• Title/Summary/Keyword: Optical diagnosis

Search Result 222, Processing Time 0.029 seconds

Development of a real-time Analysis System of Microchip Fluorescence Images based on Server-Client (서버 클라이언트 기반의 실시간 마이크로칩 형광 이미지 분석 시스템 개발)

  • Cho, Migyung;Shim, Jaesool
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1239-1244
    • /
    • 2013
  • In the field of clinical medicine and research, the analysis of such as protein and DNA at the molecular level and even at the cell level are necessary for disease diagnosis and treatment. In many cases, a real time image of samples is needed for the accurate analysis and manipulation of samples since experimental samples are degenerated with time. In this research, a three-dimensional fluorescence microscope device was developed for taking images of protein and DNA inside a single cell and the server-client based image analysis system was made for an integrated management of the real-time images taken from the microscope device. The system consists of a fluorescent measurement device, the associated software and a client program on smartphone. The developed system allows doctors or experimental managers to receive and look at the real-time experimental images taken from the samples of patients anywhere in the emergency, to analyze results and to instantly diagnose the disease and to transfer the results to the patients. As a result, the system is able to be utilized in the implementation of ubiquitous health as well.

An Algorithm Study to Detect Mass Flow Controller Error in Plasma Deposition Equipment Using Artificial Immune System (인공면역체계를 이용한 플라즈마 증착 장비의 유량조절기 오류 검출 실험 연구)

  • You, Young Min;Jeong, Ji Yoon;Ch, Na Hyeon;Park, So Eun;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.161-166
    • /
    • 2021
  • Errors in the semiconductor process are generated by a change in the state of the equipment, and errors usually arise when the state of the equipment changes or when parts that make up the equipment have flaws. In this investigation, we anticipated that aging of the mass flow controller in the plasma enhanced chemical vapor deposition SiO2 thin film deposition method caused a minute flow rate shift. In seven cases, fourier transformation infrared film quality analysis of the deposited thin film was used to characterize normal and pathological processes. The plasma condition was monitored using optical emission spectrometry data as the flow rate changed during the procedure. Preprocessing was used to apply the collected OES data to the artificial immune system algorithm, which was then used to process diagnosis. Through comparisons between datasets, the learning algorithm compared classification accuracy and improved the method. It has been confirmed that data characterized as a normal process and abnormal processes with differing flow rates may be discriminated by themselves using the artificial immune system data mining method.

Diagnosis of the Transitional Disk Structure of AA Ori by Modeling of Multi-Wavelength Observations

  • Kim, Kyoung Hee;Kim, Hyosun;Lee, Chang Won;Lyo, Aran
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.42.2-42.2
    • /
    • 2020
  • We report on multi-wavelength observations of AA Ori, a Young Stellar Object in Orion-A star-forming region. AA Ori is known to have a pre-transitional disk based on infrared observations including Spitzer/IRS data. We construct its broadband spectral energy distribution (SED) by not only taking data in the optical and IR region but also including Herschel/PACS, JCMT/SCUBA, and SMA observational data. We use the Monte Carlo radiative transfer code (RADMC-3D) to reconstruct the SED with a viscous accretion disk model initialized by a radially continuous disk and finally having an inner and outer dusty disk separated by a dust-depleted radial gap. By comparing the model SEDs with different configurations of disk parameters, we discuss the limits to find a single solution of model parameters to fit the data. We suggest that some models with a modified inner disk surface density gradient and some degree of dust depletion in the inner disk can explain the AA Ori's SED, from which we infer that the inner disk of AA Ori has evolved. We present that model configurations of a pre-transitional disk with a large gap extended to 60-80 AU in a settled dusty disk of a few hundred AU size with a high inclination angle (~60°) also create model SEDs close to the observed one. To distinguish whether the disk has a just-opened narrow gap or a large gap, with an altered surface density of the inner disk extended to 10 AU, we suggest a further investigation of AA Ori with high angular resolution observations.

  • PDF

Design of Fluorescence Multi-cancer Diagnostic Sensor Platform based on Microfluidics (미세 유체 기반의 형광 다중 암 진단 센서 플랫폼 설계)

  • Lee, B.K.;Khaliq, A.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.55-61
    • /
    • 2022
  • There is a major interest in diagnostic technology for multiple cancers worldwide. In order to reduce the difficulty of cancer diagnosis, a liquid biopsy technology based on a microfluidic device using trace amounts of biofluids such as blood is being studied. And optical biosensing, which measures the concentration of analytes through fluorescence imaging using biofluids, requires various strategies to improve sensitivity, and specialists and equipment are needed to carry out these strategies. This leads to an increase in diagnostic and production costs, and it is necessary to develop a technology to solve this problem. In this paper, we design and propose a fluorescent multi-cancer diagnostic sensing platform structure that implements passive self-separation technology and molecular recognition activation functions by fluid mixing, only with the geometry and microfluidic phenomena of microchannels based on self-driven flow by capillary force. In order to check the parameters affecting the performance of the plasma separation part of the designed sensor, the hydrodynamic diameter of the channel and the viscosity of the fluid were set as variables to confirm the formation of plasma separation flow through simulation. And finally, we propose an optimal sensor platform structure.

