• Title/Summary/Keyword: Operational modes

Search Result 207, Processing Time 0.03 seconds

A Basic Study on Mode of Operation for Maritime Autonomous Surface Ship

  • Jeong-Min, Kim;Hye Ri, Park
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.05a
    • /
    • pp.162-163
    • /
    • 2023
  • As the development of the 4th industiral revolution in the maritime industry has progressed, the technical development of autonomous ships, and the development of international regulations have been accelerated. In particular, the IMO Maritime Safety Committee(MSC) has established a road-map for the development of the non-mandatory goal-based MASS instrument(MASS Code) and started developing a non-mandatory MASS Code at MSC 105th meeting. Many countries are actively participating in the Correspondence Group on the development of MASS Code, and the development of detailed requirements for MASS functions in the MASS Code is underway. Especially, the concept of "Mode of Operation" for MASS functions was mentioned in the Correspondence Group for the first time, and it is expected that discussions on these modes will be conducted from the IMO MASS JWG meeting to held in April 2023. The concept of "Mode of Operation" will be useful in explaining MASS and MASS functions and will be discussed in the future for the development of MASS Code. This paper reviews the contents of the IMCA M 220 document, which provides guidelines on operating modes, to conduct research on the benchmark for setting the operating modes of MASS.

  • PDF

An application of operational deflection shapes and spatial filtration for damage detection

  • Mendrok, Krzysztof;Wojcicki, Jeremi;Uhl, Tadeusz
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1049-1068
    • /
    • 2015
  • In the paper, the authors propose the application of operational deflection shapes (ODS) for the detection of structural changes in technical objects. The ODS matrix is used to formulate the spatial filter that is further used for damage detection as a classical modal filter (Meirovitch and Baruh 1982, Zhang et al. 1990). The advantage of the approach lies in the fact that no modal analysis is required, even on the reference spatial filter formulation and other components apart from structural ones can be filtered (e.g. harmonics of rotational velocity). The proposed methodology was tested experimentally on a laboratory stand, a frame-like structure, excited from two sources: an impact hammer, which provided a wide-band excitation of all modes, and an electro-dynamic shaker, which simulated a harmonic component in the output spectra. The damage detection capabilities of the proposed method were tested by changing the structural properties of the model and comparing the results with the original ones. The quantitative assessment of damage was performed by employing a damage index (DI) calculation. Comparison of the output of the ODS filter and the classical modal filter is also presented and analyzed in the paper. The closing section of the paper describes the verification of the method on a real structure - a road viaduct.

An Analysis of the KOMPSAT-1 Operational Orbit Evolution Over 3 Years (아리랑 1호 임무기간 3년 동안의 궤도변화 분석)

  • Kim,Hae-Dong;Choe,Hae-Jin;Kim,Eun-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.40-50
    • /
    • 2003
  • The operational orbit evolution of the KOMPSAT-l over 3 years was analyzed. During LEOP, four orbit maneuvers were performed to obtain the optimized orbit and eight safe-hold modes happened. The effects of unpredictable occurrence of the safe-hold mode and the highest solar activity on the orbit evolution during the mission life were analyzed. The comparison of orbital elements between long-term predicted orbit and determined orbit from observed data was also performed. The operational orbit started from the optimized one was evolved within the boundary of the designed mission orbit except altitude and it was verified the sun-synchronous orbit was successfully maintained.

The Effects of Institutions on Foreign Subsidiary's Operational Mode of Korean Firms (진출국 제도가 해외 자회사 운영 방식 선택에 미치는 영향에 관한 연구)

  • Lee, Eung Sok
    • International Area Studies Review
    • /
    • v.22 no.1
    • /
    • pp.61-78
    • /
    • 2018
  • Foreign subsidiary operation modes can be broadly divided into horizontal subsidiaries and vertical subsidiaries. According to institutional theory, foreign subsidiary operation mode differs depending on the host country institution. This study examines the effects of formal and informal institution on the foreign subsidiary operational mode of Korean firms. As a result of the empirical analysis, the higher the cultural distance and the lower political risks, the more favored the vertical foreign operation mode than the horizontal foreign operation mode. On the other hand, the higher the economic freedom and the lower corruption, the more favored the horizontal foreign operation mode than the vertical foreign operation mode.

Advanced Offshore Pipelaying Analysis techniques Part 2 : Laybarge Methods (해저 파이프라인 가설 분석 기술)

  • Choe, Han-Seok
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.7-19
    • /
    • 1995
  • Various laybarge methods for offshore pipeline installation are introduced. Pipe stresses and strains during the installation are discussed with linear and nonlinear analysis methods. Several operational modes of offshore pipeline installation are described. Computer modelling techniques of the pipeline installation analyses are suggested.

  • PDF

Operational Problems and Policies in Korean Railway (우리나라 철도노선의 운영 비효율적 시설요인과 개선방향 연구)

  • Kim Hyun-Woong
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.1060-1063
    • /
    • 2005
  • Growing qualitative and cost-based competition with the roads and air modes will be oblige the railways to make better use of their existing infrastructure than present. Development and use of new signalling and safety systems and introduction of wide-area control systems may make it possible to operate railway efficiently. Therefore. a comprehensive series of measures must be developed in the fields of technology, planning and management, measures which can operate today's korean railway systems intelligently and achieve cost savings, better quality services and improved results.

  • PDF

Feasibility Study on the Personal Rapid Transit System (궤도 승용차 시스템의 기술, 경제성 평가)

  • 최재혁
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.17-24
    • /
    • 1999
  • To solve the traffic problems increased in the big cities, a lot of local transportation authorities are taking into account the New Transit system. But most of projects are pending due to the financial and technical issues. New Transit system has various kinds of characteristics in the view of system technology and operational features. The introduction of PRT system into the Korean market can be investigated through the comparison with other new transit modes.

  • PDF

The Modeling Analysis of the AT Forward Multi-Resonant Converter (AT 포워드 다중공진형 컨버터의 모델링 해석)

  • 김창선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.6-14
    • /
    • 2000
  • The high efficiency multi-resonant converter(MRC) is capable of operating at a high frequency because the losses are decreased due to the resonant tank circuit. Such a few MHz high frequency applications provide high power density[W/inch3] of the converter. However, the resonant voltage stress across the switch of the resonant tank circuit is 4∼5 times input voltage. This high voltage stress increases the conduction losses because of on-resistance of a MOSFET with higher rating. In this paper, the modeling analysis for the AT Forward MRC suggested to solve the these problems is discusses. The operational modes of the AT Forward MRC are divided to 8 equivalent modes according to the two switching sequences. Each mode analysis is covered using the equivalent circuits modeled over all of the paper. The operational principle of the resonant converter was verified through the experimental converter with 48[V] input voltage, 5[V]/50[W] output voltage/power and PSpice simulation. The measured maximum voltage, 5[V]/50[W] output voltage/power and PSpice simulation. The measure maximum voltage stress is 170[V] of 2.9 times the input voltage and the maximum efficiency is measured to 81.66%.

  • PDF

Analytical and experimental modal analyses of a highway bridge model

  • Altunisik, Ahmet Can;Bayraktar, Alemdar;Sevim, Baris
    • Computers and Concrete
    • /
    • v.12 no.6
    • /
    • pp.803-818
    • /
    • 2013
  • In this study, analytical and experimental modal analyses of a scaled bridge model are carried out to extract the dynamic characteristics such as natural frequency, mode shapes and damping ratios. For this purpose, a scaled bridge model is constructed in laboratory conditions. Three dimensional finite element model of the bridge is constituted and dynamic characteristics are determined, analytically. To identify the dynamic characteristics experimentally; Experimental Modal Analyses (ambient and forced vibration tests) are conducted to the bridge model. In the ambient vibration tests, natural excitations are provided and the response of the bridge model is measured. Sensitivity accelerometers are placed to collect signals from the measurements. The signals collected from the tests are processed by Operational Modal Analysis; and the dynamic characteristics of the bridge model are estimated using Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods. In the forced vibration tests, excitation of the bridge model is induced by an impact hammer and the frequency response functions are obtained. From the finite element analyses, a total of 8 natural frequencies are attained between 28.33 and 313.5 Hz. Considering the first eight mode shapes, these modes can be classified into longitudinal, transverse and vertical modes. It is seen that the dynamic characteristics obtained from the ambient and forced vibration tests are close to each other. It can be stated that the both of Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods are very useful to identify the dynamic characteristics of the bridge model. The first eight natural frequencies are obtained from experimental measurements between 25.00-299.5 Hz. In addition, the dynamic characteristics obtained from the finite element analyses have a good correlation with experimental frequencies and mode shapes. The MAC values obtained between 90-100% and 80-100% using experimental results and experimental-analytical results, respectively.

Current Unbalance Improved Half-bridge LLC Resonant Converter using the Two Transformers (두 개의 변압기를 이용한 전류불균형 개선 하프브리지 LLC 공진형 컨버터)

  • Yoo, Doo-Hee;Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.497-507
    • /
    • 2010
  • This paper presents current unbalance improved half-bridge LLC resonant converter using the two transformers with different leakage inductances. The proposed converter resonates with the leakage inductance and magnetizing inductance of the transformer and the resonant capacitance. The converter operates in a wide load range and satisfies the zero voltage switching even under the light load. The series-parallel connected two transformers act as the transformers or the resonant inductances according to the operational modes, and the separate output filter inductance in the transformer secondary is not needed using the leakage inductance. The current unbalance of the secondary diode rectifier is improved using the different leakage inductances of the two transformers and the asymmetrical pulse-width modulation (PWM). In this paper, the operational principle of the converter is explained by the modes, and the design example for the prototype is also shown. To validate the performance of the converter, the prototype is implemented as the designed circuit parameters and the good performance of the proposed converter is shown through the experimental results