• 제목/요약/키워드: Operator dose

검색결과 51건 처리시간 0.025초

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

국내 원전 종사자의 방사선량 : 2009-2013 (Radiation Exposure on Radiation Workers of Nuclear Power Plants in Korea : 2009-2013)

  • 임영기
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.162-167
    • /
    • 2015
  • 후쿠시마 원전 사고로 인한 우리나라 장기 전력수급정책에 대한 대중의 저항 및 불안감이 존재하고 있다. 고리 원전 1호기에 대한 정부의 영구정지 결정과 설계수명이 끝난 월성 원전 1호기의 계속운전 시행 반대, 고리 원전 인근 주민의 갑상선암 논란 등 원전 운영으로 인한 국내외 여건이 위기를 맞이하고 있다. 이러한 상황에서 원전운영능력과 안전은 여러 가지 지표들이 있지만, 원전의 방사선안전관리 능력, 특히 방사선피폭량을 중심으로 상세 분석과 논의가 필요하다. 분석대상과 방법으로는 최근 5년간 원전의 피폭 방사선량을 분석하고, 유관한 방사선 작업종사자군과 방사선 피폭량 추이를 비교 평가하였고, 세계 주요 원전 국의 개인당 연간 평균방사선량도 비교 분석하였다. 분석결과 방사선차폐와 방호조치등 총체적인 방사선량 저감화 계획과 연구를 통해 방사선피폭량을 저감하고 있음을 확인하였다. 연간선량한도한도인 50 mSv, 5년간 100 mSv를 초과한 방사선작업 종사자는 없었으며, 이는 방사선구역 출입시 자동화에 따른 출입제한과 관리선량 제한치를 연간선량한도의 60%미만으로 설정하는 등 다양한 방사선안전관리 체계를 확보하고 있음이 확인되었다. 원자로형별 운영형태에 따른 방사선피폭 유형은, 중수로 원전의 총 피폭대비 정상 운전시 방사선피폭비율이 경수로 원전보다 6.2 % 높게 나타났다. 이는 중수로 원전이 정상운전시 방사선피폭 작업이 많음을 확인하였다. 또한 세계원자력발전사업자협의회 성능평가지표(World Association of Nuclear Operators performance indicators, WANO PI)에 의하면, 2013년도 주요 원전보유국의 연간 호기당 집단선량은 우리나라가 527 man-mSv로 가장 우수한 실적을 보였으며, 세계평균치인 725 man-mSv의 73% 수준을 보이는 것으로 나타났다. 개인당 연간 방사선피폭량은 종사자의 약 80%가 일반인의 선량한도인 1 mSv 미만이며, 개인당 평균선량 역시 0.82 mSv로 매우 낮은 수준을 보였다. 유관 기관의 방사선작업 종사자와 비교해보면, 2013년 기준으로 방사선안전재단에 등록된 관련 업종 방사선작업 종사자의 개인당 평균선량은 1.07 mSv에 비해 77% 수준이며, 비파괴 검사기관 종사자의 개인 평균선량 3.87 mSv의 21% 수준을 보였다. 결론적으로 원전의 피폭 방사선량은 이상적으로 저감하는 추이를 보이고 있으나, 더 이상 낮추는 것은 한계가 있을 것으로 판단된다. 그러나 원전 주변 주민이 심리적인 불안감, 전원개발계획에서 원전의 비중을 감안할 때, 최적의 원전 상황을 평가하는 지표인 방사선안전관리 능력은 각종 통계를 기반으로 하는 정보 제시 및 총체적인 방사선량 저감화 추진이 필요할 것으로 판단된다.

Hybrid Filter Based on Neural Networks for Removing Quantum Noise in Low-Dose Medical X-ray CT Images

  • Park, Keunho;Lee, Hee-Shin;Lee, Joonwhoan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제15권2호
    • /
    • pp.102-110
    • /
    • 2015
  • The main source of noise in computed tomography (CT) images is a quantum noise, which results from statistical fluctuations of X-ray quanta reaching the detector. This paper proposes a neural network (NN) based hybrid filter for removing quantum noise. The proposed filter consists of bilateral filters (BFs), a single or multiple neural edge enhancer(s) (NEE), and a neural filter (NF) to combine them. The BFs take into account the difference in value from the neighbors, to preserve edges while smoothing. The NEE is used to clearly enhance the desired edges from noisy images. The NF acts like a fusion operator, and attempts to construct an enhanced output image. Several measurements are used to evaluate the image quality, like the root mean square error (RMSE), the improvement in signal to noise ratio (ISNR), the standard deviation ratio (MSR), and the contrast to noise ratio (CNR). Also, the modulation transfer function (MTF) is used as a means of determining how well the edge structure is preserved. In terms of all those measurements and means, the proposed filter shows better performance than the guided filter, and the nonlocal means (NLM) filter. In addition, there is no severe restriction to select the number of inputs for the fusion operator differently from the neuro-fuzzy system. Therefore, without concerning too much about the filter selection for fusion, one could apply the proposed hybrid filter to various images with different modalities, once the corresponding noise characteristics are explored.

