• Title/Summary/Keyword: Optic lens

Search Result 100, Processing Time 0.029 seconds

Image Quality Evaluation and Tolerance Analysis for Camera Lenses with Diffractive Element

  • Lee, Sang-Hyuck;Jeong, Ho-Seop;Jin, Young-Su;Song, Seok-Ho;Park, Woo-Je
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.105-111
    • /
    • 2006
  • A novel image quality evaluation method, which is based on combination of the rigorous grating diffraction theory and the ray-optic method, is proposed. It is applied for design optimization and, tolerance analysis of optical imaging systems implementing diffractive optical elements (DOE). The evaluation method can predict the quality and resolution of the image on the image sensor plane through the optical imaging system. Especially, we can simulate the effect of diffraction efficiencies of DOE in the camera lenses module, which is very effective for predicting different color sense and MTF performance. Using this method, we can effectively determine the fabrication tolerances of diffractive and refractive optical elements such as the variations' in profile thickness, and the shoulder of the DOE, as well as conventional parameters such as decenter and tilt in optical-surface alignments. A DOE-based 2M-resolution camera lens module designed by the optimization process based on the proposed image quality evaluation method shows ${\sim}15%$ MTF improvement compared with a design without such an optimization.

Spontaneous ophthalmic diseases of Beagles in Korea (국내 Beagle견의 안과질환)

  • Kim, Bong-kyeong;Yun, Young-min;Seong, Je-kyung;Seo, Kang-moon
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.113-121
    • /
    • 2001
  • Beagle is one of the most popular laboratory animal in a dog. We investigated the incidence of spontaneous ophthalmic disease in Beagles in order to make basic data for quality control of Beagles in Korea. We surveyed 389 beagles from 3 different farms. The average prevalence rate of ophthalmic diseases was 19.3%. The prevalence rate of cataracts was higher than any other ophthalmic diseases, 7.5% and then in order of corneal scar(2.1%), retinal hemorrhage(1.5%), post-inflammatory retinal change(1.5%), cherry eye(1.0%), distichiasis(0.8%), entropion(0.8%), hypoplastic optic disc(0.8%), conjunctivitis(0.5%), retinal dysplasia(0.5%), asteroid hyalosis(0.3%), congenital eye anomaly(0.3%), corneal lipidosis(0.3%), conjunctival hemorrhage(0.3%), lens capsule pigmentation(0.3%), persistent hyperplastic primary vitreous (0.3%), posterior synechia(0.3%), eyelid tumor(0.3%) and uveal cyst(0.3%) were diagnosed. There was a slight difference between male(24.8%) and female(17.4%) in prevalence rate of ophthalmic disease. The incidence of spontaneous ophthalmic disease was increased with age. These data would be useful for using Beagles as laboratory animals and standard reference for quality control of dogs.

  • PDF

Micromachining Characteristics inside Transparent Materials using Femtoseocond Laser Pulses (펨토초 레이저에 의한 투명 유리내부 미세가공특성)

  • Nam Ki-Gon;Cho Sung-Hak;Chang Won-Seok;Na Suck-Joo;Whang Kyung-Hyun;Kim Jae-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.190-196
    • /
    • 2006
  • Transparent materials are widely used in the fields of optic parts and bio industry. We have experiment to find out the characteristics of the micromachining inside transparent materials using femtosecond laser pulses. With its non-linear effects by very high peak intensity, filament (plasma channel) was formed by the cause of the self-focusing and the self-defocusing. Physical damage could be found when the intensity is high enough to give rise to the thermal stress or evaporation. At the vicinity of the power which makes the visible damage or modification, the structural modification occurs with the slow scanning speed. According to the polarization direction to the scanning direction, the filament quality is quite different. There is a good quality when the polarization direction is parallel to the scanning direction. For fine filament, we could suggest the conditions of the high numerical aperture lens, the short shift of focusing point, the low scanning speed and the low power below 20 mW. As the examples of optics parts, we fabricated the fresnel zone plate with the $225{\mu}m$ diameter and Y-bend optical wave guide with the $5{\mu}m$ width.

Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor (UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

Evaluating efficiency of Vertical MLC VMAT plan for naso-pharyngeal carcinoma (비인두암 Vertical MLC VMAT plan 유용성 평가)

  • Chae, Seung Hoon;Son, Sang Jun;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose : The purpose of the study is to evaluate the efficiency of Vertical MLC VMAT plan(VMV plan) Using 273° and 350° collimator angle compare to Complemental MLC VMAT plan(CMV plan) using 20° and 340° collimator angle for nasopharyngeal carcinoma. Materials & Methods : Thirty patients treated for nasopharyngeal carcinoma with the VMAT technique were retrospectively selected. Those cases were planned by Eclipse, PO and AcurosXB Algorithm with two 6MV 360° arcs and Each arc has 273° and 350° of collimator angle. The Complemental MLC VMAT plans are based on existing treatment plans. Those plans have the same parameters of existing treatment plans but collimator angle. For dosimetric evaluation, the dose-volumetric(DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. MCSv(Modulation complexity score of VMAT), MU and treatment time were also compared. In addition, Pearson's correlation analysis was performed to confirm whether there was a correlation between the difference in the MCSv and the difference in each evaluation index of the two treatment plans. Result : In the case of PTV evaluation index, the CI of PTV_67.5 was improved by 3.76% in the VMV Plan, then for OAR, the dose reduction effect of the spinal cord (-14.05%) and brain stem (-9.34%) was remarkable. In addition, the parotid glands (left parotid : -5.38%, right : -5.97%) and visual organs (left optic nerve: -4.88%, right optic nerve: -5.80%, optic chiasm : -6.12%, left lens: -6.12%, right lens: -5.26%), auditory organs (left: -11.74%, right: -12.31%) and thyroid gland (-2.02%) were also confirmed. The difference in MCSv of the two treatment plans showed a significant negative (-) correlation with the difference in CI (r=-0.55) of PTV_54 and the difference in CI (r=-0.43) of PTV_48. Spinal cord (r=0.40), brain stem (r=0.34), and both salivary glands (left: r=0.36, right: r=0.37) showed a positive (+) correlation. (For all the values, p<.05) Conclusion : Compared to the CMV plan, the VMV plan is considered to be helpful in improving the quality of the treatment plan by allowing the MLC to be modulated more efficiently

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Study of the Acceptable Tolerances of a Window Hermetic Optical Connector (Window 밀폐형 광 커넥터의 허용 공차에 관한 연구)

  • Jeon, Woo-Sung;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.5
    • /
    • pp.210-217
    • /
    • 2022
  • In this paper, a study is conducted on the acceptable tolerance of an alignment device to reduce the optical loss caused by the alignment tolerance of a window hermetic optical connector. To increase the transmission distance of optical signals and fiber-optic communication systems, it is necessary to maintain and improve the high optical efficiency of the connectors used to bond optical fibers. In the case of the window hermetic optical connector, the optical system is aligned through an alignment device. At this time, since the two connectors are used together, each component is fixed, and further alignment is impossible. The alignment tolerance of the housing system and pin used to align the optical system of the connector causes optical loss, leading to serious problems in the fiber-optic communication system. Thus, to find the acceptable tolerance required for manufacturing the optical-connector alignment device, tolerance analysis is performed on the components of the optical connector, such as the ball lens and the window. We also implement single-mode and multimode optical-connector systems, respectively. Based on the results, we determine an acceptable tolerance value for the alignment device.

Ultrastructure of the Eye in the Snail, Incilaria fruhstorferi (산민달팽이 (Incilaria fruhstorferi) 눈의 미세구조)

