정도관리 시스템 개발)

  • Nam, Byeong-Wook;Lee, Kyung-Ho;Lee, Won-Hyuk;Lee, Jae-Duck;Hwang, Ho-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.1
    • /
    • pp.65-73
    • /
    • 2019
  • In order to increase the production efficiency of the ship and shorten the production cycle, it is important to evaluate the accuracy of the ship components efficiently during the drying cycle. The accuracy control of the block is important for shortening the ship process, reducing the cost, and improving the accuracy of the ship. Some systems have been developed and used mainly in large shipyards, but in some cases, they are measured and managed using conventional measuring instruments such as tape measure and beam, optical instruments as optical equipment, In order to perform accuracy control, these tools and equipment as well as equipment for recording measurement data and paper drawings for measuring the measurement position are inevitably combined. The measured results are managed by the accuracy control system through manual input or recording device. In this case, the measurement result is influenced by the work environment and the skill level of the worker. Also, in the measurement result management side, there are a human error about the lack of the measurement result creation, the lack of the management sheet management, And costs are lost in terms of efficiency due to consumption. The purpose of this study is to improve the working environment in the existing accuracy management process by using the augmented reality technology to visualize the measurement information on the actual block and to obtain the measurement information And a smart management system based on augmented reality that can effectively manage the accuracy management data through interworking with measurement equipment. We confirmed the applicability of the proposed system to the accuracy control through the prototype implementation.

A study about the problems and their solutions in the production process of 3D character animation using optical motion capture technology (옵티컬 모션캡쳐 기술을 활용한 3D 캐릭터 애니메이션에서 제작과정상 문제점 및 해결방안에 관한 연구)

  • Lee, Man-Woo;Kim, Hyun-Jong;Kim, Soon-Gohn
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.831-835
    • /
    • 2006
  • Motion capture means the recording of movement of objects such as human beings, animals, creatures, machines, etc in a form applicable to computer. Since the motion capture system can be introduced to the fields where realistic movement of human beings and animals, which cannot be attained with an existing key frame method is required, large scale is necessary or economical burden exists, it has a merit and possibility of new expression. For these reasons, this method is increasingly used in the field of digital entertainment such as movie, TV, advertisement, documentary, music video, etc centering around the game. However, in spite of such an advantage, problems such as too much advance preparation work in digital image expressions using motion capture, marker attachment, compensation of motion data, motion retargeting and lack of professional human resources, etc. are becoming a prominent figure. Accordingly, this study intends to suggest the way of more effective production of motion capture digital image through finding the problems and their draft possible solutions in the production process based on the image production examples using motion capture.

  • PDF

INLINE NEAR INFRARED (NIR) SPECTROSCOPY FOR PROCESS CONTROL IN POLYMER EXTRUSION

  • Rohe, Thomas;Koelle, Sabine;Becker, Wolfgang;Eisenreich, Norbert;Eyerer, Peter
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1082-1082
    • /
    • 2001
  • Extrusion is one of the most important processes in polymer industry. The characterization of the polymer melt during processing will improve this process noticeably, One possibility of characterizing the actual processed polymer melt is the inline near infrared (NIR) spectroscopy, With this method several polymer properties can be observed during processing, e.g. composition, moisture ormechanical properties of the melt. For this purpose probes for transmission and reflection measurements have been developed, withstanding the high temperatures and pressures appearing during extrusion process (tested up to 300$^{\circ}C$ and 10 ㎫). For the transmission system an optical bypass was developed to eliminate disturbing spectral influences and hence increase the long term stability, which is the prerequisite for an industrial application. Measurements in transmission and reflection produced comparable results (or blending processes, where the prediction error was less than 1%. An optimum RMSEP of only 0.24% was found for preprocessed polymer blends measured in transmission on a laboratory extruder. A transflection measurement allowed for the first time the recording of relevant NIR-spectra in the screw area of an extruder. The application to a (PE+PP) blending process delivered promising results. This new measurement mode allows the observation of the ongoing processes within the screw area, which is of maximum Interest for reactive extrusion processes. Due to economic reasons the calibration transfer between different extrusion systems is also of high importance. Investigations on simulated and real-world spectra showed that a calibration transfer is possible. A new method alternatively to the well-known direct standardization procedures was developed, which is based on an automatic data pretreatment. This procedure delivers comparable results for the calibration transfer. Overall this paper presents concepts, components and algorithms for the inline near infrared (NIR) spectroscopy for polymer extrusion, which allows the use of it in a real industrial extrusion process.