하악 매복 제3대구치 발치 시 Articaine HCl과 Lidocaine HCl의 국소마취 효능에 대한 비교연구 (Comparative Study for the Anesthetic Efficacy between Articaine HCl and Lidocaine HCl during the Surgical Extraction of Bilateral Mandibular Impacted Third Molars)

  • 이원영;서광석;김현정;염광원;박창주
    • 대한치과마취과학회지
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2004
  • Background: Articaine, a new amide-type local anesthetic, was recently commercially available in Korea. The purpose of this study was to compare the anesthetic efficacy between articaine HCl and lidocaine HCl for the surgical extraction of bilateral mandibular impacted third molars. Patients and Methods: Forty young and healthy patients with bilateral impacted third molars were selected with permission. Randomly, one side of impacted third molar was operated under local anesthesia using 4% articaine and the other side under 2% lidocaine after 1 or 2 week recovery time. Intraoperative pain was evaluated via 0-10 cm visual analog scale (VAS) by both the patient and operator immediately after the operation. After 1 day and 7 days, the complications of local anesthesia were checked. Results: The pain VAS scores in articaine group, evaluated by both the patient and operator, were lower than those in lidocaine group, but they were not statistically significant (P = 0.44 and 0.54, respectively). The incidence of complications of local anesthesia between articaine and lidocaine was similar. Conclusion: In this study, articaine showed at least equal efficacy compared to lidocaine. The further dose-controlled study with more pharmacokinetic parameters will be needed.

  • PDF

냉각재(冷却材) 상실사고시(喪失事故時) 1300 MWe 급(級) PWR원전(原電) 주제어실(主制御室)의 선량평가(線量評價) (A Control Room Dose Assessment for a 1300 MWe PWR Following a Loss of Coolant Accident)

  • 장시영;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.34-45
    • /
    • 1989
  • 프랑스의 1300 MWe 급(級) 표준(標準) P'4형 PWR 원전(原電)의 일차냉각재상실사고(一次冷却材喪失事故)(LOCA)시(時) 원전(原電) 주제어가내(主制御家內) 운전원(運轉員)에 대한 고사선(故射線) 피습선량(被濕線量)을 계산하여 주제어실(主制御室)의 체류안전성(滯留安全性)을 평가(評價)하였다. 본(本) 평가(評價)에서 사용(使用)된 제가정(諸假定)은 프랑스의 표준안전성분석보고서(漂準安全性分析報告書)에 따랐다. 본(本) 평가(評價)를 위하여 LOCA 사고시(事故時) 원자로건물외(原子爐建物外)로 방출(放出)되는 방사핵종(放射核種)의 방사능(放射能), 주제어실(主制御室)에서의 체적인자(體積因子) 및 제어실내(制御室內) 운전원(運轉員)의 전신(全身) 및 갑상선(甲狀膳) 피폭선량(被爆線量)을 사고발생후(事故發生後) 30일까지 전산(電算)할 수 있는 간단한 전산(電算)프로그램, COREX를 개발(開發)하였다. 본(本) 연구(硏究)에서 얻어진 계산결과(計算結果)는 대체적으로 프랑스의 EDF(불란서 전력주식회사(電力株式會社) 에서 제안(提案)한 결과(結果)와 대체적으로 잘 일치(一致)하였으나, 전신외부피폭선량(全身外部被爆線量)의 값은 일부(一部) 체적인자(體積因子) 값의 차이로 인(因)하여 일부 편차(偏差)를 보였다.

