• 제목/요약/키워드: Operational Temperature

검색결과 582건 처리시간 0.031초

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

성형조건과 수지의 종류에 따른 사출 성형품의 성형 수축 (Shrinkage in Injection molded Part for Operational Conditions and Resins)

  • 모정혁;김현진;류민영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.363-370
    • /
    • 2003
  • Shrinkage of injection molded parts is different form operational conditions of injection molding such as injection temperature, injection pressure and mold temperature, and mold design such as gate size. It is also various for different resins which have crystalline structure or not. In this study part shrinkage was investigated for various operational condition and resins; PBT for crystalline polymer, and PC and PMMA for amorphous polymer was used in experiment. Crystalline polymer shows higher part shrinkage by about three times than amorphous polymer. Part shrinkage increased as injection temperature and mold temperature increased and injection pressure decreased. Part shrinkage decreased as gate size increased since the pressure delivery is mush easier for large gate size. Part shrinkage according to the gate location was that the position in the part with close to the gate showed large shrinkage and this phenomenon might be occurred by residual stress.

  • PDF

센서 신호 처리를 위한 온도 보상 기능을 가진 2단 CMOS 연산 증폭기 (A 2-stage CMOS operational amplifier with temperature compensation function for sensor signal processing)

  • 하상민;서상호;신장규
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.280-285
    • /
    • 2009
  • In this paper, we designed a 2-stage CMOS operational amplifier with temperature compensation function using 2-poly 4-metal 0.35 $\mu$m standard CMOS technology. Using two bias circuits, the positive temperature coefficient(PTC) and the negative temperature coefficient(NTC) of the bias circuit are canceled out each other. When reference current circuit is simulated that it has a temperature coefficient of -150 ppm/$^{\circ}C$ with a temperature change from 0 $^{\circ}C$ to 120 $^{\circ}C$. Also the proposed circuit has a temperature coefficient of -0.011 dB/$^{\circ}C$ of DC open loop gain with the same temperature range.

온도규격 설정을 위한 한반도 및 주변권역 온도분석 연구 (A Temperature Analysis Study of Korea and its Neighbor Regions for Temperature Specification)

  • 김인수;강치우
    • 한국군사과학기술학회지
    • /
    • 제18권1호
    • /
    • pp.55-65
    • /
    • 2015
  • This paper describes the results of a temperature analysis of Korea and its neighbor regions for temperature specification of weapon systems to be deployed in Korea, and introduces the concept of a standard deviation frequency of occurrence which represents a frequency of yearly occurrence. On the basis of this analysis, reasonable operational temperatures for the Korea weapon systems are recommended, and the regional frequency of yearly occurrence of temperatures worse than recommended operational temperatures in each country regions are presented.

현업 기후예측시스템에서의 지면초기화 적용에 따른 예측 민감도 분석 (Application of Land Initialization and its Impact in KMA's Operational Climate Prediction System)

  • 임소민;현유경;지희숙;이조한
    • 대기
    • /
    • 제31권3호
    • /
    • pp.327-340
    • /
    • 2021
  • In this study, the impact of soil moisture initialization in GloSea5, the operational climate prediction system of the Korea Meteorological Administration (KMA), has been investigated for the period of 1991~2010. To overcome the large uncertainties of soil moisture in the reanalysis, JRA55 reanalysis and CMAP precipitation were used as input of JULES land surface model and produced soil moisture initial field. Overall, both mean and variability were initialized drier and smaller than before, and the changes in the surface temperature and pressure in boreal summer and winter were examined using ensemble prediction data. More realistic soil moisture had a significant impact, especially within 2 months. The decreasing (increasing) soil moisture induced increases (decreases) of temperature and decreases (increases) of sea-level pressure in boreal summer and its impacts were maintained for 3~4 months. During the boreal winter, its effect was less significant than in boreal summer and maintained for about 2 months. On the other hand, the changes of surface temperature were more noticeable in the southern hemisphere, and the relationship between temperature and soil moisture was the same as the boreal summer. It has been noted that the impact of land initialization is more evident in the summer hemispheres, and this is expected to improve the simulation of summer heat wave in the KMA's operational climate prediction system.

