• Title/Summary/Keyword: Ophthalmic

Search Result 1,478, Processing Time 0.019 seconds

The Global Status of Ophthalmic Education and Legislation (검안 교육과 법률의 국제적 현상)

  • Penisten, Douglas K.;Di Stefano, Anthony F.;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.73-84
    • /
    • 2003
  • This paper reviews the current status of ophthalmic education and legislation worldwide. The impact of the profession of optometry in providing eye and vision care in different regions of the world and strategic directions for optometry in Korea are discussed. The role of the World Council of Optometry in advancing the access and delivery of eye and Vision care is emphasized.

  • PDF

Measurement of the Phoria for Korean male and female adults by Maddox rod method (한국인 성인 남녀의 사위량측정)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.77-84
    • /
    • 1996
  • As the results of phoria measurement of Korean adults for 106 males and 55 females, the elevens (6.8%) are orthophoria, the nineties (55.9%) are esophoria and the fifty fives (34.2%) are exophoria respectively. Also the thirty threes (20.4%) are right hyperphoria against the left eye and the thirty eights (23.6%) are left hyperphoria against the right eye. Horizontal phoria is below $10{\Delta}$ mostly and vertical phoria is below $5{\Delta}$.

  • PDF

Relationship of Blur Circle and Height of the Retinal Image about visual Acuity in a Artificial Myopia (인위적 근시에서 망막상의 크기와 시력과의 관계)

  • Choi, Woon Sang;Sohn, Sung Eun;Kim, Jin Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.21-23
    • /
    • 2002
  • Compared visual acuity that is measured in a artificial myopia with the numerical calculation. Calculation included image's height as well as blur circle that is formed to retina. The blur circle calculated in geometrical optics model, and height of retinal image calculated by refractive power and visual acuity that is measured in a artificial myopia. Define this result as "blur ratio" about blur circle and height of retinal image, and investigated blur ratio relationship about visual acuity in a artificial myopia.

  • PDF

Comparative Study of Physical Properties of Functional Ophthalmic Hydrogel Lens Using Photo and Thermal Polymerization

  • Kim, Duck-Hyun;Seok, Jae-Wuk;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.10 no.3
    • /
    • pp.148-153
    • /
    • 2017
  • In this study, HEMA, MMA, AA, and EGDMA were used as basic combinations for manufacturing hydrophilic lenses for ophthalmic applications. In addition, AIBN (thermal polymerization initiator), 2H2M (photo polymerization initiator), and 3-hydroxypyridine (additive) were used to manufacture hydrophilic ophthalmic lenses through thermal polymerization and photo polymerization before their physical properties were measured. The results showed that when ophthalmic lenses were prepared via thermal polymerization and photo polymerization using 3-hydroxypyridine as an additive, their optical and physical properties and surface structures were different in each case, but they all satisfied the physical properties required for ophthalmic lenses.

The Importance of Optometric Education in Korea (한국에서 검안교육의 중요성)

  • Kim, Douk-Hoon;Sung, A-Young;Cullen, Anthony P.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.241-249
    • /
    • 2004
  • Since 1989 the number of nationally licensed ophthalmic and refracting opticians in Korea have increased. Currently, they are being educated in four universities, twenty six colleges and three graduate programs. It is innevitable that the growth of optometric education in Korea will be progressively influnced by worldwide influnces such as the World Council of Optometry(WCO), the World Health Organization (WHO), and the World Trade Organization(WTO). However, currently no standards for optometric education exist in Korea. Thus, the Korean Professional Councils of Ophthalmic Optics(KPCOO) must develope and provide standards for optometric education programs.

  • PDF

The Analysis of a Educational Objectives and a Curriculum of The Department of Ophthalmic Optics Departments of Two-Year Colleges (2년제 대학 안경광학과 교육목표와 교육과정 분석)

  • Ryu, Kyung Ho;Kim, Jung Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.65-70
    • /
    • 2007
  • This research aims at knowing educational objectives and understanding the whole departmental processes of two-year education programs of junior colleges in the field of ophthalmic optics. Our analyses can be categorized by on liberal art courses, compulsory subjects and optional subjects. The educational purpose of all the seven colleges was training the professional worker, meets well the educational requirements of two year college. All seven colleges' curriculum is open to the national licence examination subjects, but more academic credits are demended in eye examination of refraction, test of ocular function, professional sense of cultural subjects field, leadership in organization and course of marketing related subjects, and stronger relation with clinical examination are also required.

