• Title/Summary/Keyword: Optical fiber humidity sensor

Search Result 7, Processing Time 0.022 seconds

Polyimide Film-coated Side-polished Optical Fiber Humidity Sensor (폴리이미드가 코팅된 측면 연마 광섬유를 이용한 습도 센서)

  • Kwang Taek Kim;Jae Chang Yang
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.51-54
    • /
    • 2023
  • We investigated a humidity sensor based on a polyimide-coated side-polished optical fiber. The polyimide film absorbed moisture, causing the resonant wavelength of the sensor to shift to a longer wavelength owing to the changes in the optical properties of the film. The experimental results showed that the resonant wavelength of the device shifted by 17-18 nm when relative humidity changed from 30% to 90%.

Highly Sensitive Optical-fiber Humidity Sensor Based on Nafion-PVA Sol-gel

  • Ning, Wang;Yuhao, Li;Xiaolei, Yin;Wenting, Liu;Shiqi, Liu; Xuwei, Zhao; Yanxi, Zhong;Liang, Xu
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 2023
  • A highly sensitive optical-fiber humidity sensor is demonstrated in this paper. By using Nafion-PVA sol-gel and single-mode optical fibers, the Fabry-Perot humidity sensor is easily fabricated. In the humidity range of 29%-72%, humidity-response experiments are carried out with a cycle of rising and falling humidity to investigate humidity-response characteristics. The experimental results show 2.25 nm/%RH sensitivity and a 0.9997 linear correlation coefficient, with good consistency. The changes in optical-path difference (OPD) and free spectral range (FSR) with humidity are also discussed. The humidity sensitivities of a typical sensor are 80.3 nm/%RH (OPD) and 0.03 nm/%RH (FSR). Furthermore, many humidity sensors with different Nafion-PVA sol-gel concentration and initial cavity length are experimentally investigated for humidity response. The results show that the sensitivity increases with higher Nafion ratio of the Nafion-PVA sol-gel. The influence of changing cavity length on sensitivity is not obvious. These results are helpful to research on optical-fiber humidity sensors with good performance, easy fabrication, and low cost.

Humidity and Temperature Response Characteristics of Optical Fiber Dislocation Fusion Sensor Coated with Graphene Quantum Dots

  • Dailin Li;Xiaodan Yu;Ning Wang;Wenting Liu;Shiqi Liu;Liang Xu;Dong Fang;Huapeng Yu
    • Current Optics and Photonics
    • /
    • v.7 no.5
    • /
    • pp.504-510
    • /
    • 2023
  • An optical fiber dislocation fusion humidity sensor coated with graphene quantum dots is investigated. A Mach-Zehnder interferometer is fabricated with three dislocated single-mode fibers with graphene quantum dots coating humidity-sensitive materials. Humidity response experiments showed a good linear response and high sensitivity with easy fabrication and low-cost materials. From 22% to 98% RH, the humidity response sensitivity of the sensor is 0.24 dB/% RH, with 0.9825 linearity. To investigate the cross-response of humidity and temperature, temperature response experiments are conducted. From 30 ℃ to 70 ℃, the results showed 0.02 dB/℃ sensitivity and 0.9824 linearity. The humidity response experimental curve is compared with the temperature experimental curve. The big difference between humidity sensitivity and temperature sensitivity is very helpful to solve the cross-response of humidity and temperature. The influence of temperature fluctuations in humidity measurements is not obvious.

