• 제목/요약/키워드: Optical instruments

검색결과 189건 처리시간 0.027초

Thermo-optic Characteristics of Micro-structured Optical Fiber Infiltrated with Mixture Liquids

  • Wang, Ran;Wang, Yuye;Miao, Yinping;Lu, Ying;Luan, Nannan;Hao, Congjing;Duan, Liangcheng;Yuan, Cai;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제17권3호
    • /
    • pp.231-236
    • /
    • 2013
  • We present both theoretically and experimentally the thermo-optic characteristics of micro-structured optical fiber (MOF) filled with mixed liquid. The performance of MOF depends on the efficient interaction between the fundamental mode of the transmitted light wave and the tunable thermo-optic materials in the cladding. The numerical simulation indicates that the confinement loss of MOF presents higher temperature dependence with higher air-filling ratios $d/{\Lambda}$, longer incident wavelength and fewer air holes in the cladding. For the 4cm liquid-filled grapefruit MOF, we demonstrate from experiments that different proportions of solutions lead to tunable temperature sensitive ranges. The insertion loss and the extinction ratio are 3~4 dB and approximate 20 dB, respectively. The proposed liquid-filling MOF will be developed as thermo-optic sensor, attenuator or optical switch with the advantages of simple structure, compact configuration and easy fabrication.

Telephotolens design with refractove/diffractive hybrid lens

  • Hong, Young-Ghi;Kim, Sun-Il;Yeo, Wan-Gu;Lee, Chul-Koo
    • Journal of the Optical Society of Korea
    • /
    • 제1권2호
    • /
    • pp.74-80
    • /
    • 1997
  • 300mm F/4.0 telephotolens with diffractive hybrid lens was designed, and its optical performance was tested and compared with a traditional lens system. DOE(Diffractive Optical Element) reconstructs wavefronts using wave phenomena of light to focus the incident light onto the focal point and has negative Abbe number while a traditional lens uses geometrical phenomena of light and has positive Abbe number. Therefore, a diffractive hybrid lens containing both refractive and diffractive elements can remarkably correct chromatic aberration and spherical aberration of an optical system. We investigated and analyzed the optical properties of a diffractive hybrid lens for the visible spectrum, and we used a difractive hybrid lens to design and evaluate a 300mm F/4.0 telephotolens without the special LD(Low Dispersive) glass lens which is costly and difficult to manufacture. Most traditional telephotolenses use the special LD glass for chromatic aberration correcton. Optical performance tests such as resolution and characteristics of aberration of both lens systems using a diffractive hybrid lens and traditional lens were performed.

TELEMETRY TIMING ANALYSIS FOR IMAGE RECONSTRUCTION OF KOMPSAT SPACECRAFT

  • Lee, Jin-Ho;Chang, Young-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • 제17권1호
    • /
    • pp.117-122
    • /
    • 2000
  • The KOMPSAT(Korea Multi-Purpose SATellite) has two optical imaging instruments called EOC(Electro-Optical Camera) and OSMI (Ocean Scanning Multispectral Imager). The image data of these instruments are transmitted to ground station and restored correctly after post-processing with the telemetry data transfeered from KOMPSAT spacecraft. The major timing information of the KOMPSAT is OBT (On-Board Time) which is formatted by the on-board computer of the spacecraft, based on 1Hz sync. pulse coming from the GPS receiver involved. The OBT is transmitted to ground station with the house-keeping telemetry data of the spacecraft while it is distributed to the instruments via 1553B data bus for synchronization during imaging and formatting. The timing information contained in the spacecraft telemetry data would have direct relation to the image data of the instruments, which should be well explained to get a more accurate image. This paper addresses the timing analysis of the KOMPSAT spacecraft and instruments, including the gyro data timing analysis for the correct restoration of the EOC and OSMI image data at ground station.

