• Title/Summary/Keyword: Operational Mode

Search Result 439, Processing Time 0.032 seconds

Establishing RAM Requirement based on BCS model for Weapon Systems (BCS 모델을 이용한 무기체계 RAM 요구조건 수립)

  • Eo, Seong-Phil;Kim, Sung-Jin;Kim, Dae-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.67-76
    • /
    • 2010
  • RAM(Reliability, Availability, Maintainability) characteristics of weapon system is a part of Required Operational Capability, must be reasonable and achievable. In this study, we studied the criteria, important factors to establish RAM requirement and reviewed the current process. Then we propose the new process and method to establish the reasonable and achievable RAM requirement by BCS(Baseline Comparison System) model.

Demand and Schedule Operation Mode for Personal Rapid Transit

  • Hwang, Jong-Gyu;Kim, Baek-Hyun;Kang, Seok-Won;Jeong, Rak Gyo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.356-360
    • /
    • 2013
  • The PRT (Personal Rapid Transit) system is a new transportation system in accordance with the requirements of the passengers. Although this PRT system was proposed a long time ago, it did not hold the limelight due to the several limitations in technology. However, the research and development has been active again recently thanks to the development in technology and the review on its applicability as the means of transportation linking to the urban transit system. Although most of these recent studies in relation to the PRT are focused on the hardware such as PRT vehicles or track structures, etc., the operational aspect of it is more important than that of any other means of public transportation. Therefore, among studies on operational aspect of this PRT system, this paper shows the result of study on technology in relation to the movement of vehicle to the station where it was called by the passenger through interface of the wayside control center with the vehicle control system in case where the passenger calls a vehicle at the station.

Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests

  • Sevim, Baris;Altunisik, Ahmet Can;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • v.10 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The aim of the study is to determine the modal parameters of a prototype damaged arch dam by operational modal analysis (OMA) method for some damage scenarios. For this purpose, a prototype arch dam-reservoir-foundation model is constructed under laboratory conditions. Ambient vibration tests on the arch dam model are performed to identify the modal parameters such as natural frequency, mode shape and damping ratio. The tests are conducted for four test-case scenarios: an undamaged dam with empty reservoir, two different damaged dams with empty reservoirs, and a damaged dam with full reservoir. Loading simulating random impact effects is applied on the dam to crack. Cracks and fractures occurred at the middle of the upper part of the dams and distributed through the abutments. Sensitivity accelerometers are placed on the dams' crests to collect signals for measurements. Operational modal analysis software processes the signals collected from the ambient vibration tests, and enhanced frequency domain decomposition and stochastic subspace identification techniques are used to estimate modal parameters of the dams. The modal parameters are obtained to establish a basis for comparison of the results of two techniques for each damage case. Results show that approximately 35-40% difference exists between the natural frequencies obtained from Case 1 and Case 4. The natural frequencies of the dam considerably decrease with increasing cracks. However, observation shows that the filled reservoir slightly affected modal parameters of the dam after severe cracking. The mode shapes obtained are symmetrical and anti-symmetrical. Apparently, mode shapes in Case 1 represent the probable responses of arch dams more accurately. Also, damping ratio show an increase when cracking increases.

Investigation of mode identifiability of a cable-stayed bridge: comparison from ambient vibration responses and from typhoon-induced dynamic responses

  • Ni, Y.Q.;Wang, Y.W.;Xia, Y.X.
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.447-468
    • /
    • 2015
  • Modal identification of civil engineering structures based on ambient vibration measurement has been widely investigated in the past decades, and a variety of output-only operational modal identification methods have been proposed. However, vibration modes, even fundamental low-order modes, are not always identifiable for large-scale structures under ambient vibration excitation. The identifiability of vibration modes, deficiency in modal identification, and criteria to evaluate robustness of the identified modes when applying output-only modal identification techniques to ambient vibration responses were scarcely studied. In this study, the mode identifiability of the cable-stayed Ting Kau Bridge using ambient vibration measurements and the influence of the excitation intensity on the deficiency and robustness in modal identification are investigated with long-term monitoring data of acceleration responses acquired from the bridge under different excitation conditions. It is observed that a few low-order modes, including the second global mode, are not identifiable by common output-only modal identification algorithms under normal ambient excitations due to traffic and monsoon. The deficient modes can be activated and identified only when the excitation intensity attains a certain level (e.g., during strong typhoons). The reason why a few low-order modes fail to be reliably identified under weak ambient vibration excitations and the relation between the mode identifiability and the excitation intensity are addressed through comparing the frequency-domain responses under normal ambient vibration excitations and under typhoon excitations and analyzing the wind speeds corresponding to different response data samples used in modal identification. The threshold value of wind speed (generalized excitation intensity) that makes the deficient modes identifiable is determined.

