• Title/Summary/Keyword: Optical Interferometer

Search Result 614, Processing Time 0.03 seconds

Fabrication of Planar Type Optical Waveguide for the Application of Biosensor and Detection Characteristics of Staphylococcus Aureus (바이오센서용 평판형 광도파로 센서 제작 및 황색포도상구균 검출 특성)

  • Kim, Jun-Hyong;Yang, Hoe-Young;Yu, Chong-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.223-223
    • /
    • 2009
  • In this paper, designed and simulated Power Splitter (PS) integrated Mach-Zehnder interferometer (MZI) based planar type optical waveguide devices (which is called here a PS-MZI). The PS-MZI optical waveguide sensor was preceded by a Y-junction, which splits the input power between the sensor, and a reference branch, to minimize the effect of optical power variations. The PS-MZI optical waveguide sensor induced changing phases of the incident beam, which had fallen upon the waveguide through computer simulation, according to the small changes in the index of refraction, thus beam intensity was changed. The waveguide were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of PS-MZI optical waveguide sensor was performed by a conventional planar lightwave circuit (PLC) fabrication process. The PS-MZI optical waveguide that was fabricated to be applied as a biosensor revealed a low insertion loss and a low polarization-dependent loss. After having etched the over-clad at the sensor part in the MZI optical waveguide that was fabricated, Ti deposition was made on the adhesion layer, and then Au thin-film deposition was carried out thereon. In addition, its optical properties were measured by having changed the index of refraction oil at the sensing part of the MZI. To apply the planar type PS-MZI optical waveguide as a biosensor, a detection test for Staphylococcus aureus was conducted according to changes in concentration, having adopted Ti-alkoxide as ligand. The detection result of the S. aureus by the PS-MZI optical waveguide sensor was possible to the level of $10^1$ CFU/ml.

  • PDF

Development of Optic Balance Using Interference of Light (빛의 간섭 구조를 이용한 광 저울 개발)

  • Choi, Hoon;Park, Kyoung-Su;Lee, Jung-Ryul;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.127-131
    • /
    • 2004
  • In this paper, we proposed an optical balance using a Michelson Interferometer structure. The frequency of the interference signal is changed nonlinearly related with a weight to be measured, and this frequency change is processed by a processor to give a measured weight. Several measurements were performed and the good results were obtained with the fluctuation of about 1g.

  • PDF

Single Mode Lasing Characteristics in Multimode Interferometer-Coupled Semiconductor Square Ring Resonators (다중모드 간섭기를 이용한 반도체 이중사각형 링 공진기에서의 단일모드 발진 특성)

  • Jeong, Dal-Hwa;Moon, Hee-Jong;Hyun, Kyung-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • We report the spectral characteristics of Multimode Interferometer (MMI)-coupled semicondoctor square ring resonators. The epitaxial layers of the proposed semiconductor ring resonator consists of $1.55{\mu}m$ GaInAsP-InP multiple quantum wells. The lasing characteristics were observed by varying the structure parameters of the MMI-coupled square ring resonators. It is concluded that the MMI-coupled scheme selects a single spectral lasing mode in the double square ring cavities.

Single-mode optical fiber strain gauge (단일 모-드 광섬유 스트레인 게이지)

  • 이기완;김병교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1198-1203
    • /
    • 1991
  • A single w& optical fiber strain gauge subjected to the excited PZT-plate is presented which was obtained using a Mach-Zehnder interferometer. This paper has been performed the considerations to the experimental situation In which the dynamical behavior of a optical fiber strain gauge is illustrated. A comparison is reported between the dynamic response of a optical fiber strain gauge and the semiconductor strain gauge in the frequency range 5-50Hz. This result is shown in very good usage as the dynamical measurement of the low strain below l.mu..epsilon. by this system.

  • PDF

Improvement of Thermal Stability of Optical Current Sensors Based on Polymeric Optical Integrated Circuits for Quadrature Phase Interferometry (사분파장 위상 간섭계 폴리머 광집적회로 기반 광전류센서의 온도 안정성 향상 연구)

  • Chun, Kwon-Wook;Kim, Sung-Moon;Park, Tae-Hyun;Lee, Eun-Su;Oh, Min-Cheol
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.249-254
    • /
    • 2019
  • An optical current sensor device that measures electric current by the principle of the Faraday effect was designed and fabricated. The polarization-rotated reflection interferometer and the quadrature phase interferometer were introduced so as to improve the operational stability. Complex structures containing diverse optical components were integrated in a polymeric optical integrated circuit and manufactured in a small size. This structure allows sensing operation without extra bias feedback control, and reduces the phase change due to environmental temperature changes and vibration. However, the Verdet constant, which determines the Faraday effect, still exhibits an inherent temperature dependence. In this work, we tried to eliminate the residual temperature dependence of the optical current sensor based on polarization-rotated reflection interferometry. By varying the length of the fiber-optic wave plate, which is one of the optical components of the interferometer, we could compensate for the temperature dependence of the Verdet constant. The proposed optical current sensor exhibited measurement errors maintained within 0.2% over a temperature range, from 25℃ to 85℃.

