• Title/Summary/Keyword: Optical fiber measurement

Search Result 465, Processing Time 0.022 seconds

Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance (보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서)

  • Kim, S.G.;Shin, S.H.;Jeon, D.;Hong, S.H.;Sim, H.I.;Jang, K.W.;Yoo, W.J.;Lee, B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

Preparation of Regenerated Cellulose Fiber via Carbonation. I. Carbonation and Dissolution in an Aqueous NaOH Solution

  • Oh, Sang Youn;Yoo, Dong Il;Shin, Younsook;Lee, Wha Seop;Jo, Seong Mu
    • Fibers and Polymers
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Cellulose carbonate was prepared by the reaction of cellulose pulp and $CO_2$ with treatment reagents, such as aqueous $Zncl_2$ (20-40 wt%) solution, acetone or ethyl acetate, at -5-$0^{\circ}C$ and 30-40 bar ($CO_2$) for 2 hr. Among the treatment reagents, ethyl acetate was the most effective. Cellulose carbonate was dissolved in 10% sodium hydroxide solution containing zinc oxide up to 3 wt% at -5-$0^{\circ}C$. Intrinsic viscosities of raw cellulose and cellulose carbonate were measured with an Ubbelohde viscometer using 0.5 M cupriethylenediamine hydroxide (cuen) as a solvent at $20^{\circ}C$ according to ASTM D1795 method. The molecular weight of cellulose was rarely changed by carbonation. Solubility of cellulose carbonate was tested by optical microscopic observation, UV absorbance and viscosity measurement. Phase diagram of cellulose carbonate was obtained by combining the results of solubility evaluation. Maximum concentration of cellulose carbonate for soluble zone was increased with increasing zinc oxide content. Cellulose carbonate solution in good soluble zone was transparent and showed the lowest absorbance and the highest viscosity. The cellulose carbonate and its solution were stable in refrigerator (-$5^{\circ}C$ and atmospheric pressure).

Development of On-line Technology for Measuring Stock Consistency Using Optical Sensor (Part 2) - Effect of stock properties on the relationship between the turbidity and transmittance of stocks and consistency - (광학센서를 이용한 지료의 농도 평가 기술 개발(제2보) - 펄프의 특성 변화가 농도와 탁도 및 투과율의 상관관계에 미치는 영향 -)

  • Lee Ji-Young;Youn Hye-Jung;Lee Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.1 s.113
    • /
    • pp.16-20
    • /
    • 2006
  • The effect of the freeness of pulp slurries on turbidity and transmittance of papermaking stocks was investigated using beaten bleached hardwood pulp stocks with freeness ranging from 651 mL to 403 mL CSF. Also the influence of fiber length on the turbidity and transmittance was examined with fractionated pulp stocks. Increases in stock consistency increased the turbidity. Transmittance of stock samples decreased, however, with the increase of stock consistency. Second order equations and exponential equations have been obtained as regression equations for the turbidity and transmittance of these stock samples, respectively.

Integrity of Optical Fiber Sensor for Measurement of Ground Thermal Conductivity (지중 열전도도 측정을 위한 광섬유 센서의 건전성)

  • Yoon, Seok;Choi, Jung-Chan;Lee, Seung-Rae;Lee, Michael-MyungSub
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.157-160
    • /
    • 2011
  • 본 연구에서는 광섬유 센서 기반 스마트 모니터링 시스템이 지중 열전도도 측정에도 효율적으로 적용될 수 있는지를 분석하였다. 이를 위해 광섬유 온도센서를 이용하여 지반의 열전도도를 측정할 수 있는 열응답 시험기가 개발되었다. 개발된 열응답 시험기는 기존의 RTD(Resistance Temperature Detector) 온도 센서 외에 광섬유 센서의 한 종류인 FBG(Fiber Bragg Grating) 센서도 실시간적으로 측정할 수 있는 시스템으로 구성되어 있다. 개발된 장비의 적용성 검증을 위하여 주문진 표준사를 이용하여 모형토조 내에 일정한 간극비에 맞추어 시료가 조성되었으며 지중열교환기는 U자형 파이프가 사용되었다. 20시간동안 열응답 시험을 통하여 광섬유 센서와 RTD 센서를 동시에 이용하여 온도값을 측정하여 표준사의 열전도도 값을 산출하였다. 그 결과 모형실험을 통한 열전도도 값은 탐침법을 통해 얻어진 열전도도 값과 선형 열원 모델(line source model) 해석해와 거의 유사하게 나타났으며 광섬유 센서와 RTD 센서와의 온도차는 0.1~0.3$^{\circ}$로써 유사한 값을 나타내었다. 따라서 본 연구에서 개발된 광섬유 기반 열응답 시험기는 지반의 열전도도를 측정하는데 효과적으로 사용될 수 있음을 알 수 있었으며 향후 지열시스템 가동에 따른 지중열 교환기의 손상도 평가 및 경보시스템 개발을 위해 지중열교환기의 거동을 실시간으로 모니터링 하는데 있어서도 효과적으로 사용될 수 있을 것으로 생각된다.