Ambient vibration testing of Berta Highway Bridge with post-tension tendons

  • Kudu, Fatma Nur;Bayraktar, Alemdar;Bakir, Pelin Gundes;Turker, Temel;Altunisik, Ahmet Can
    • Steel and Composite Structures
    • /
    • v.16 no.1
    • /
    • pp.21-44
    • /
    • 2014
  • The aim of this study is to determine the dynamic characteristics of long reinforced concrete highway bridges with post-tension tendons using analytical and experimental methods. It is known that the deck length and height of bridges are affected the dynamic characteristics considerably. For this purpose, Berta Bridge constructed in deep valley, in Artvin, Turkey, is selected as an application. The Bridge has two piers with height of 109.245 m and 85.193 m, and the total length of deck is 340.0 m. Analytical and experimental studies are carried out on Berta Bridge which was built in accordance with the balanced cantilever method. Finite Element Method (FEM) and Operational Modal Analysis (OMA) which considers ambient vibration data were used in analytical and experimental studies, respectively. Finite element model of the bridge is created by using SAP2000 program to obtain analytical dynamic characteristics such as the natural frequencies and mode shapes. The ambient vibration tests are performed using Operational Modal Analysis under wind and human loads. Enhanced Frequency Domain Decomposition (EFDD) and Stochastic Subspace Identification (SSI) methods are used to obtain experimental dynamic characteristics like natural frequencies, mode shapes and damping ratios. At the end of the study, analytical and experimental dynamic characteristic are compared with each other and the finite element model of the bridge was updated considering the material properties and boundary conditions. It is emphasized that Operational Modal Analysis method based on the ambient vibrations can be used safely to determine the dynamic characteristics, to update the finite element models, and to monitor the structural health of long reinforced concrete highway bridges constructed with the balanced cantilever method.

Primary Students Concept on the Movement of the Moon (달의 운동에 관한 초등학생들의 개념 조사)

  • 최숙희
    • Journal of Korean Elementary Science Education
    • /
    • v.19 no.1
    • /
    • pp.41-56
    • /
    • 2000
  • The purpose of this study was to investigate the change of elementary school students' conception on the movement of the moon, after teaching a lesson about the lunar phase which focused on concrete activities. The 396 subjects in this study consisted of intact groups of second, third, fourth, fifth, and sixth grade students. Pre-test and post-test instrument concerning on the conception in the movement of the moon were developed after reviewing the related literature and curriculum. Prevailing conceptions were identified by frequency of each conception. Then, the pattern of change and consistency of each conception were analyzed in comparison pre-test with post-test. To figure out the effect of teaching, the GEFT and the GALT instrument were administered to analyze it by gender, cognition mode and level. SPSS/WIN programs were used to process the data. The result showed that teaching 'movement of the moon' was the most effective in fourth grade. The effect of teaching 'changes in shape of the moon' was effective regardless of their sexes. Teaching 'changes in shapes of the moon' was more effective for the students whose cognitive modes were field-independent, than those filed-dependent. But the improvement by the teaching was not significantly different. The pre-score by cognitive level was significantly high in the order of the formal operational, transitional stage and the concrete operational stage. But the improvement of conception after teaching was high in the order of the concrete operational, transitional stage and the formal operational stage. That is to say, teaching was more effective as the cognitive level lowered.

  • PDF

Steady State Operational Characteristic Analysis of the Propulsion System for the Canard Rotor Wing UAV in three different Flight Modes (비행 모드에 따른 CRW UAV 추진시스템의 정상상태 운전특성 해석)

  • 공창덕;강명철;기자영;박종하;양수석;전용민
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.215-218
    • /
    • 2003
  • In this study, a performance model of the Smart UAV propulsion system with ducts, tip jets and variable main nozzle, which has flight capability of the rotary wing mode for the take-off/landing and low speed forward flight as well as the fixed wing mode for high speed forward flight, has been newly developed. With the proposed model, steady-state performance analysis was performed at various flight modes and conditions, such as rotary wing mode, fixed wing mode, compound wing, mode altitude and flight speed.

  • PDF

A novel 622Mbps burst mode CDR circuit using two-loop switching

  • Han, Pyung-Su;Lee, Cheon-Oh;Park, Woo-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.4
    • /
    • pp.188-193
    • /
    • 2003
  • This paper describes a novel burst-mode clock and data recovery (CDR) circuit which can be used for 622Mbps burst mode applications. The CDR circuit is basically a phase locked loop (PLL) having two phase detectors (PDs), one for the reference clock and the other for the NRZ data, whose operations are controlled by an external control signal. This CDR was fabricated in a 1-poly 5-metal $0.25{\;}\mu\textrm{m}$ CMOS technology. Jitter generation, burst/continuous mode data receptions were tested. Operational frequency range is 320Mhz~720Mhz and BER is less than 1e-12 for PRBS31 at 622Mhz. For the same data sequence, the extracted clock jitter is less than 8ps rms. Power consumption of 100mW was measured without I/O circuits.

Safety Assessment of LNG Transferring System subjected to gas leakage using FMEA and FTA

  • Lee, Jang-Hyun;Hwang, Seyun;Kim, Sungchan
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.3 no.3
    • /
    • pp.125-135
    • /
    • 2017
  • The paper considers the practical application of the FMEA(Failure Mode and Effect Analysis) method to assess the operational reliability of the LNG(Liquefied Natural Gas) transfer system, which is a potential problem for the connection between the LNG FPSO and LNG carrier. Hazard Identification (HAZID) and Hazard operability (HAZOP) are applied to identify the risks and hazards during the operation of LNG transfer system. The approach is performed for the FMEA to assess the reliability based on the detection of defects typical to LNG transfer system. FTA and FMEA associated with a probabilistic risk database to the operation scenarios are applied to assess the risk. After providing an outline of the safety assessment procedure for the operational problems of system, safety assessment example is presented, providing details on the fault tree of operational accident, safety assessment, and risk measures.