Utility of intraoral scanner imaging for dental plaque detection

  • Chihiro Yoshiga;Kazuya Doi;Hiroshi Oue;Reiko Kobatake;Maiko Kawagoe;Hanako Umehara;Kazuhiro Tsuga
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.43-48
    • /
    • 2024
  • Purpose: Oral hygiene, maintained through plaque control, helps prevent periodontal disease and dental caries. This study was conducted to examine the accuracy of plaque detection with an intraoral scanner(IOS) compared to images captured with an optical camera. Materials and Methods: To examine the effect of color tone, artificial tooth resin samples were stained red, blue, and green, after which images were acquired with a digital single-lens reflex (DSLR) camera and an IOS device. Stained surface ratios were then determined and compared. Additionally, the deviation rate of the IOS relative to the DSLR camera was computed for each color. In the clinical study, following plaque staining with red disclosing solution, the staining was captured by the DSLR and IOS devices, and the stained area on each image was measured. Results: The stained surface ratios did not differ significantly between DSLR and IOS images for any color group. Additionally, the deviation rate did not vary significantly across colors. In the clinical test, the stained plaque appeared slightly lighter in color, and the delineation of the stained areas less distinct, on the IOS compared to the DSLR images. However, the stained surface ratio was significantly higher in the IOS than in the DSLR group. Conclusion: When employing IOS with dental plaque staining, the impact of color was minimal, suggesting that the traditional red stain remains suitable for plaque detection. IOS images appeared relatively blurred and enlarged relative to the true state of the teeth, due to inferior sharpness compared to camera images.

Methods for Coating the Killed Whole Cell Antigens of Salmonella typhi in Enzyme-linked Immunosorbent Assay (효소면역측정법을 위한 장티푸스 균체항원의 부착방법)

  • Kim, Youn-Won;Hwang, Eung-Soo;Kook, Yoon-Hoh;Choi, Kang-Won;Kim, Ik-Sang;Cha, Chang-Yong;Lee, Seung-Hoon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.20 no.1
    • /
    • pp.91-102
    • /
    • 1985
  • The advantages of enzyme-linked immunosorbent assay(ELISA) are its senstivity and simplicity in detecting IgG, IgM and IgA antibody. To apply ELISA to diagnosis of typhoid fever, antigen such as lipopolysaccharide of Salmonella typhi or killed whole cell must be coated on solid phase. It is easy to coat lipopolysaccharide on ELISA plate but troublesome to purify it. As it is easy to obtain the killed whole cells, the development of the appropriate method by which those antigens of S. typhi are optimally coated on solid phase is needed. To establish the appropriate method, carbonate buffer, methanol or poly-L-lysine was applied as binding substance on polystyrene or polyvinylchloride plate as solid phase when the killed whole cell antigens of S. typhi varided as follows: $10^6$, $10^7$, $10^8$ and $10^9\;cell/ml$. The criteria of the optimal method were determined as follows: 1. The optical density of positive sera is above 1.0(0.6 in IgM) at 1:10 serum dilution and is 0.3(0.2 in IgM) higher than that of negative sera: 2. The O.D. of sera is flat or lowering according to serum dilution: 3. It must be that the O.D. of negative sera is lower than 0.2 at the point of serum dilution where the O.D. of positive sera is higher than 1.0(0.5 in IgM). The results obtained were summarized as follows: 1. The methods which fitted the above criteria were to use poly-L-lysine as binding substance, polyvinylchloride plate as solid phase and $10^7\;cell/ml$ as antigen concentration of S. typhi(poly-L-lysine/polyvinylchloride/$10^7$) and poly-L-lysine/polyvinylchloride/$10^8$ in detecting IgG antibody, methanol/polystyrene/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgM and carbonate buffer/polystyrene/$10^8$, carbonate buffer/polystyrene/$10^9$, methanol/polystyrene/$10^8$, methanol/polyvinylchloride/$10^8$, methanol/polyvinylchloride/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgA. 2. The coaling method using poly-L-lysine, polyvinylchloride plate and $10^8\;cell/ml$ was best to assay IgG, IgM and IgA antibody all in one. By this method, to assay the each immunoglobulin calss with an appropriate fixed serum dilution, 1:320 dilution was best.

