• 제목/요약/키워드: Optical coherence

검색결과 341건 처리시간 0.02초

Low coherence 특성의 SLD를 이용한 2차원 OCT 영상 구현 (2-D OCT image implementation using low coherence SLD)

  • 정태호;박양하;오상기;김용평
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.290-291
    • /
    • 2003
  • Optical Coherence Tomography is a new medical dianostic imaging technology which can perform micron resolution cross-sectional or tomograpic imaging in biological tissue. In this paper, we analyze OCT system. And we have 2-dimensional OCT image implementation using low coherence SLD.

  • PDF

Measurement of Spatial coherence function and Directional coherence function of Propagating Laser Beam by using Wigner Distribution Function

  • Lee, Chang-Hyuck;Kang, Yoon-Shik;Noh, Jae-Woo
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.449-450
    • /
    • 2009
  • 위그너 분포 함수 측정을 통하여 진행하는 laser beam의 상관함수와 진행 특성들을 연구하였다. 위그너 분포 함수는 진행하는 laser beam의 total degree of coherence, beam quality parameter, 그리고 근접장 및 원거리장의 정보들을 보여준다. 위그너 분포 함수를 이용하여 공간상관 함수와 방향상관 함수를 구할 수 있으며, 이를 Schmidt mode decomposition을 이용하여 분석하면 laser beam의 보다 여러가지 특성들을 분석 할 수 있다. 이렇게 분석된 eigenmode들은 진행하는 laser beam의 보다 정확한 coherence 특성을 이해하게 해준다.

  • PDF

Polarization Sensitive Low Coherence Interferometer를 이용한 Glucose 농도 측정 (Measurement of Glucose concentration using Polarization Sensitive Low Coherence Interferometer)

  • 이상원;김법민
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.128-129
    • /
    • 2003
  • 최근 수년간 polarimetry, Raman spectroscopy, near infrared (NIR) absorption spectroscopy, NIR scattering, optoacoustics 등의 방법을 통하여 비침습적으로 Glucose의 농도를 측정하려는 연구가 많이 시도되었다. 일반적으로 이들 방법은 sensitivity 와 signal-to-noise ratio가 매우 낮고 복잡한 알고리즘이 요구되어져 glucose 농도 측정에 한계가 있음이 드러났다. 본 연구에서는 polarization sensitive optical coherence tomography (PS-OCT)에 사용되는 polarization sensitive low coherence inter-ferometer (PS-LCI) 기법을 이용하여 비침습적으로 glucose의 농도 측정을 가능하게 하는 시스템 개발에 중점을 두었다. (중략)

  • PDF

Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous Emission

  • Lee, Ju-Han;Jung, Eun-Joo;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.49-54
    • /
    • 2010
  • In this study, the use of a continuous-wave (CW) supercontinuum (SC) seeded by an erbium-doped fiber's amplified spontaneous emission (ASE) for optical-coherence tomography imaging is experimentally demonstrated. It was shown, by taking an in-depth image of a human tooth sample, that due to the smooth, flat spectrum and long-term stability of the proposed CW SC, it can be readily applied to the spectral-domain optical-coherence tomography system. The relative-intensity noise level and spectral bandwidth of the CW SC are also experimentally analyzed as a function of the ASE beam power.

Coherence Studies of Photons Emitted from a Single Terrylene Molecule Using Michelson and Young’s Interferometers

  • Yoon, Seung-Jin;Trinh, Cong Tai;Lee, Kwang-Geol
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.555-559
    • /
    • 2015
  • Coherence length (time) is a key parameter in many classical and quantum optical applications. Two interferometers – Michelson and Young’s double-slit – are used to characterize the temporal coherence of single photons emitted from single terrylene molecules. For quantitative analysis, a dispersion-related distortion in the interference pattern of a Michelson interferometer is carefully corrected by a simple dispersion compensation. Additionally, it has been demonstrated that Young’s interferometer can be used in temporal coherence studies at the single photon level with high accuracy. The pros and cons of the two systems are discussed. The measured coherence lengths in the two systems are consistent with one another under the self-interference interpretations.

광섬유 레이저에서의 광궤환에 대한 연구 (Study on Optical Feedback in Optical Fiber Laser)

  • 최규남
    • 한국정보통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.985-990
    • /
    • 2007
  • 코히런트 광섬유 센서의 해상도를 향상시키기 위하여 광원의 코히런스 길이를 향상시키는 방법에 대하여 연구하였다. 넓은 파장범위에 걸쳐서 레이저 광을 생성할 수 있고 발광 파장대역이 장거리 전송이 가능한 통신용 광섬유의 저 손실 대역인 광섬유 레이저의 코히런스 길이를 향상시키기 위하여 레이저의 광궤환 기법을 이용하였다. 본 논문에서는 광섬유 레이저의 단거리 및 장거리 광궤환 루프가 코히런스 길이에 미치는 영향을 Mach-Zehnder Interferometer를 이용하여 연구하였다. 광궤환 전력량과 광궤환 루프에서의 변조형태가 코히런스에 미치는 영향을 조사하였다. 주파수 천이도는 200m 길이차를 갖는 비대칭 간섭계에서의 위상간섭 정도를 측정하여 계산하였다. 광섬유 레이저에서 단거리 광궤환 루프는 450kHz/sec로 주파수 천이도를 축소시키는데 효과가 있었고 장거리 광궤환 루프는 50kHz/sec로 주파수 천이도를 더 향상시키는 효과가 있음을 알 수 있었다. 실제 코히런트 광센서에 응용 시 고감도 침입자 감지가 기대된다.

정현파로 구동되는 PZT 광경로 지연기를 이용한 광 간섭 단층촬영시스템 (Optical Coherence Tomography with Sinusoidal-Wave Drive an Optical Delay Line using Piezoelectrics Strecher)

  • 김영관;김용평
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.274-279
    • /
    • 2007
  • 광간섭 단층촬영(OCT)용으로 원통형 압전소자(PZT)와 단일모드 광섬유를 이용한 광경로 지연기를 제작하여 정현파로 구동하고 특성을 분석하였다. 제작한 OCT 시스템은 검침단과 기준단을 대칭 구동하는 이중 광경로 지연방식을 사용하였다. 정현파 구동을 통한 PZT 광경로 지연 방식은 삼각파 구동과 비교하여 입력파형의 첨두 부분에서의 비선형현상을 제거하여 높은 반복성을 나타냄을 보였고, 삼각파 구동으로는 불가능했던 부분을 영상화 할 수 있었다.