  • PDF

Total-internal-reflection Holographic Photo-lithography by Using Incoherent Light (비가간섭광을 이용한 내부전반사 홀로그래픽 리소그라피)

  • Lee, Joon-Sub;Park, Woo-Jae;Lee, Ji-Whan;Song, Seok-Ho;Lee, Sung-Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.334-338
    • /
    • 2009
  • Recently, with increasing demand for flat-panel display product, methods for large area patterning are required. TIR (total internal reflection) holographic photo-lithography isstudied as one of the methods of large area lithography. In conventional TIR holography, light sources for hologram recording and image reconstruction are coherent beams such as laser beams. If the image is reconstructed with an incoherent light source such a UV lamp, the image noise from the coherence of light will be reduced and the UV lamp will be a better light source for large area exposure. We analyzed the effect of spectral bandwidth and angular bandwidth of the light source in image reconstruction and verified image blurring with experiments. For large area patterning which has micro-scale line width, it is expected that TIR holographic photo lithography by UV lamp will become a low-noise and low-priced technique.

Novel approach to assessing the primary stability of dental implants under functional cyclic loading in vitro: a biomechanical pilot study using synthetic bone

  • Jean-Pierre Fischer;Stefan Schleifenbaum;Felicitas Gelberg;Thomas Barth;Toni Wendler;Sabine Loffler
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.3
    • /
    • pp.189-204
    • /
    • 2024
  • Purpose: This pilot study was conducted to develop a novel test setup for the in vitro assessment of the primary stability of dental implants. This was achieved by characterising their long-term behaviour based on the continuous recording of micromotions resulting from dynamic and cyclic loading. Methods: Twenty screw implants, each 11 mm in length and either 3.8 mm (for premolars) or 4.3 mm (for molars) in diameter, were inserted into the posterior region of 5 synthetic mandibular models. Physiological masticatory loads were simulated by superimposing cyclic buccal-lingual movement of the mandible with a vertically applied masticatory force. Using an optical 3-dimensional (3D) measuring system, the micromotions of the dental crowns relative to the alveolar bone resulting from alternating off-centre loads were concurrently determined over 10,000 test cycles. Results: The buccal-lingual deflections of the dental crowns significantly increased from cycle 10 to cycle 10,000 (P<0.05). The deflections increased sharply during the first 500 cycles before approaching a plateau. Premolars exhibited greater maximum deflections than molars. The bone regions located mesially and distally adjacent to the loaded implants demonstrated deflections that occurred synchronously and in the same direction as the applied loads. The overall spatial movement of the implants over time followed an hourglass-shaped loosening pattern with a characteristic pivot point 5.5±1.1 mm from the apical end. Conclusions: In synthetic mandibular models, the cyclic reciprocal loading of dental implants with an average masticatory force produces significant loosening. The evasive movements observed in the alveolar bone suggest that its anatomy and yielding could significantly influence the force distribution and, consequently, the mechanical behaviour of dental implants. The 3D visualisation of the overall implant movement under functional cyclic loading complements known methods and can contribute to the development of implant designs and surgical techniques by providing a more profound understanding of dynamic bone-implant interactions.

Shallow Marine Seismic Refraction Data Acquisition and Interpretation Using digital Technique (디지털 技法을 이용한 淺海底 屈折法 彈性波 探査資料의 取得과 解析)

  • 이호영;김철민
    • 한국해양학회지
    • /
    • v.27 no.1
    • /
    • pp.19-34
    • /
    • 1992
  • Marine seismic refraction surveys have been carried out by Korea Institute of Geology, Mining and Materials(KIGAM) since 1984. The recording of refraction data was based on analog instrumentation. Therefore the resolution of refraction data was not good enough to distinguish many layers. The objective of the interpretation of seismic refraction data is the determination of intervals and critically refracted seismic wave propagation velocities through the layers beneath the sea floor. To determine intervals and velocities precisely, the resolution of refraction data should be enhanced. The intent of the study is to improve the quality of shallow marine refraction data by the digital technique using microcomputer- based acquisition and processing system. The system consists of an IBM AT microcomputer clone, an analog-digital(A/D) converter. A mass storage unit and a parallel processing board. The A/D converter has 12 bits of precision and 250 kHz of conversion rate. The magneto-optical disk drive is used for the mass storage of seismic refraction data. Shallow marine seismic refraction surveys have been carried out using the system at 6 locations off Ulsan and Pusan area. The refraction data were acquired by the radio sonobuoy. The refraction profiles have been produced by the laser printer with 300 dpi resolution after the basic computer processing. 5-9 layers were interpreted from digital refraction profiles, whereas 2-4 layers were interpreted from analog refraction profiles. the propagation velocities of sediments were interpreted as 1.6-2.1 km/sec. The propagation velocities of acoustic basement were interpreted as 2.4-2.7 km/sec off Ulsan area, 4.8 km/sec off Pusan area.

  • PDF