• 제목/요약/키워드: Optical coherence

검색결과 342건 처리시간 0.023초

Measurement of Spatial Coherence Function of Laser Beam by using a Sagnac Interferometer

  • Lee, Chang-Hyouck;Kang, Yoon-Shik;Sung, Yu-Gene;Noh, Jae-Woo
    • Journal of the Optical Society of Korea
    • /
    • 제11권2호
    • /
    • pp.71-75
    • /
    • 2007
  • The spatial coherence function of a laser beam was measured by using a Sagnac interferometer and self referencing technique. For a laser beam passing through a narrow slit, the absolute value of the measured spatial coherence function becomes more symmetric as the slit size is reduced. For diverging beams, the spatial coherence function shows fast oscillations in its real and imaginary parts. We explain this by using a Gaussian Schell-model. One can use this measurement method to study and characterize the property of the light field coming out of a small sample.

표면 추적 알고리즘을 적용한 공통경로 FD-OCT의 성능개선 (Enhancement of Common-path Fourier-domain Optical Coherence Tomography using Active Surface Tracking Algorithm)

  • 김민호;김거식;송철규
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.639-642
    • /
    • 2012
  • Optical coherence tomography(OCT) can provide real-time and non-invasive subsurface imaging with ultra-high resolution of micrometer scale. However, conventional OCT systems generally have a limited imaging depth range within a depth of only 1-2 mm. To overcome the limitation, we have proposed an active surface tracking algorithm used in common-path Fourier-domain OCT system in order to extend the imaging depth range. The surface tracking algorithm based on the threshold and Savitzky-Golay filter of A-scan data was applied to real-time tracking. The algorithm has controlled a moving stage according to the sample's surface variance in real time. An OCT image obtained by the algorithm clearly show an extended imaging depth range. Consequently, the proposed algorithm demonstrated the potential for improving the conventional OCT systems with limitary depth range.

광원의 비선형 파장스위핑이 보정된 SS-OCT (Swept Source-Optical Coherence Tomography Using New Recalibration Method for Nonlinear Sweeping Laser)

  • 엄진섭
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.68-74
    • /
    • 2012
  • In this paper, Frequency Domain Mode Locked(FDML) wavelength swept laser with 55.027 kHz sweeping speed and 125 nm sweeping range has realized, and also a new method for recalibrating a nonlinear frequency sweeping of a swept laser has proposed. The Swept Source-Optical Coherence Tomography system using the proposed method has performed. For a mirror surface, the system showed the very clean 2-dimensional image and the advanced image speed of 7 frames per sec compared to the previous recalibration method.

루프 미러로 구성된 기준팔을 가지는 파장 스위핑 OCT 구현 (Realization of Swept Source Optical Coherence Tomography with Loop Mirror Reference Arm)

  • 김훈섭;남궁명우;이정렬;엄진섭
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.121-123
    • /
    • 2007
  • As a reflector of reference arm in OCT systems, a coated fiber reflector has mostly used. Instead, this paper has realized the swaept source optical coherence tomography system using a loop mirror within a reference arm. Through the experiments for a tilted thin glass plate, we found that the loop mirror is better than the coated fiber typed mirror for obtaining the clear image.

  • PDF

A case of Candida albicans-induced fungal keratitis in a Chihuahua dog - with a focus on optical coherence tomographic features

  • Heejong Cho;Manbok Jeong;Sukjong Yoo
    • Journal of Veterinary Science
    • /
    • 제24권2호
    • /
    • pp.30.1-30.6
    • /
    • 2023
  • A 4-year-old Chihuahua dog was referred for bilateral corneal ulcers. Slightly raised white fluorescein-positive plaque-like corneal lesions in both eyes appeared as intense hyperreflective areas with posterior shadowing on optical coherence tomography (OCT). Based on corneal cytology and culture, Candida albicans-induced fungal keratitis was diagnosed. Despite treatment, on OCT, endothelial plaques, increased stromal infiltration thickness, vertical shapes of the ulcer edge, and necrotic stromal space were judged to be aggravation of the disease, and surgery was performed. Conjunctival grafting surgery with topical 1% voriconazole effectively resolved fungal keratitis. OCT can provide detailed and objective information related to the disease prognosis.

