• Title/Summary/Keyword: Operational Safety & Suitability Evaluation

Search Result 5, Processing Time 0.016 seconds

A Study on the Regulatory Framework for Operational Safety & Suitability Evaluation of MASS

  • Kwanwook Chun;Seunghyeon Lim;Hyun-Jae Jo;Hyeon Kyun Lee;Geun-Tae Yim
    • Journal of Navigation and Port Research
    • /
    • v.48 no.5
    • /
    • pp.376-383
    • /
    • 2024
  • The 'Korea Autonomous Surface Ship' project has been underway from 2020 to 2025, featuring active demonstrations of key maritime technologies. In response, the 'Act on the Development and Commercialization of Autonomous Ships' will take effect on January 3, 2025, establishing a regulatory framework to support the advancement of autonomous ships. As these developments progress, there is a growing need for operational environment information that is specifically tailored to the perception and utilization of autonomous ships, ensuring their safe and efficient operation in maritime settings. This study examines the regulatory framework related to the development of 'Operational Safety and Suitability Evaluation Technology for Autonomous Ships' and proposes potential improvements for the Operational Safety and Suitability Evaluation of Maritime Autonomous Surface Ships (MASS).

An Empirical Study on the Sprinkler Operational Characteristics and Escape Time Estimation (스프링클러 작동특성(作動特性)과 피난평가(避難評價)에 관한 실증적(實證的) 연구(硏究))

  • Jin, Bok-Kweon
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.3
    • /
    • pp.37-50
    • /
    • 2006
  • The trends in building construction these days are moving towards having better work spaces and greater suitability for the use of information technology. Therefore people can work in a more relaxed delightful and pleasant environment. Accident such as like fire could cause the mass destruction of human beings. This paper aims to evaluate the path of the spread of a fire and the suitability of fire fighting appliances for maximum egress time. General advanced phase of compartment. Aswell, we analyzed and verified the path of the flame in compartment fires. Also we conducted an analysis of the adaptation of sprinkler systems concerned with sprinkler RTI. Moreover those evaluation is made more earlier by the development and use of computer simulation program and rapid progress to apply PBFD (Performance Based Fire Design).

Evaluation of Complexation Suitability of Leisure Facilities for the Elderly in Elementary School - Focused on the Current Condition of Facilities of Elementary School - (초등학교시설의 노인여가복지시설 복합화 적합성 평가 - 초등학교 시설현황을 중심으로 -)

  • Lim, Do-Young;Song, Byung-Joon;Chu, Beom
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.6
    • /
    • pp.202-211
    • /
    • 2015
  • This study attempts to deduce the necessity and validity of complexation, and suggests complexation through complexation suitability evaluations as follows. First, the concept and current state of leisure facilities for the elderly and elementary facilities and architectural complexation were investigated through theoretical considerations. Second, the target schools for complexation of 'elementary school-leisure facility for the elderly' were selected. The aspects of facility introduction of an elementary school, teacher support facility, convenience facility for the disabled, safety and security facilities as well as school facility accessibility were investigated on the basis of the data attained from theoretical considerations. Third, the feasibility of complexation of leisure facilities for the elderly was reviewed, based on the investigated data on complexation-targeted elementary school. Regarding school building and support facilities, with a focus on leisure programs for the elderly, the availability and number of rooms, extra numbers of regular classrooms and the room condition were assessed on the basis of the analysis of operational perspective of each facility. The convenience facilities for the disabled were examined by classifying them into interventional facility in consideration of facilities for the elderly, pursuant to the provisions in the convenience promotion assurance act for the disabled, elderly and pregnant women. Safety and security facilities were evaluated in an effort to assess the safety issue of the elderly and children. The result of the evaluation of the 6 elementary schools in Seong-buk county based on the above-mentioned four measurement standards shows that they scored 107~124 points out of the total 155 points, with the average of 118.5 points. This is more than the medium score and shows the possible complexation of the elementary school facilities as the leisure facilities for the elderly, and at the same time it may lead each school to find out the elements conducive to enhancing the complexation as a result of the evaluation. Through the evaluation data, I expect that we contribute to promoting the process of the evaluation of the appropriateness of complexation and the efficient complexation.

Lifespan assessment of piezoelectric sensors under disposal condition of high-level nuclear waste repository

  • Changhee Park;Hyun-Joong Hwang;Chang-Ho Hong;Jin-Seop Kim;Gye-Chun Cho
    • Geomechanics and Engineering
    • /
    • v.38 no.5
    • /
    • pp.529-539
    • /
    • 2024
  • A high-level nuclear waste (HLW) repository is designed for the long-term disposal of high-level waste. Positioned at depths of 500-1000 meters, it offers an alternative to the insufficient storage space for spent fuels, providing a long-term solution. High-level waste emits heat and radiation, causing structural deterioration, including strength reduction and cracks. Therefore, the use of piezoelectric sensors for structural health monitoring is essential for evaluating the safety of the structure over time. Unlike other structures, the HLW repository restricts human access after the disposal of HLW, rendering sensor replacement impossible. Therefore, it is necessary to assess both the lifespan and suitability of sensors under the disposal conditions in the HLW repository. This study employed an accelerated life test (ALT) to assess the sensor's lifespan under disposal conditions. Failure modes, failure mechanisms, and operational limits were analyzed through accelerated stress test (AST). Additionally, the parameters of the Weibull life probability distribution and the Arrhenius accelerated life model were estimated through statistical methods, including the likelihood ratio test, maximum likelihood estimation, and hypothesis testing. Results confirmed that the sensor's lifespan decreases significantly with the increase in the temperature limit of the HLW repository. The findings of this study can be used for improving sensor lifespan through shielding, development of alternative sensors, or lifespan evaluation of alternative monitoring sensors.

A Study on Water Demand Forecasting Methods Applicable to Developing Country (개발도상국에 적용 가능한 물수요 예측 방법 연구)

  • Sung-Uk Kim;Kye-Won Jun;Wan-Seop Pi;Jong-Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.75-84
    • /
    • 2023
  • Many developing countries face challenges in estimating long-term discharge due to the lack of hydrological data for water supply planning, making it difficult to establish a rational water supply plan for decision-making on water distribution. The study area, the Bandung region in Indonesia, is experiencing rapid urbanization and population concentration, leading to a severe shortage of freshwater. The absence of water reservoir prediction methods has resulted in a water supply rate of approximately 20%. In this study, we aimed to propose an approach for predicting water reservoirs in developing countries by analyzing water safety and potential water supply using the MODSIM (Modified SIMYLD) network model. To assess the suitability of the MODSIM model, we applied the unit hydrograph method to calculate long-term discharge based on 19 years of discharge data (2002-2020) from the Pataruman observation station. The analysis confirmed alignment with the existing monthly optimal operation curve. The analysis of power plant capacity revealed a difference of approximately 0.30% to 0.50%, and the water intake safety at the Pataruman point showed 1.64% for Q95% flow and 0.47% for Q355 flow higher. Operational efficiency, compared to the existing reservoir optimal operation curve, was measured at around 1%, confirming the potential of using the MODSIM network model for water supply evaluation and the need for water supply facilities.