  • PDF

Comparison of pretreatment gabapentin and pregabalin to control postoperative endodontic pain - a double-blind, randomized clinical trial

  • Verma, Jayeeta;Verma, Sidharth;Margasahayam, Sumanthini V
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권5호
    • /
    • pp.377-385
    • /
    • 2022
  • Background: Postoperative endodontic pain is an enigma for the dentist. This study aimed to evaluate the analgesic effect of 300 mg gabapentin or 75 mg pregabalin in reducing postoperative endodontic pain compared with a placebo. Methods: Ninety patients who needed root canal treatment with an initial numerical rating scale (NRS) pain score of > 4 (T0) were randomly divided into three groups (n=30). Patients were then administered either 300 mg gabapentin (group A), 75 mg pregabalin (group B), or a placebo (group C) 30 min prior to the start of endodontic treatment. A single operator performed single-visit endodontics, and pain was evaluated immediately after endodontic treatment (T1) and at 4 h (T2), 8 h (T3), 12 h (T4), 24 h (T5), 48 h (T6), and 72 h (T7) using the NRS. Ibuprofen/paracetamol (400 mg/325 mg) was administered as a rescue dose if needed. Results: Pregabalin performed significantly better when compared with gabapentin at all time points except at 72 h after treatment (P=0.170). The placebo group showed significantly higher pain scores than the other two groups. The percentage of pain relief was maximum for pregabalin (92.1%), followed by gabapentin (87.6%) and placebo (69.1%) at 72 h after treatment completion. Conclusion: This study showed that pretreatment with a single dose of pregabalin and gabapentin both had greater analgesic effects than a placebo. They can be effectively used to reduce postoperative endodontic pain.

Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰 (A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume)

  • 김진구;함준철;오신현;강천구;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.20-26
    • /
    • 2020
  • 핵의학이란 방사성동위원소 추적자를 인체에 투여하여 관심장기에 대한 형태학적인 정보와 생물학적이고 기능적인 정보를 얻고 평가한다. Dose calibrator는 의료기관에서 단일 핵종의 방사능을 측정하기 위해 사용하는 장비이며, 방사성동위원소의 정확한 용량의 투여는 진단과 치료에 중요한 요인이다. 최근 정량분석을 위한 여러 시스템이 개발되고 있고 ERPF (Effective Renal Plasma Flow), GFR (Glomerular Filtration Rate) 등 정량분석이 필요한 검사에 있어서 정확한 투여 용량 및 재현성 있는 측정이 중요해지고 있다. 따라서 본 논문을 통해 Dose calibrator의 측정 깊이와 용량에 따른 선량 값의 성향을 알아보고 적절한 측정 깊이 및 용량에 대해 알아 보고자 한다. 실험에 사용한 Dose calibrator는 CRC-15R과 CRC-15βeta (Capintec, New Jersey, USA)를 사용하였다. 선원으로는 표준선원(Standard source) 137Cs, 133Ba, 57Co를 사용하였고, 방사성 의약품은 99mTc-pertechnetate를 사용하였다. 표준선원은 측정 깊이만 변화하여 0 cm부터 15 cm까지 1 cm 깊이마다 15회씩 측정했고, 99mTc-pertechnetate의 경우에는 1 mL 주사기로 표준선원과 동일한 깊이로 실험을 진행했고, 용량의 변화를 고려하여 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL로 각 깊이마다 15회씩 측정했다. 표준선원인 137Cs, 133Ba, 57Co의 깊이의 변화에서는 모두 깊이에 따른 선량 값의 변화가 통계적으로 유의한 차이가 있었다(p<0.05). 99mTc-pertechnetate도 깊이에 따른 용량의 변화에서 선량 값이 모두 통계적으로 유의한 차이가 있었다(p<0.05). CRC-15R의 표준선원 비교 그래프에서 137Cs, 133Ba, 57Co는 Plateau를 그리기 시작한 2 cm에서 9 cm까지는 각 선원마다 비교시 통계적으로 유의한 차이가 없었다(p>0.05). CRC-15βeta의 표준선원 비교 그래프에서는 Plateau를 그리기 시작한 영역은 3 cm에서 9 cm로 통계적으로 유의한 차이가 없었다(p>0.05). 99mTc-pertechnetate의 그래프는 0.1 mL에서 1 cm에서 7 cm, 0.3 mL와 0.5 mL에서는 0 cm에서 7 cm, 0.7 mL에서는 0 cm에서 6 cm, 0.9 mL에서는 0 cm에서 5 cm에서 통계적으로 유의한 차이가 나타나지 않았다(p>0.05). 본 연구를 통해 방사성동위원소를 환자에게 주입하거나 정도관리를 진행 시 편차가 적고 재현성을 위해 신뢰할 수 있는 구간을 확인 할 수 있었다. 높이에 따른 변화가 가장 적은 Plateau의 구간이 0.3 mL 혹은 0.5 mL의 용량으로 0 cm 에서 7 cm의 깊이에서 측정한다면, 편차를 최소한으로 줄일 수 있을 것으로 사료된다. 표준선원의 경우에는 본 연구의 결과에 따라 장비마다 Plateau의 변화가 가장 적은 구간의 깊이에서 재현성 있게 측정하는 것이 중요하다고 생각된다. 적절한 구간을 찾아서 재현성 있는 검사를 시행하면 검사의 품질향상 및 피폭선량저감 그리고 진단능을 높이는데 이바지 할 것이라고 생각된다.