  • PDF

CURRENT STATUS OF THE INSTRUMENTS, INSTRUMENTATION AND OPEN USE OF OKAYAMA ASTROPHYSICAL OBSERVATORY

  • YOSHIDA MICHITOSHI
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.117-120
    • /
    • 2005
  • Current instrumentation activities and the open user status of Okayama Astrophysical Observatory (OAO) are reviewed. There are two telescopes in operation and one telescope under reforming at OAO. The 188cm telescope is provided for open use for more than 200 nights in a year. The typical over-subscription rate of observation proposals for the 188cm telescope is ${\~}$ 1.5 - 2. The 50cm telescope is dedicated to $\gamma$-ray burst optical follow-up observation and is operated in collaboration with Tokyo Institute of Technology. The 91cm telescope will become a new very wide field near-infrared camera in two years. The high-dispersion echelle spectrograph (HIDES) is the current primary instrument for the open use of the 188cm telescope. Two new instruments, an infrared multi-purpose camera (ISLE) and an optical low-dispersion spectrograph (KOOLS), are now under development. They will be open as common use instruments in 2006.

스카이라디오미터 모델에 따른 에어러솔의 광학적 특성 비교 (Comparison of Aerosol Optical Properties from Different Models of Skyradiometer)

  • 최용주;김영성;손병주
    • 대기
    • /
    • 제21권3호
    • /
    • pp.311-317
    • /
    • 2011
  • Aerosol optical properties from the radiation measurements by SKYNET PREDE skyradiometers, POM-01 and POM-02 were compared during the inter-calibration campaign at Seoul in February 2009. The monochromatic solar flux at the top of the atmosphere ($F_0$) gave a relative standard deviation (RSD) of 9-10% for both instruments. This comparatively high value of RSD was probably because $F_0$ was determined at short time intervals, in the morning and afternoon, using the measurements made in the polluted environment of Seoul. Although POM-02 was more effective in tracking the solar radiation, aerosol optical depths (AODs) from the two instruments were very similar after the cloud screening procedure. The squared correlation coefficients ($R^2$) of single scattering albedo (SSA) and real and imaginary refractive indices between the two instruments was around 0.5 but increased to 0.7-0.8 when only using AOD greater than 0.4. Nevertheless, mean values of the Angstrom exponent, SSA, and the imaginary refractive index of POM-02 were higher than those of POM-01.

Approach of Self-mixing Interferometry Based on Particle Swarm Optimization for Absolute Distance Estimation

  • Li, Li;Li, Xingfei;Kou, Ke;Wu, Tengfei
    • Journal of the Optical Society of Korea
    • /
    • 제19권1호
    • /
    • pp.95-101
    • /
    • 2015
  • To accurately extract absolute distance information from a self-mixing interferometry (SMI) signal, in this paper we propose an approach based on a particle swarm optimization (PSO) algorithm instead of frequency estimation for absolute distance. The algorithm is utilized to search for the global minimum of the fitness function that is established from the self-mixing signal to find out the actual distance. A resolution superior to $25{\mu}m$ in the range from 3 to 20 cm is obtained by experimental measurement, and the results demonstrate the superiority of the proposed approach in comparison with interpolated FFT. The influence of different external feedback strength parameters and different inertia weights in the algorithm is discussed as well.

Optimization of Reflectron for Kinetic and Mechanistic Studies with Multiplexed Multiple Tandem (MSn) Time-of-flight Mass Spectrometry

  • Bae, Yong-Jin;Yoon, So-Hee;Moon, Jeong-Hee;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권1호
    • /
    • pp.92-99
    • /
    • 2010
  • Photoexcitation of a precursor ion inside a cell floated at high voltage installed in a tandem time-of-flight (TOF) mass spectrometer provides triple tandem mass spectrometric information and allows kinetic and mechanistic studies. In this work, the factors affecting, or downgrading, the performance of the technique were identified. Ion-optical and computational analyses showed that an optimum instrument could be designed by utilizing a reflectron with linear-plus-quadratic potential inside. Theoretical predictions were confirmed by tests with instruments built with different ion-optical layout. With optimized instruments, masses of intermediate ions in the consecutive dissociation of a precursor ion could be determined with the maximum error of $\pm5$ Da. We also observed excellent agreement in dynamical parameters (critical energy and entropy) for the dissociation of a model peptide ion determined by instruments with different ion-optical layout operated under optimum conditions. This suggests that these parameters can be determined reliably by the kinetic method developed previously when properly designed and operated tandem TOF instruments are used.