Broadband Wavelength-swept Raman Laser for Fourier-domain Mode Locked Swept-source OCT

  • Lee, Hyung-Seok;Jung, Eun-Joo;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.316-320
    • /
    • 2009
  • A novel broadband wavelength-swept Raman laser was used to implement Fourier-domain mode locked (FDML) swept-source optical coherence tomography (SS-OCT). Instead of a conventional semiconductor optical amplifier, this study used broadband optical fiber Raman amplification, over 50 nm centered around 1545 nm, using a multi-wavelength optical pumping scheme, which was implemented with the four laser diodes at the center wavelengths of 1425, 1435, 1455 and 1465 nm, respectively, and the maximum operating power of 150 mW each. The operating swept frequency of the laser was determined to 16.7 kHz from the FDML condition of 12 km optical fiber in the ring cavity. The OCT images were obtained using the novel broadband wavelengthswept Raman laser source.

주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원 및 신호처리계의 구현 (Implementation of the Wavelength-Swept-Source and Signal Processing for the Frequency Domain Optical Coherence Tomography)

  • 이응제;김용평
    • 한국광학회지
    • /
    • 제18권5호
    • /
    • pp.309-316
    • /
    • 2007
  • 주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원과 주파수 보정(calibration)을 위한 신호처리계를 구현하였다. 제작된 레이저의 평균출력을 부스터(booster) 반도체 광 증폭기를 이용하여 14 mW까지 증폭시키고, 레이저 스펙트럼의 편이(shift)를 보상하였다. 패브리-페롯 에탈론(Fabry-Perot etalon)과 디지털 신호처리(digital signal processing)로 신호처리계를 제작함으로서 파장가변광원의 속도가변에 따른 비트주파수(beat frequency)의 넓어짐을 보정하였다. 제작된 광 간섭 단층촬영 시스템은 종방향 주사속도 154.4 kHz, 측정깊이 0.95 mm, 종방향 분해능 $12{\pm}0.37{\mu}m$의 특성을 가진다.

Counterfeit Detection Using Characterization of Safety Feature on Banknote with Full-field Optical Coherence Tomography

  • Choi, Woo-June;Min, Gi-Hyeon;Lee, Byeong-Ha;Eom, Jong-Hyun;Kim, Ju-Wan
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.316-320
    • /
    • 2010
  • We report an application of full-field optical coherence tomography (FF-OCT) for identifying counterfeit bank notes. The depth-resolved imaging capability of FF-OCT was used for tomographic identification of superficially-identical objects. By retrieving the internal structures of the security feature (cash hologram) of an original banknote, we could demonstrate the feasibility of FF-OCT to identify counterfeit money. The FF-OCT images showed that the hologram consisted of micron scale multi-coated layers including an air gap. Therefore, it is expected that FF-OCT has potential as a new non-invasive tool to discern imitation of currency, and it would find applications in a wide field of counterfeit sciences.

광간섭 단층 촬영 장치와 광음향 현미경의 결합을 통한 동시 이미지 획득 연구 (Simultaneous Imaging Using Combined Optical Coherence Tomography (OCT) and Photoacoustic Microscopy (PAM))

  • 김세희;이창호;한승훈;강현욱;오정환;김지현;김철홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.91-96
    • /
    • 2013
  • In this study, we developed an integrated optical coherence tomography - photoacoustic microscopy (OCT-PAM) system to simultaneously provide optical absorption and scattering information. Two different laser sources, such as a pulsed laser for PAM and a superluminescent diode for OCT, were employed to implement the integrated OCT-PAM system. The performance of the OCT-PAM system was measured by imaging carbon fibers. We then imaged black and white hairs to demonstrate the simultaneous OCT-PAM imaging capabilities. As a result, OCT can produce 3-D images of both black and white hairs, whereas PAM is only able to image the black hair due to strong optical absorption of black hair.

치석 진단용 소형 프로브 기반 광간섭단층촬영 시스템 (A Handheld Probe Based Optical Coherence Tomography System for Diagnosis of Dental Calculus)

  • 이창호;우채경;정웅규;강현욱;오정환;김지현
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.217-222
    • /
    • 2012
  • Optical coherence tomography(OCT) is a noninvasive optical imaging tool for biomedical applications. OCT can provide depth resolved two/three dimensional morphological images on biological samples. In this paper, we integrated an OCT system that was composed of an SLED(Superluminescent Light Emitting Diode, ${\lambda}_0$=1305 nm bandwith= 141 nm), a reference arm adopting a rapid scanning optical delay line(RSOD) to get high speed imaging, and a sample arm that used a micro electro mechanical systems(MEMS) scanning mirror. The sample arm contained a compact probe for imaging dental structures. The performance of the system was evaluated by imaging in-vivo human teeth with dental calculus, and the results indicated distinct appearance of dental calculus from enamel, gum or decayed teeth. The developed probe and system could successfully confirm the presence of dental calculus with a very high spatial resolution($6{\mu}m$).