월성 1호기 주기적안전성평가 - 기체 및 액체 방사성폐기물에 의한 환경영향 (Periodic Safety Review of Wolsong Unit 1 - Environmental Impact as gaseous and liquid effluents)

  • 김성민;이은미;김미자;이갑복;정양근;엄희문
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.455-462
    • /
    • 2003
  • 원자력법에 의해 국내 모든 가동원전은 10년마다 주기적안전성평가를 이행하고 있다. 원자력법 시행규칙 제19조의 2에 제시된 환경영향 분야의 평가는 원자로시설의 환경영향 감시계획이 적절히 수립되어 이행되고 있는지를 확인하는 것이다. 평가결과 월성 1호기 가동에 따른 환경영향은 전반적으로 기술기준을 만족하였으며, 평가기준일까지 월성 1호기 운영으로 인해 주변 주민이 받는 방사선량은 제한치 이내에서 안전하게 관리되는 것으로 확인하였다.

  • PDF

PROLONGATION OF THE BOR-60 REACTOR OPERATION

  • IZHUTOV, ALEXEY L.;KRASHENINNIKOV, YURI M.;ZHEMKOV, IGOR Y.;VARIVTSEV, ARTEM V.;NABOISHCHIKOV, YURI V.;NEUSTROEV, VICTOR S.;SHAMARDIN, VALENTIN K.
    • Nuclear Engineering and Technology
    • /
    • 제47권3호
    • /
    • pp.253-259
    • /
    • 2015
  • The fast neutron reactor BOR-60 is one of the key experimental facilities worldwide to perform large-scale tests of fuel, absorbing, and structural materials for advanced reactors. The BOR-60 reactor was put into operation in December 1969, and by the end of 2014 it had been operating on power for ~265,000 hours. BOR-60 still demonstrates potential capabilities to extend the lifetime of sodium-cooled fast reactors. The BOR-60 lifetime should have expired at the end of 2014. Over the past few years, a great scope of work has been performed to justify the possibility of extending its lifetime. The work included inspection of the equipment conditions, calculations and experimental research on operating parameters and the conditions of nonremovable components, investigation of the structural material samples after their long-term operation under irradiation, etc. Based on the results of the work performed, the residual lifetime was evaluated and the reactor operator made a decision to extend the lifetime period of the BOR-60 reactor. After considering both a set of documents about the reactor conditions and the positive decision of independent experts, the Regulatory Authority of the Russian Federation extended the BOR-60 operating license up to 2020.

Deltamethrin에 노출된 흰쥐의 뇨 중 3-PBA 검출 및 노출상관성 (The Correlation Between Deltamethrin Exposure and Urinary 3-PBA Concentrations in Rats)

  • 김아름누리;전경미;박경훈;문병철;노진호;백민경
    • 한국환경농학회지
    • /
    • 제36권4호
    • /
    • pp.293-298
    • /
    • 2017
  • BACKGROUND: Pyrethroids (PYRs) are a widely used insecticide in agriculture and household area. In mammals, PYRs such as deltamethrin is metabolized to 3-phenoxybenzoic acid (3-PBA) in liver that is mainly excreted in urine. This study is designed to single exposure of deltamethrin to rats in a dose-dependent manner and identify the correlation between deltamethrin exposure and its metabolite (3-PBA) in urine. METHODS AND RESULTS: Exposure levels of deltamethrin were control (0 mg/kg bw), low (0.0705 mg/kg bw), medium (0.705 mg/kg bw) and high (7.05 mg/kg bw) dose. Low concentration was derived by ussing Korea predictive operator exposure model (KoPOEM). Dermal exposure persisted for 6 h, and urine specimens were collected for 24 h. The urine matrix was removed after a series of procedures and 3-PBA was analyzed by gas chromatography/mass spectrometry. CONCLUSION: There was a strong correlation ($R^2=0.83$) between the amount of oral exposure to delta me thrin and urinary levelof3-PBAexcreted. In dermal exposure groups of deltamethrin except high-dose, also there was a good correlation between urinary 3-PBA and deltamethrin exposure, but not stronger than in oral deltamethrin exposure groups. Based on these results, therefore, the amount of 3-PBA in urine can be used as a good monitoring indicator that reflexing the exposure level of deltamethrin to human body.