• Title/Summary/Keyword: Optical coherence

Search Result 341, Processing Time 0.025 seconds

Compensations of Polarization Mode Dispersion and Thermal Drift in Optical Coherence Tomography with PZT Optical Delay Lines (광간섭 단층촬영(OCT)용 PZT 광경로 지연기에서의 편광모드 분산 및 열요동 보상)

  • Kim, Young-Kwan;Park, Sung-Jin;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.547-552
    • /
    • 2005
  • We have fabricated and characterized optical delay lines for optical coherence tomography, which is composed of cylindrical PZT(piezoelectric transducer) and single mode optical fiber. The polarization mode dispersion from the optical delay lines was compensated by the polarization controllers. By applying the duplex optical delay line, we minimized the thermal drift due to optical delay lines and obtained the scan range of 2 times that of a single optical delay line. The OCT system showed resolution of $18.6\pm0.5{\mu}m$, scanning range of 1.68mm, and scanning speed of 360.4mm/s.

Video Rate Image Signal Processing for Optical Coherence Tomography (광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구)

  • 나지훈;이병하;이창수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

Scientific and Engineering Applications of Full-field Swept-source Optical Coherence Tomography

  • Mehta, Dalip Singh;Anna, Tulsi;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.341-348
    • /
    • 2009
  • We report the development of full-field swept-source optical coherence tomography (SS-OCT) in the wavelength range of 815-870 nm using a unique combination of super-luminescent diode (SLD) as broad-band light source and acousto-optic tunable filter (AOTF) as a frequency-scanning device. Some new applications of full-field SS-OCT in forensic sciences and engineering materials have been demonstrated. Results of simultaneous topography and tomography of latent fingerprints, silicon microelectronic circuits and composite materials are presented. The main advantages of the present system are completely non-mechanical scanning, wide-field, compact and low-cost.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.

Measurement of Spatial Coherence Function of laser beam by using a Sagnac Interferometer (샤냑간섭계를 이용한 레이져빔의 Spatial Coherence Function 측정)

  • Lee, Chang-Hyouck;Kang, Yoon-Shik;Sung, Yu-Gene;Noh, Jae-Woo
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.111-112
    • /
    • 2007
  • The spatial coherence function of laser beam was measured by using a Sagnac interferometer and self referencing technique. For laser beam passing through a narrow slit, absolute value of measured spatial coherence function becomes more symmetric as the slit size is reduced. For diverging beams, the spatial coherence function shows fast oscillations in its real and imaginary parts. We explain this by using a Gaussian Schell-model. One can use this measurement method to study and characterize the property of light field coming out of small sample.

  • PDF

Modern Coherence Theory of Light (빛의 간섭성 이론)

  • 김기식;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.36-49
    • /
    • 1991
  • The coherence properties of electromagnetic fields are reviewed, based on both the classical and quantum theories. The elementary concepts, employed frequently in the discussion of interference phenomena, are summarized. The well-known interference phenomena are described in terms of second-order coherences. The coherence theory in space-frequency domain is introduced and the coherent mode representation is presented. The generation and propagation of coherence of light are analysed and it is shown that the coherence of light is developed as light propagates. The quantum theory goes parallel with the classical theory, via the optical equivalence theorem. There are, however, certain nonclassical characteristics of light, which may not be easily understood in classical therms. These nonclassical phenomena are believed to originate from the particle aspects of light. The quantum effect on the interfernce phenomena is analysed and finally the outlook of the future research is briefly mentioned.

  • PDF

Variation of Global Coherence on Propagation in Coherent Mode Representation

  • Kim, Ki-Sik;Park, Dae-Yoon
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.162-168
    • /
    • 2006
  • The variation of global coherence on propagation plane by plane is examined in the framework of coherent mode representation. It is explained through concrete examples that the global coherence may in general be enhanced, may be reduced, or may not change. When the mode functions form a complete set and the corresponding eigenvalues are in nitely degenerate, there necessarily develops a certain amount of global coherence on propagation, which is the essence of van Cittert-Zernike theorem. The propagation generates a certain pattern of the eigenvalue spectrum from the initial flat one and this is shown to be related to the non-unitarity of the propagation kernel.

Preliminary Experiment for High-resolution Measurement of Tissue Mechanical Properties Using Dynamic Optical Coherence Elastography (동적 광단층 탄성영상법을 이용한 조직의 고해상도 기계적 성질 측정을 위한 예비 실험)

  • Kwon, Daa Young;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.99-103
    • /
    • 2018
  • Optical coherence elastography (OCE) is based on optical coherence tomography (OCT), which is a noninvasive, high-resolution, cross-sectional imaging technique. In this paper, we have developed dynamic optical coherence elastography to measure elasticity, a mechanical property of tissue, by phase difference. A piezoelectric actuator was used for sinusoidal mechanical loading of samples. Before applying this method to biomaterial, we assessed the feasibility of OCE with samples of sponge, eraser, and sharp lead. Cross-sectional and phase-difference images of the sample were obtained under sinusoidal loading. The strain rate was calculated from the phase-difference information. To obtain the envelope of the phase-difference oscillations along the horizontal direction, Hilbert transformation was performed at each depth. The elevation of the envelope was represented by color mapping, and we could measure the relative elasticity within the sample by comparing the elevations. Finally, there was an advantage when we calculated the shear rate using self-interference in the sample arm, instead of the interference between sample and reference arms.

Evaluation of Skin Texture and Wrinkle Using Optical Coherence Tomography (Pilot Study) (피부결 및 주름 평가에 있어 광학단층영상술(Optical Coherence Tomography, OCT) 활용 연구(Pilot Study))

  • Kim, Seunghun;Ahn, Yujin;Sanzhar, Askaruly;Kim, Pilun;Jung, Woonggyu;Lee, Haekwang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.3
    • /
    • pp.247-254
    • /
    • 2017
  • Optical Coherence Tomography (OCT) is a non-invasive imaging method that utilizes the optical scattering and interference for visualizing the surface as well as cross-sectional structures of tissue. OCT has been used for diagnosing diseases in early stage in various medical fields, but an application in cosmetics is still at early stage. In this study, OCT was adopted to evaluate skin texture and wrinkle. Results showed similar patterns of evaluation with PRIMOS in the assessment using replica. In addition, OCT produced smaller errors at different angles compared to the PRIMOS in the assessment using 3-dimensional models of wrinkles. The resolution of the image was also high enough to differentiate the images of before and after the application of makeup products. Possible use of OCT in the evaluation of fine wrinkle assessment was studied in this research. Further development of methods is necessary to provide more evidences of the effectiveness.