  • PDF

Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance (보행장애 진단을 위한 무릎관절 각도 측정용 광섬유 각도센서)

  • Kim, S.G.;Shin, S.H.;Jeon, D.;Hong, S.H.;Sim, H.I.;Jang, K.W.;Yoo, W.J.;Lee, B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1009-1013
    • /
    • 2013
  • In this study, we developed a fiber-optic goniometer for the continuous measurement of knee joint angle which provides important medical information on Alzheimer's disease. The fiber-optic goniometer is composed of a light-emitting diode (LED), a plastic optical fiber (POF), and a voltage output photodiode (PD). As a sensing part of the fiber-optic goniometer, a unclad fiber with regular intervals of 1 mm was fabricated to improve efficiency of bending loss according to the angle variation of knee joint. The emitting light with a center wavelength of 470 nm from a LED is guided by a POF to the PD, the transmitted light is then attenuated by the bending loss inside the bent POF. The intensity variation of the light transmitted from the POF gives rise to a change in output voltage in the fiber-optic goniometer. Therefore, we measured the real-time output voltage of the proposed fiber-optic goniometer using the unclad fiber according to the knee joint angle. Through the repeated experiments, the fiber-optic goniometer shows that it has a reversibility and a wide measurable angle range.

Development and Evaluation of an Automated Stainer for Mycobacterium Tuberculosis (결핵균 자동염색기의 개발 및 평가)

  • Kim, S. C.;Kang, S. I.;Kim, S. C.;Hwang, J. H.;Kim, S. Y.;Kim, Y.;Song, S. D.;Cho, S. N.;Kim, D. W.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.235-241
    • /
    • 2002
  • The detection of tubercle bacilli (TB) from sputum smear is one of the fast and inexpensive methods for diagnosis of tuberculosis. For this method. sputum smears are usually flexed by heating and stained by acid-fast staining method, and then examined under an optical microscope. Two Procedures are commonly used fur TB staining. One is hot staining and the other is cold staining method. The Ziehl-Neelsen method which is a hot staining method is widely used in Korea because its stained color is more vivid However, the conventional automated stainer has to fix the sputum smear on a slide manually and the stain is not so vivid because it has not heating function. In an effort to save labor and minimize variations in manual staining Procedure. we developed an automated stainer with heating function. The entire staining process is fully automated. from fixation to final washing and drying. With the automated methods, five slides can be flexed and stained in 21 minutes at consistent high quality We compared the concordance rate between the two methods for 91 sputum samples to validate the stain quality of the developed automated stainer. As the results, the concordant rate between the two methods was 95% and there was no significant difference (p>0.05)

Evaluation of Photochemical Reflectance Index (PRI) Response to Soybean Drought stress under Climate Change Conditions (기후변화 조건에서 콩 한발스트레스에 대한 광화학 반사 지수 반응 평가)

  • Sang, Wan-Gyu;Kim, Jun-Hwan;Shin, Pyeong;Baek, Jae-Kyeong;Lee, Yun-Ho;Cho, Jung-Il;Seo, Myung-Chul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.4
    • /
    • pp.261-268
    • /
    • 2019
  • Climate change and drought stress are having profound impacts on crop growth and development by altering crop physiological processes including photosynthetic activity. But finding a rapid, efficient, and non-destructive method for estimating environmental stress responses in the leaf and canopy is still a difficult issue for remote sensing research. We compared the relationships between photochemical reflectance index(PRI) and various optical and experimental indices on soybean drought stress under climate change conditions. Canopy photosynthesis trait, biomass change, chlorophyll fluorescence(Fv/Fm), stomatal conductance showed significant correlations with midday PRI value across the drought stress period under various climate conditions. In high temperature treatment, PRI were more sensitive to enhanced drought stress, demonstrating the negative effect of the high temperature on the drought stress. But high CO2 concentration alleviated the midday depression of both photosynthesis and PRI. Although air temperature and CO2 concentration could affect PRI interpretation and assessment of canopy radiation use efficiency(RUE), PRI was significantly correlated with canopy RUE both under climate change and drought stress conditions, indicating the applicability of PRI for tracking the drought stress responses in soybean. However, it is necessary to develop an integrated model for stress diagnosis using PRI at canopy level by minimizing the influence of physical and physiological factors on PRI and incorporating the effects of other vegetation indices.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF