• Title/Summary/Keyword: Optical impression

Search Result 27, Processing Time 0.02 seconds

Double-Layer 3D Rear Projection Display System using Scattering Polarizer Film (후면투사 방식의 이중스크린 3D 프로젝션 디스플레이)

  • Kim, Tae-Ho;Seo, Jong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.421-425
    • /
    • 2007
  • A new 3D rear projection display system using double-layer polarization-selective screen systems, one stacked in front of the other, has been developed. The front and rear screens are made of scattering polarizer films, and they either diffuse-scatter or transmit the incident light depending on the polarization state of the light. The near and for images are projected onto the front and rear screens, respectively, using light waves with mutually orthogonal polarization states. The new display system produces clear high-resolution images, which are visible over a wide range of viewing angle. It was found that the impression of depth is pronounced and eyestrain is only comparable to that by 2D display systems.

Histological Analysis Effect of 'Sexiang Shuhuo Jing' for after Skeletal Muscle in Rats (골격근 손상에 대한 '사향서활정(麝香舒活精)' 치료 효과에 대한 조직형태학적 관찰)

  • Kim, Jin-Hang;Song, Je-Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.6
    • /
    • pp.1543-1547
    • /
    • 2006
  • The aim of this experiment was to observe and analysis clinical effect of the 'Sexiang shuhuo Jing' on histological change for 14days after skeletal muscle injury in rats. The gastrocnemius muscles of rats were damaged by electromechanical and serial cryosections of the damaged muscle were prepared at 1, 5, 10, 14 days after injury. Muscle sample of the both control and 'Sexiang Shuhuo Jing' treated group were prepared for histological analysis by optical microscope and electron microscopy. 'Sexiang Shuhuo Jing' treatment group's skeletal muscle recovery was much more faster than control group. After 5 day's 'Sexiang Shuhuo Jing' treatment group's basically recovery normal structure of muscle fiber. After 14 day's control group's damaged muscle were basically recovery structure of muscle fiber but still has some factor of pathological impression but in Sexiang Shuhuo Jing treatment group's can't be found that.

Analysis of Satisfaction Surveys in Accordance with the Characteristics of the Components of Trick Art Experience Exhibition Space During -Around Seoul Trick Art Exhibition of Three Cases- (트릭아트 체험전시공간의 구성요소별 특성에 따른 만족도조사 분석 - 서울지역의 트릭아트전시관 3개 사례를 중심으로 -)

  • Lee, Dong-Hee;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.139-145
    • /
    • 2014
  • As life is changing, modern people are interested in culture life more than the past and as a result Art Exhibition increases. Nowadays many methods of exhibit are introduced, especially Direct experience. Trick Art Experience exhibition introduced Direct experirence to a work of art for interests and used props, objets, images, and sounds for maximizing experience element. Trick Art Experience exhibition added humor as imitating famous painting and gave a deep impression through the optical illusion technique which make flat structure look three-dimensional structure. Recently, demands for Experience exhibition which are like Trick Art increase. This study figure out pros and cons through a comparison analysis of direction and component about Trick Art Experience exhibition and find a check list about making an audience active about experience. From now on, we have an object about showing design data including customer satisfaction measurement to make various expressions of direction and component about Experience Art through a case analysis. We have firsthand visited case spaces to experience the spaces and prepared a check list for the relevant types of expressions. Referring to the exhibit work classification system, components that correspond to Trick Art Experience exhibition were grouped according to constituting items. Among the types of expressions, the levels of satisfaction with Experience exhibition and Participating exhibit were found to be high and the level of satisfaction with Heart Moving exhibit was found to be low through surveys. Among the components, the levels of satisfaction with stereograms and formative effect elements were found to be high and those of spatial changes and media effects were found to be low through surveys. Therefore, the expressions should be reinforced and the components should be improved.