Experimental Study on the Friction Effect of Viscosity Index Improver under EHL Contact Condition

  • Kong, Hyun-Sang;Jang, Si-Youl
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.91-92
    • /
    • 2002
  • Most studies of elsatohydrodynamic lubrication are oriented only to the measurement of film thickness itself with optical interferometer. In order to exactly investigate the characteristics of a certain lubricant under the condition of additives. especially for traction performance. it is also important to get the information of traction force as well. In this work. we developed the device for measuring friction force of EHL contact condition, which can trace the film thickness over the contact area with optical interferometer. To verify the validity of the measuring system, the friction force and film thickness under EHL condition are measured with the variation of additive ratios of viscosity Index improvers.

  • PDF

A Stable 40 GHz Pulse Train Generation by Pulse Repetition-Frequency Quadruplication Using a Fiber Fabry-Perot Interferometer

  • Ruan, Wan-Yong;Park, Jae-Hyun;Seo, Dong-Sun
    • Journal of IKEEE
    • /
    • v.12 no.4
    • /
    • pp.234-238
    • /
    • 2008
  • We demonstrate a simple method to generate a stable 40 GHz pulse train at 1550 nm by spectral filtering of a 10 GHz mode.locked pulse source using a fiber Fabry-Perot interferometer (FFPI). A high finesse FFPI with a 40 GHz free spectral range blocks successfully unwanted spectral components of a 10 GHz pulse source and passes only 40 GHz spaced spectral lines ensuring pulse repetition-frequency quadruplication of the input pulses.

  • PDF

Displacement measurement in nanometer region and calibration of transducers using combined optical and x-ray interferometer (광/엑스선 복합간섭계를 이용한 나노미터 영역의 변위 측정 및 trnasducer의 비선형 교정)

  • Park Jin-Won;Jo Jae-Gun;Byun Sang-Ho;Eom Cheon-Il
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.515-518
    • /
    • 2005
  • 현재 정밀한 길이를 측정하기 위해서는 광 간섭계를 이용한 측정기술이 주로 사용되어지고 있다. 이러한 광 간섭계의 발전과 더불어 이보다 더 높은 분해능을 얻기 위해 광파장보다 1000배 정도 짧은 엑스선을 이용한 변위 측정 기술개발이 진행되고 있다. 본 연구에서는 이러한 엑스선을 이용한 간섭계를 제작하고, 광 간섭계와 결합된 광/엑스선 복합간섭계를 구성하여 광 간섭계가 안고 있는 자체의 비선형성이 제거된 정밀 변위 측정 시스템을 구성하였다. 그 응용으로써, 제작된 광/엑스선 복합간섭계를 이용하여 나노미터 영역에 서 사용하는 transducer의 비선형성을 측정하였다.

  • PDF

Visual Cryptography based on Optical Interference (광학적 간섭현상을 이용한 시각 암호화 기법)

  • 이상수;김종윤;박세준;김수중;김정우
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.321-324
    • /
    • 2000
  • In this paper, we proposed a new visual cryptography scheme based on optical interference which improves the contrast and SNR of reconstructed images comparing with conventional visual cryptography method. We divided an binary image to be encrypted into n slides. To encrypt them, (n-1) random independent keys and one another random key by XOR process between four random keys were prepared. XOR between each divided image and each random key makes encrypted n encrypted images. From these images, encrypted binary phase masks can be made. For decryption all of phase masks should be placed together in the interferometer such as Mach-Zehnder interferometer.

  • PDF

Design of Precision Position Measuring System using Laser Interferometry (광간섭법을 이용한 정밀 위치측정 시스템 설계)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.145-149
    • /
    • 1997
  • A laser mesurement system, a modified Michelson interferometer,which can accurately measure high speed length and position of servomechanisms by detecting a phase shift in the measurement beam using an optical interference was developed. A frequency stabilized laser source and a 20 fold frequency interpolation and digitizing circuit were applied to the system. The refractive index of the ambient air was calibrated through the Edlen's formula. The system achieved a resolution of .lambda./40,16nm, a maximum allowable measurement speed of 600 mm/sec, and a length measurement range of 1500mm. Performance of the system was evaluated on the machining center in short and long length measurements

  • PDF