• Title/Summary/Keyword: Ophthalmic optometry laboratory

Search Result 7, Processing Time 0.016 seconds

Current Status of Ophthalmic Optometry Laboratory Personnel in Korea, Japan, and the United States (한국, 일본, 미국 안과검사인력의 현황)

  • Okhwan, Jeon;Junbeom, Park;Dae Jin, Kim;Dae Eun, Kim;Cheol, Moon;Bon-Kyeong, Koo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.285-292
    • /
    • 2022
  • The education and training system, the ISCO (International Standard Classification of Occupations), and the legal systems of Japan and the United States consider all ophthalmic optometry laboratory personnel as ophthalmologists. They encompass optometrists, orthoptists, optometric technicians, and ophthalmic medical technicians. Data retrieved from the KOSIS (Korean Statistical Information Service) revealed that the number of opticians associated with the department of ophthalmology in 2022 could be appraised by classifying their medical institutions; contrarily, the number of clinical laboratory technologists could not be assessed. However, the current research investigated a general tertiary hospital and determined that clinical laboratory technologists outnumber opticians. Classification in Korea is based on ophthalmic optometry laboratory personnel, ISCO, ISCED (International Standard Classification of Education), the medical service act, the act on medical service technologists, and the higher education act. These results cannot be compared to the optometrists evaluated in the United States. Ophthalmology is a suitable profession for optometric technologists and technicians who perform under the instructions of ophthalmologists and optometrists. The field of eye healthcare would be benefitted by assigning the management based on their qualification according to the requirement of the job title, such as 'Clinical Optometry Technologist' to be given to clinical laboratory technologists and opticians who work in the ophthalmic optometry laboratories after obtaining a private qualification endowed by the Korean Ophthalmological Society and the Korean Optometry Society.

THE CONTACT LENS RELATED CASE REPORTS IN PEDIATRIC POPULATION I -Congenital Cataract With Divergent Squint (콘택트렌즈에 연관된 소아집단 I 에서 증례 보고 -개산성 사시를 가지는 선천성 백내장)

  • Chen, Ai-Hong;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.75-79
    • /
    • 2004
  • Some ocular complications were connected to the contamination by the contact lens related. Especially the most cause of ocular complications was a microorganism from several processing of infections. Therefore the patients stopped the contact lens wear immediately by the side effects of ocular pathology. We had analyzed the microorganism from the laboratory. It was identified as mixed growth of the Chryseamonas meningosepticum and Enterobacter sp.

  • PDF

The Bacterial Contamination in Glasses for Vision Correction (시력 교정용 안경의 세균 오염)

  • Kim, Heung-Soo;Hwang, Seock-Yeon;Yun, Chi-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.67-73
    • /
    • 2013
  • Purpose: Recently, bacterial contamination of equipment and accessories required for vision correction has become a main causal factor in ophthalmic diseases. Thus, We investigated on both the actual condition of bacterial contamination from glasses of vision correction. Methods: Investigation of microorganisms was carried out with a group of 145 glasses wearers, composed of 36 elementary school students, 37 middle school students, 38 high school students, 10 college students, and 32 aged men. Results: Seventeen species of bacteria are detected from glasses of vision correction: B. cereus, B. licheniformis, Bacillus sp., CNS, Enterococcus sp., Escherichia coli, Proteus sp., Pseudomonas sp., Serretia sp., Streptococcus sp., Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus hemolyticus,, Acinetobacter sp., Enterobacter cloacae, GNR, and Pseudomonas aeruginosa. Among 17 species of bacteria, there are some potential causative agents for keratitis, corneal ulcer, Acute dacryocystitis, Orbital cellulitis, Periphlebitis retinae, Marginal blepharitis, and Acute conjunctivitis. Enterobacter cloacae, Pseudomonas aeruginosa and Staphylococcus epidermidis cause keratitis. Pseudomonas sp., and Staphylococcus aureus cause corneal ulcer. Staphylococcus aureus causes acute dacryocystitis, orbital cellulitis, periphlebitis retinae, marginal belpharitis. Streptococcus hemolyticus causes acute conjunctivitis. Conclusions: In summation, it is verified that hazardous, opportunistic and infectious microorganisms exist in glasses for vision correction. Ophthalmic diseases are predicted. Therefore, supplementary research on the development of a cleaning solution to cleanse the infection and of an effective method to remove microorganisms is required.

Adsorption Properties of the Lysozyme and Albumin with Physicochemical Properties of the Contact Lens (콘택트렌즈의 물리화학적 특성에 따른 라이소자임과 알부민의 흡착 특성)

  • Sung, Yu-Jin;Ryu, Geun-Chang;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.261-270
    • /
    • 2013
  • Purpose: Adsorption properties of lysozyme and albumin according to physiochemical properties of commercial contact lens classified with the FDA categories and a contact lens fabricated in the laboratory were investigated. Methods: The contact lens were prepared using HEMA(2-hydroxyethyl methacrylate) and TRIM(3-(trimethoxysilyl) propyl methacrylate) in a cast mold. Artificial tears containing lysozyme and albumin were prepared. We measured the amounts of protein adsorbed on the each lenses with varying adsorbed time (48 hour) and the pH range (6, 6.8, 7.4, 8.2, 9) of artificial tear. Amount of the proteins absorbed on the contact lenses were measured by using HPLC. Results: Time to reach the equilibrium of protein adsorption for silicone hydrogel lens was taken longer than hydrogel lens. The amount of adsorbed both lysozyme and albumin at equilibrium were greater for the hydrogel lens than the silicone hydrogel lens, and larger for the ionic lens than the non-ionic lens. Lysozyme was more adsorbed on the higher water content of contact lens, whereas albumin was more adsorbed on the lower water content of contact lens. Only lysozyme was adsorbed on the Group IV hydrogel lens of ionic higher water content. The adsorption of protein on contact lens increased with pH of artificial tears as close to the isoelectric point of each protein. Conclusions: The adsorption amount of lysozyme is more affected by the ionic strength of the contact lens surface than the water content of contact lens. Albumin adsorption is more affected by water content than the ionic strength of the contact lens surface. For the adsorption of proteins on the silicone hydrogel lens, the pore size, determined both by the number of Si atoms and the chemical structure of the silicone-containing monomers, as well as the polarity of contact lens should be also considered.

The contrast sensitivity change of circle contact lens's color by refraction error and illuminance (굴절이상도와 조도에 따른 써클콘택트렌즈의 색상 별 대비감도 변화)

  • Kim, Bo-Yun;Jung, Mi-A;Lee, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.273-279
    • /
    • 2018
  • This study researched how the refraction error and illumination influence to contrast sensitivity when we wear the circle contact lenses. The study population comprised 16 students and adults(5 of Male, 11 of Female). The study population comprised 16 students and adults(5 of Male, 11 of Female), We measured the contrast sensitivity on uncorrected vision, according to color of circle contact and change the illumination of laboratory. The contrast sensitivity by illumination decreased than unaided vision when they wore the color contact lenses and more increased mesopic than photopic. Compared between black and brown lenses, brown was higher the contrast sensitivity than black. Also emmetropia had significantly differences when we compared the contrast sensitivity of subjects who had emmetropia, myopia and myopia astigmatism whether refractive error has or not. Therefore, it is important to provide sufficient understanding and recognition of color contact lenses.

Comparison Among the Four Examination Methods for Dry Eye (OQAS test, TBUT, Schirmer Test, McMonnies test) (4가지 건성안 분석방법(OQAS test, TBUT, Schirmer test, McMonnies test)의 비교)

  • Park, Chang Won;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2015
  • Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.