Assessment of inlay ceramic restorations manufactured using the hot-pressing method (열 가압 방식을 사용하여 제작된 인레이 세라믹 수복물의 적합도 평가)

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Park, Dong-In;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the marginal and internal fit of lithium disilicate ceramic inlay produced by heat pressing that inlay pattern made by subtractive manufacturing and additive manufacturing method. Methods: A mandibular lower first molar that mesial occlusal cavity (MO cavity) die was prepared. After fabricating an epoxy resin model using a silicone impression material, epoxy resin die was scanned with a dental model scanner to design an MO cavity inlay. The designed STL pile was used to fabricate wax patterns and resin patterns, and then lithium disilicate ceramic inlays were fabricated using hot-press method. For the measurement of the marginal and internal gap of the lithium disilicate, silicone replica method was applied, and gap was measured through an optical microscope (x 80). Data were tested for significant differences using the Mann-Whitney Utest. Results: The marginal fit was 103.56±9.92㎛ in the MIL-IN group and 81.57±9.33㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). The internal fit was 120.99±17.52㎛ in the MIL-IN group and 99.18±6.65㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). Conclusion: It is clinically more appropriate to apply the additive manufacturing than subtractive manufacturing method in producing lithium disilicate inlay using CAD/CAM system.

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Development of Hair Accessory Designs Using Royal Hair Ornaments (왕실 머리장식을 응용한 헤어 액세서리 디자인 개발)

  • Jinyoung Ryu;Jiyeon Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.83-90
    • /
    • 2023
  • The recent trend in younger generations of wearing traditional costumes or incorporating fusion hanbok into daily wear necessitates the development of modern hair accessories to complement hanbok. The purpose of this study is to develop practical and modern hair accessory designs inspired by royal women's hair ornaments that complement hanbok, and therefore expand the scope of fashion content development utilizing hanbok culture as well as meeting the demand for various experiences of traditional culture. This research studied the literature on traditional hairstyles and accessories of Queen Yeong and constructed models of these accessories for the purpose of empirical research. The production process first required creating a basic foundation of nylon mesh reflecting the silhouette of a traditional hairstyle, and then grafting a digital textile printed fabric using majestic and extravagant royal relics on top, thus employing the trompe l'oeil technique to ultimately give the impression of wearing traditional jewelry. As a result, a total of six hair accessory designs were completed, produced with hairbands, hair pins, and hair ties. In addition, the accessories are designed to be easily worn regardless of the wearer's hair style, and the stiff yet flexible nylon mesh effectively expresses the shape of a voluminous hairstyle and creates an optical illusion, blending into the hair. These research results present a unique aesthetic and cultural experience to the greater public seeking both daily entertainment and value from rarity.

An Anatomical Study of the Posterior Tympanum (한국인 중이강후벽에 관한 형태해부학적 고찰)

  • 양오규;윤강묵;심상열;김영명
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.2-19
    • /
    • 1982
  • The sinus tympani is subject to great variability in the size, shape and posterior extent. A heavy compact bony zone, especially in the posterior portion and the narrow space between the facial nerve and posterior semicircular canal are the limitation of surgical approach. The facial recess should be opened, creating a wide connection between the mesotympanum and mastoid in the Intact canal wall tympanoplasty with mastoidectomy. The surgically created limits of the facial recess are the facial nerve medially, the chorda tympani laterally and the bone adjacent to the incus superiorly. Using adult Korean's thirty-five temporal bones, the authors measured the osteologic reslationship in the posterior tympanum, especially sinus tympani and facial recess. The result was as followed. 1. The average distance from the anterior end of the pyramidal eminence. 1) to the edge of the sinus tympani directly posterior was 2.54(1.05-5.40)mm. 2) to the maximum posterior extent was 3.22(1.25-7.45)mm. 3) to the maximum cephaled extent was 0.67 (0.40-1.75)mm. 2. The boundary of the sinus tympani was 82.9% from the lower margin oval window to the upper margin round window niche. 3. The deepest part of the sinus tympani was 62.9% in the mid portion, between the ponticulus and subiculum. 4. The oblique dimension from the fossa incudis above to the hypotympanum below was 8.13(7.90-9.55)mm. 5. The transverse dimensions midway between the oval window above and round window below was 3.00(2.85-3.45)mm. 6. The transverse dimension at the level of the fossa incudis was 1.81(1.40-2.15)mm. 7. The facial nerve dehiscence was 14.3%. 8. Anterior-posterior diameter of the footplate was 2.98(2.85-3.05) mm. 9. The average distance from the footplate. 1) to the cochleariform process was 1.42(1.35-1.55) mm. 2) to the round window niche was 1.85(1.45-2.10) mm.

  • PDF