• 제목/요약/키워드: Optical pH sensor

검색결과 43건 처리시간 0.023초

광섬유 pH 센서 개발을 위한 분광학적 연구 (Spectroscopic study on the development of fiber-optic pH sensor)

  • 유욱재;허지연;조동현;장경원;서정기;이봉수;조영호;문주현;박병기
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.365-371
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic pH sensor which is composed of a light source, plastic optical fibers and a spectrometer. As an indicator, a phenol red is used, and a pH liquid solution is prepared by mixing of phenol red and various kinds of pH buffer solutions in these experiments. The emitting light from a light source is guided by plastic optical fibers to the pH liquid solution, and the optical characteristic of a light is changed in the pH liquid solution according to its color change. Therefore, we have measured the intensities and wavelength shifts of the modulated lights, which are changed due to the color variations of phenol red at different pH values, by using of a spectrometer for spectral analysis. Also, the relationships between the pH values of liquid solutions and the optical properties of modulated light according to the change of color of phenol red are obtained.

냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발 (Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant)

  • 유욱재;이봉수;박병기;조영호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1730-1734
    • /
    • 2010
  • 원전 2차계통수의 pH를 예측을 위해서는 샘플을 채취, 냉각시킨 후 pH를 측정하게 되는데 이 때 샘플의 온도는 pH를 변화시키는 중요한 요인이 된다. 본 연구에서는 할로겐화 은 광섬유를 이용하여 비접촉식 온도센서를 개발하였고, 열전쌍열을 이용하여 열원으로부터 방출되는 적외선을 측정하였다. 열원과 광섬유 끝단 사이의 거리 및 각도 변화에 따른 광섬유 온도센서의 출력신호를 분석하였으며, 광섬유 온도센서로 측정한 온도범위는 $25{\sim}60^{\circ}C$이다. 본 연구결과를 기초로 원전 2차계통수 pH 샘플의 온도를 측정하기 위해 할로겐화 은 광섬유를 이용한 비접촉식 온도센서의 개발이 가능할 것으로 기대된다.

광학적 pH 센서를 위한 지시염료가 고정된 필름의 광학적 특성 연구 (Study on Optical Characteristics of pH Indicators in the Immobilized Film for Fiber-Optic pH Sensor)

  • 김범규;박병기
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.414-419
    • /
    • 2017
  • The optical characteristics of cresol red, phenol red, and neutral red immobilized in the thin film were investigated with absorbance measurement in order to find a sensing part of a fiber-optic pH sensor. Sol-Gel method with tetramethyl orthosilicate as a precursor was used to immobilize the pH indicators in the thin film. The absorbance spectra were measured when pH indicators were immobilized in the film and were dissolved in the buffer solution. Experimental results showed that the absorbance spectra could be changed when the pH indicator is immobilized in the thin film. As compared with other pH indicators, the neutral red exhibited similar absorbance spectra regardless of physical conditions and was sensitive over whole pH range between 4 and 11. In addition, the absorbance ratio of base peak to acid peak tended to increase in proportion to the increase in pH. Experimental results indicate that the neutral red is a good pH indicator for fabrication of a sensing part of the fiber-optic pH sensor.

세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석 (Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions)

  • 장지운;황인숙;이종목;이선민;강소라;김영미;김나영
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

졸-겔 필름을 이용한 반사형 광섬유 pH 센서의 개발 (Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film)

  • 유욱재;서정기;장경원;문진수;한기택;박장연;이봉수;조승현;허지연;박병기
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.266-271
    • /
    • 2011
  • A reflection-type fiber-optic pH sensor, which is composed of a pH sol-gel film, plastic optical fibers, a mirror, a light source and a spectrometer, is developed in this study. As pH indicators, a bromthymol blue, a cresol red and a thymol blue are used, and they are immobilized in the sol-gel films. The emitted light from a light source is guided by a fiber-optic Y-coupler and plastic optical fibers to the pH sol-gel film in a pH sensing probe. The pH change in the sensing probe gives rise to a change in the color of the pH sol-gel film, and the optical characteristic of reflected light through the pH sol-gel film is also changed. Therefore, we have measured the spectra of reflected lights, which are changed according to the color variations of the pH sol-gel films with different pH values, by using of a spectrometer. Also, the relationships between the pH values and the intensities of reflected lights are obtained on the basis of the color variations of the pH sol-gel films.