현 기후예측시스템에서의 기온과 강수 계절 확률 예측 신뢰도 평가 (Reliability Assessment of Temperature and Precipitation Seasonal Probability in Current Climate Prediction Systems)

  • 현유경;박진경;이조한;임소민;허솔잎;함현준;이상민;지희숙;김윤재
    • 대기
    • /
    • 제30권2호
    • /
    • pp.141-154
    • /
    • 2020
  • Seasonal forecast is growing in demand, as it provides valuable information for decision making and potential to reduce impact on weather events. This study examines how operational climate prediction systems can be reliable, producing the probability forecast in seasonal scale. A reliability diagram was used, which is a tool for the reliability by comparing probabilities with the corresponding observed frequency. It is proposed for a method grading scales of 1-5 based on the reliability diagram to quantify the reliability. Probabilities are derived from ensemble members using hindcast data. The analysis is focused on skill for 2 m temperature and precipitation from climate prediction systems in KMA, UKMO, and ECMWF, NCEP and JMA. Five categorizations are found depending on variables, seasons and regions. The probability forecast for 2 m temperature can be relied on while that for precipitation is reliable only in few regions. The probabilistic skill in KMA and UKMO is comparable with ECMWF, and the reliabilities tend to increase as the ensemble size and hindcast period increasing.

사출성형의 공정변수에 따른 캐비티 내의 온도와 압력의 변화 (Variations of Temperature and Pressure in the Cavity for Operational Conditions of Injection Molding)

  • 김수웅;박현철;류민영;진영준;김도
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.70-74
    • /
    • 2004
  • Pressure and temperature in the cavity of injection molding have been investigated. Special injection mold was designed to install pressure and temperature sensors. The sensors were supplied by KISTLER and the pressure and temperature were measured for various operational conditions, such as injection pressure, holding pressure, cooling time, mold temperature, and injection temperature. As injection pressure increased cavity pressure and temperature increase. There were no big differences in temperatures according to the holding pressures. As mold temperature increased pressure and temperature in the cavity increase. The flowability of resin increases as mold temperature increases subsequently the pressure in the cavity increases since the pressure loss is less in the low viscous medium than high ciscous medium. The cavity temperature highly depends upon mold temperature.

  • PDF

기상청 현업 모형(UM)과 1차원 난류모형(PAFOG)의 접합시스템 개발 및 검증 (Development and Validation of the Coupled System of Unified Model (UM) and PArameterized FOG (PAFOG))

  • 김원흥;염성수
    • 대기
    • /
    • 제25권1호
    • /
    • pp.149-154
    • /
    • 2015
  • As an attempt to improve fog predictability at Incheon International Airport (IIA) we couple the 3D weather forecasting model currently operational in Korea Meteorological Administration (regional Unified Model, UM_RE) with a 1D turbulence model (PAFOG). The coupling is done by extracting the meteorological data from the 3D model and properly inserting them in the PAFOG model as initial conditions and external forcing. The initial conditions include surface temperature, 2 m temperature and dew point temperature, geostrophic wind at 850 hPa and vertical profiles of temperature and dew point temperature. Moisture and temperature advections are included as external forcing and updated every hr. To validate the performance of the coupled system, simulation results of the coupled system are compared to those of the 3D model alone for the 22 sea fog cases observed over the Yellow Sea. Three statistical indices, i.e., Root Mean Square Error (RMSE), linear correlation coefficient (R) and Critical Success Index (CSI), are examined, and they all indicate that the coupled system performs better than the 3D model alone. These are certainly promising results but more improvement is required before the coupled system can actually be used as an operational fog forecasting model. For the RMSE, R, and CSI values for the coupled system are still not good enough for operational fog forecast.

온도규격 설정을 위한 동아시아 온도 분석연구 (A Temperature Analysis Study of East Asia for Generation of Temperature Specification)

  • 김인수;강치우
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.11-22
    • /
    • 2002
  • In this paper, a statistical meaning that the 1% frequency value which is used as a basis for the temperature specification generation for weapon systems is similar to $3{\sigma}$ frequency value of a year is presented, and the theoretical reference for temperature specification generation is made. The new method which extracts the 1% frequency value from general weather data, not depending on long term temperature hour data, is established, and the temperature analysis result of East Asia is also presented by using this method. On the basis of these result, operational temperature for the weapon systems to be used in the area of East Asia is recommended.

다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석 (Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House)

  • 김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.