  • Chang, Nam-Sub;Han, Jong-Min;Lee, Kwang-Joo
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.363-377
    • /
    • 1998
  • After the investigation on the eye of Incilaria fruhstorieri with light and electron microscopes, the following results were obtained. The eye of Incilaria fruhstorferi comprises cornea, lens, vitreous body, retina, and optic nerve inward from the outside. Cornea is composed of squamous, cuboid, columnar and irregular cells, which appear to be light due to their low electron density. In their cytoplasms, glycogen granules, multivesicular body, and nucleus were observed. Vitreous body, located behind non-cellular transparent lens, is filled with long and short microvilli protruding from the retinal epithelia. Retinal epithelium, the organ to perceive objects, is divided into four parts; microvillar layer pigment layer, nuclear layer, and neutrophils layer, from the apical portion. Microvillar layer consists of the type-I photoreceptor cells and pigmented granule cells. In the apical portion of their cytoplasms, long microvilli (length, $19{\mu}m$) , short microvilli (length, $8{\mu}m$), and rolled microvilli grow thick in the irregular and mixed forms. Photoreceptor cells are classified into type-I and type-II, according to their structures. The type-I cell has the apical portion rising roundly like a fan and the lower part which looks like the helve of a fan. In the cytoplasm of the apical portion, there are clear vesicles, cored vesicles, ovoid mitochondria, and microfilaments, and in the cytoplasm of the lower part, photic vesicles with their diameters about 60nm aggregate densely. The type-II photoreceptor cell, located at the lower end of the type-I cells, has a very large ovoid nucleus 3nd no microvilli. In the cytoplasm of the type-II cell, the photic vesicles with sizes 60nm aggregate more densely than in the cytoplasm of the type-I cell. Pigmented cells are classified into type-A and type-B, according to their structures. The type-A is identified to be a large cell containing round granules (diameter, $0.5{\mu}m$) of very high electron density, while the type-B is identified as a small cell where the irregular granules (diameter, $0.6{\mu}m$) of a little lower electron density amalgamate. Nuclear layer ranges from the bottom of pigment layer to the top of the capsule, and contains three kinds of nuclei (nuclei of the type-II photoreceptor cell, pigmented granule cell, and accessory neuron). The capsules covering the outmost part of the eyeball are composed of collagenous fiber and three longitudinal muscle layers (the thickness of each longitudinal muscle layer, $0.4{\mu}m$) and thick circular muscle layer (thickness, $0.3{\mu}m$). Around the capsules, there is a neurophile layer consisting of neurons and nerve fibers. Each neuron has a relatively large ovoid nucleus for its cytoplasm, and in the karyosome, large lumps of keterochromatin form a wheel nucleus.

  • PDF

Importance of Oxidative Stress in Ocular Dysfunction (안구의 기능이상에 대한 산화스트레스의 중요성)

  • Lee, Ji Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.103-109
    • /
    • 2008
  • Purpose: This review illustrates an importance of oxidative stress caused by reactive oxygen species (ROS) and reactive nitrogen species (RNS) generation in association with eye disease, especially of cataract, and discusses an important role of lipid peroxide as a mediator of oxidative stress-related ocular dysfunction. Methods: Oxidative stress, resulted from the cellular production of ROS and RNS, is known to cause various forms of cellular damages such as protein oxidation, DNA breaks, apoptosis, and lipid peroxidation. These damages can be developed to human diseases. Accumulating evidence strongly suggests that continuous or constant exposure of eye tissues to oxidative stress is a main cause of cataractogenesis. Therefore, we investigated the action of oxidative stress in ocular dysfunction. Results: The ocular lens is continuously attacked by ROS inevitable generated from the process of cellular metabolism and the chronic exposure to ultraviolet. Excessive generation of ROS, resulting in degradation, oxidation, crosslinking and aggregation of lens proteins, is regarded as an important factor in development of cataract. Conclusions: These oxidative stress and oxidant/antioxidant imbalance produces the excess ROS which can lead to eye dysfunction. Even though known results, it should be noted that there is limited information on the molecular mechanism which can be better defined with the interrelation of oxidative stress and optic abnormalities.

  • PDF

Design modification and structural behavior study of a CFRP star sensor baffle

  • Vinyas, M.;Vishwas, M.;Venkatesha, C.S.;Rao, G. Srinivasa
    • Advances in aircraft and spacecraft science
    • /
    • v.3 no.4
    • /
    • pp.427-445
    • /
    • 2016
  • Star sensors are the attitude estimation sensors of the satellite orbiting in its path. It gives information to the control station on the earth about where the satellite is heading towards. It captures the images of a predetermined reference star. By comparing this image with that of the one captured from the earth, exact position of the satellite is determined. In the process of imaging, stray lights are eliminated from reaching the optic lens by the mechanical enclosures of the star sensors called Baffles. Research in space domain in the last few years is mainly focused on increased payload capacity and reduction in launch cost. In this paper, a star sensor baffle made of Aluminium is considered for the study. In order to minimize the component weight, material wastage and to improve the structural performance, an alternate material to Aluminium is investigated. Carbon Fiber Reinforced Polymer is found to be a better substitute in this regard. Design optimisation studies are carried out by adopting suitable design modifications like implementing an additional L-shaped flange, Upward flange projections, downward flange projections etc. A better configuration of the baffle, satisfying the design requirements and achieving manufacturing feasibility is attained. Geometrical modeling of the baffle is done by using UNIGRAPHICS-Nx7.5(R). Structural behavior of the baffle is analysed by FE analysis such as normal mode analysis, linear static analysis, and linear buckling analysis using MSC/PATRAN(R), MSC-NASTRAN(R) as the solver to validate the stiffness, strength and stability requirements respectively. Effect of the layup sequence and the fiber orientation angle of the composite layup on the stiffness are also studied.