  • PDF

Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I) (다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I))

  • Ahn, Jae-Hyun;Kim, Yong-Mo;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Study on the temperature and optical wavelength sensing composites as smart materials (온도 및 광파장을 감지하는 스마트 복합재료에 관한 연구)

  • ;Delbert E. Day;James O. Stoffer
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.3
    • /
    • pp.439-448
    • /
    • 1996
  • The possibility of application or the transparent BK10 glass fiber/PMMA composites as a temperature-or wavelength-sensors was studied. Measurement of diameter and refractive index for glass fibers to be reinforced to PMMA as a function of drawing speed and temperature was done and the appropriate coating methods and solvent for coupling agent was researched. $T_{max%}$ value at which the maximum transmission for the composites occurs could be controlled to be in $31~50^{\circ}C$ by the processing factors such as fiber diameter, fiber vol%, molecular wt. of PMMA. Furthermore, with different wavelength other than 589.3 nm, the $T_{max%}$ value could be controlled to be in $35~55^{\circ}C$. For the sensibility of wavelength for the composites, there was not a wavelength ($\lamda_{max%}$) showing maximum transmission.

  • PDF

Phase-shifting diffraction grating interferometer for testing concave mirrors (오목 거울 측정용 위상천이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.392-398
    • /
    • 2003
  • We present a novel concept of a phase-shifting diffraction-grating interferometer, which is intended for the optical testing of concave mirrors with high precision. The interferometer is configured with a single reflective diffraction grating, which performs multiple functions of beam splitting, beam recombination, and phase shifting. The reference and test wave fronts are generated by means of reflective diffraction at the focal plane of a microscope objective with large numerical aperture, which allows testing fast mirrors with low f-numbers. The fiber-optic confocal design is adopted for the microscope objective to focus a converging beam on the diffractive grating, which greatly reduces the alignment error between the focusing optics and the diffraction grating. Translating the grating provides phase shifting, which allows measurement of the figure errors of the test mirror to nanometer accuracy.

LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor (국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.666-671
    • /
    • 2016
  • This paper introduces a device providing close local lighting to the affected part, where the operation-purpose astral lamp alone cannot shed light directly, in an operation room of hospitals or clinics, which helps clinical doctors perform safe treatment of the affected part deep inside a human body. This medical assisting lighting is a device necessary to prevent fatal operation failures, which can occur with minute operation processes, such as tumor removal or angiorrhaphy. The components, such as the light source and power supply were designed to be low power consuming and small in size, have a narrow angle lens was used to increase the light spreading effect and focused illumination. The end-caps of the light transmission device using an optical cable and the lighting device were designed in the waterproof type to enable disinfection of these devices after use for the next patients. According to the measurement of the light source properties made after development of the retractor lighting device, the illumination intensity was 490 lux, the brightness was $11,550cd/m^2$, general color rendering index was 78, color temperature was 11,000K, and the intensity distribution was even, which were confirmed to be adequate for medical assisting local lighting.

Multiple FBG Sensor System Using Code Division Multiple Access (코드분할 다중화 방식을 이용한 다중 광섬유 브래그 격자 센서 시스템)

  • Ryu, Hyung-Don;Lee, Ho-Joon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.27-33
    • /
    • 2001
  • The performance of the ordinary Fiber Bragg Grating(FBG) sensor strain measurement system, which uses Fabry-Perot filter for scanning wavelength, has limitation for application because of hysteresis characteristics of PZT element in the filter, slow scan rate of the filter and the high cost of system. We proposed and experimented a multiple FBG sensor system using light emitting diode(LED) as a light source and adapting Code Division Multiplexing(CDM) method to separating out individual sensor signal. Output signals for a applied static and dynamic strain and crosstalk levels between sensor signals were measured. The price of the system is very loss and the response speed is very fast. Crosstalk levels between sensor signals below - 30 dB were demonstrated.

  • PDF

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.