  • PDF

A study on the global optimization in the design of a camera lens-system (사진 렌즈계 설계에서 전역 최적화에 관한 연구)

  • Jung, Jung-Bok;Jang, Jun-Kyu;Choi, Woon-Sang;Jung, Su-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.121-127
    • /
    • 2001
  • While SVD and Gaussian elimination method were applied to the additive damped least squares(DLS), the convergence and the stability of the optimization process were examined in a triplet-type camera lens-system where the condition number is well conditioned. DLS with SVD method generated a suitable merit function but this merit function may be trapped in a local minimum by the nonlinearity of error function. Therefore, the least camera lens-system was further designed by the global optimization method is grid method, and this method is adopted to get merit function that convergent to global minimum without local minimum trapping.

  • PDF

Vibration Analysis Using Laser Speckle (레이저 스펙클을 이용한 진동분석)

  • Ruck, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo;Lee, Won-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.77-80
    • /
    • 2001
  • The purpose of this work is that by using speckle phenomena of low-level He-Ne laser, it analyzes the movement condition of surface elements on a substance vibrating. The lights from laser reflect against a copper plate and will be shown as speckles on a vibration board. If we vibrate these speckles by sound waves of a speaker installed on the back, the speckles change with various shapes. When a vibration board has a maximum vibration, the frequency becomes a dynamical resonance frequency and we can mark the changes of speckles at that time on a vibration board.

  • PDF

Protein Absorption and Characterization of Hydrogel Polymer Containing 2-Methacryloyloxyethyl Phosphorylcholine as Additive

  • Kim, Duck-Hyun;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.9 no.4
    • /
    • pp.249-254
    • /
    • 2016
  • This study evaluated the physical and optical characteristics of hydrophilic ophthalmic polymer with addition of 2-methacryloyloxyethyl phosphorylcholine in the basic hydrogel ophthalmic lens material, and in particular, the utility of 2-methacryloyloxyethyl phosphorylcholine as an ophthalmic contact lens material for ophthalmologic devices was investigated. In this study 2-methacryloyloxyethyl phosphorylcholine were used as additives. For the preparation of hydrogel lens 2-hydroxyethyl methacrylate, methyl methacrylate, acrylic acid and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. The physical properties of the produced polymers were measured as followings. The refractive index of 1.433~1.393, water content of 35.95~53.16%, contact angle of $70.6{\sim}51.24^{\circ}$, UVB transmittance of 81.2~82.4%, UV-B transmittance of 81.2~82.4% and visible transmittance of 91.4~92.2% were obtained. Also, in case of protein absorption, the measurement showed that absorbance of Reference and MPC-10 sample was 0.2598 and 0.2250 respectively. Based on the results of this study, ophthalmic lens material containing 2-methacryloyloxyethyl phosphorylcholine is expected to be used usefully as a material for high wettability and inhibitor of protein adsorption for ophthalmic hydrogel lens.

An Optical Characteristic Research of a Netspec Lens (네츠팩 렌즈의 광학적 특성 연구)

  • Lee, Dong-Hee;Kim, Dae-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.85-90
    • /
    • 2003
  • A Netspec lens has the form having the 2-dimensional mesh coating on a general ophthalmic lens. It is known that it makes the ophthalmic image see more clearly, reducing the ophthalmic fatigue and that the transmittance of it for ultraviolet and infrared rays is lower. We need to prove this characteristic scientifically. So, in this study, we applied the Kirchhoff's scalar wave theory to the Netspec lens and induced a transmittance expression. And we made the program of which simulation can explain the transmittance effect of the Netspec lens. Also, we tried the interpreting about the result of the simulation. Finally, we have known that this simulation program can be used to adjust the transmittance of the light according to the wavelength.

  • PDF