Fiber-optic humidity sensor system for the monitoring and detection of coolant leakage in nuclear power plants

  • Kim, Hye Jin;Shin, Hyun Young;Pyeon, Cheol Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1689-1696
    • /
    • 2020
  • In this study, we developed a fiber-optic humidity sensor (FOHS) system for the monitoring and detection of coolant leakage in nuclear power plants. The FOHS system includes an FOHS, a spectrometer, a halogen white-light source, and a Y-coupler. The FOHS is composed of a humidity-sensing material, a metal tube, a multi-mode plastic optical fiber, and a subminiature version A (SMA) fiber-optic connector. The humidity-sensing material is synthesized from a mixture of polyvinylidene fluoride (PVDF) in dimethyl sulfoxide (DMSO) and hydroxyethyl cellulose (HEC) in distilled water. We measured the optical intensity of the light signals reflected from the FOHS placed inside the humidity chamber with relative humidity (RH) variation from 40 to 95%. We found that the optical intensity of the sensing probe increased linearly with the RH. The reversibility and reproducibility of the FOHS were also evaluated.

Theoretical Analysis and Optimization of Extrinsic Fabry-Perot Interferometer Optical-fiber Humidity-sensor Structures

  • Yin, Xiao Lei;Wang, Ning;Yu, Xiao Dan;Li, Yu Hao;Zhang, Bo;Li, Dai Lin
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.652-659
    • /
    • 2021
  • The theoretical analysis and optimization of extrinsic Fabry-Perot interferometer (EFPI) opticalfiber humidity sensors are deeply investigated. For a typical dual-cavity structure composed of an optical fiber and a humidity-sensitive membrane (HSM), the changes in refractive index (RI) and initial length are discussed for polymer materials and porous oxide materials when relative humidity (RH) increases. The typical interference spectrum is simulated at different RH using MATLAB. The spectral change caused by changing HSM RI and initial length are simulated simutineously, showing different influences on humidity response. To deeply investigate the influence on RH sensitivity, the typical response sensitivity curves for different HSM lengths and air-cavity lengths are simulated. The results show that the HSM is the vital factor. Short HSM length can improve the sensitivity, but for HSM RI and length the influences on sensitivity are opposite, because of the opposite spectral-shift trend. Deep discussion and an optimization method are provided to solve this problem. According to analysis, an opaque HSM is helpful to improve sensitivity. Furthermore, if using an opaque HSM, a short air cavity and long HSM length can improve the sensor's sensitivity These results provide deep understanding and some ideas for designing and optimizing highly sensitive EFPI fiber humidity sensors.

Humidity Sensor Using Polyimide Film Coated Fiber Bragg Grating (폴리이미드가 코팅된 광섬유 브래그 격자를 이용한 습도센서)

  • Jae Chang Yang;Gun Pyo Kim;Kwang Taek Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.594-597
    • /
    • 2023
  • We have proposed and demonstrated a fiber optic RH (relative humidity) sensor based on fiber Bragg grating covered with a polyimide film. As the polyimide film absolves the moisture in the air, its volume expands. As a result, the grating period of the FBG (fiber Bragg grating) covered with a polyimide film becomes wide and the Bragg wavelength is shifted. The sensor is implemented by fixing a 30 ㎛ thickness polyimide film on the surface of an optical fiber grating using an adhesive, and the characteristics of the device according to humidity are analyzed. The fabricated FBG RH sensor showed a high sensitivity of 0.0186 nm/RH% and a wide measurement range from 30% to 90%. The influence of environmental temperature on the characteristics of the RH sensor was also measured and analyzed. The feasibility of commercialization is presented.

Gelatin Film Coated Fiber-Optic Directional Coupler-Based Humidity Sensors (젤라틴 코팅을 이용한 광섬유형 방향성 결합기 기반 습도 센서)

  • Son, Gyeongho;Kim, Minchul;Yu, Kyoungsik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.865-871
    • /
    • 2017
  • In this paper, a gelatin layer was formed on the surface of the twisted fiber-optic couplers fabricated by hydrofluoric acid, which can be used to measure relative humidity. The proposed method of sensors has advantage of low cost compared with the sensors based on the conventional electronic devices and takes beneficial characteristics of optical fibers and light. The fiber-optic sensors presented in this study show a measurement from about 40% to 85% relative humidity, and the experimental results agree well with the calculated results. Based on the design presented in this paper, the structure will enable promising applications in the detecting humidity and various hazardous gases.