$SiO_2$ 포켈 소자를 이용한 광전압센서 (Optical Voltage Sensor Using $SiO_2$ Pockels Cell)

  • 신건학;추진부;조홍근;김석구;김요희;김영수;박해수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.846-849
    • /
    • 1991
  • This paper reports the principle, system confiquration, test results of optical voltage sensor using quartz pockels cell. The Pockels effect of quartz material is used for designing optical voltage sensor. The quarts material has very high half-wave voltage, so, it can be applied to measure high voltage level. Experimental results show that the optical voltage sensor has excellent linear characteristics within the applied AC voltage of 1200V.

  • PDF

내시경용 광섬유 pH 측정 센서 개발을 위한 기초 연구 (Feasibility Study on the Development of Fiber-Optic pH Sensor for Endoscope)

  • 이봉수;홍주영;황영묵;조승현
    • 센서학회지
    • /
    • 제13권3호
    • /
    • pp.213-217
    • /
    • 2004
  • The general method to find a H. pylori in the stomach is the rapid urease test but it is only used to decide the infection with H. pylori. In this study, it is tried to develope fiber-optic pH sensor which can be used with gastroscop to quantify H. pylori. To measure the degree of infection with H. pylori, the color change of phenol red according to the degree of pH is measured by optical fibers with different light sources and the optimum distance from a sample to the end of sensor tip is decided by measuring the maximum reflectivity from a sample. Also the sensitivity study is carried out to decide the optimum light source which has sensitive change of reflectivity to the change of pH. It is expected that the fiber-optic pH sensor which measures the degree of infection with H. pylori exactly can be developed.

실리카 졸-겔막을 이용한 pH 광학센서 (A pH Optosensor Based on Fluoresence from Nile Blue Encapsulated within Silica Sol-Gel Film)

  • 이정민;이명;이상학;김영선;김창진;이부형
    • 센서학회지
    • /
    • 제13권3호
    • /
    • pp.169-174
    • /
    • 2004
  • A fiber optic pH sensor has been fabricated using nile blue entrapped in an ammonia catalyzed silica sol-gel film coated on glass substrate by dip-coating. The sensor was fixed on the end of an optical fiber. The sensor showed pH sensitivity when dipped into liquids at different pHs. Linear and reproducible responses were obtained in standard buffer solutions in the pH range $6.0{\sim}8.5$, which encompasses the clinically-relevant range. The effects of interferences on the determination of pH were also investigated. The sensors were successfully applied to the determination of pH in different commercial ionic drinks.

Study on pH Sensor using Methylene Blue Adsorption and A Long-Period Optical Fiber Grating Pair

  • Jeon Young-Hee;Kwon Jae-Joong;Lee Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.28-32
    • /
    • 2006
  • We propose a new pH-sensing scheme using a methylene blue adsorption on an optical fiber cladding surface. Interactions between the silica and hydroxyl ions of a base solution induce the surface of the silica negatively charged. The charged surface attracts the positively charged chromophores of methylene blue. As the pH of the solution is reduced, the electrostatic attraction will also be reduced. This electrostatic attraction can change the transmitted light intensity of the cladding mode, since the boundary condition changes. We also carried out a simulation to verify the effect from external refractive index change around a long-period fiber grating. Our results confirm that the wavelength shift by external refractive index change is negligible compared to the transmitted light intensity variation of the cladding mode. By using a long-period grating pair, we can detect the cladding mode transmittance variations. Experimentally, we showed the possibility of pH sensing in the $1.5{\mu}m$ infrared region.

광섬유 국소화 표면 플라즈몬 공명 센서를 위한 광섬유 표면상의 금 나노 입자 특성 분석 (Characterization of gold nanoparticles on optical fiber for localized surface plasmon resonance sensor)

  • 이훈;이승기
    • 센서학회지
    • /
    • 제18권3호
    • /
    • pp.226-233
    • /
    • 2009
  • In this study, the optical properties of localized surface plasmon resonance sensor using optical fiber was analyzed as the variation of a size and surface density of gold nano particles on the etched optical fiber surface. It is shown that a size and surface density of gold nano particles on optical fiber surface are controlled by $Na_3$ citrate quantity and pH of gold colloid solution. To measure the sensitivity, peak wavelength of absorbance spectrum was detected as the reflective index of the solution. The sensor sensitivity is linearly dependent on the size and surface densities of gold nano particles from the results of optical experiments.