• 제목/요약/키워드: Operational Load

검색결과 433건 처리시간 0.027초

소용량 고온초전도 동기모터의 제작 및 특성 실험에 관한 연구 (The Design, Manufacture and Characteristic Experiment of a Small-Scaled High-Tc Superconducting Synchronous Motor)

  • 송명곤;윤용수;홍계원;장인배;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.241-243
    • /
    • 1999
  • This paper describes a series of experiments investigating the operational characteristics of high-Tc superconducting synchronous motor of five to six hundred watts capacity. In this experiment, ac 220V stator phase voltage and DC 4A excitation current are used, and the synchronous speed runs at 1800rpm. Hall Sensors are installed on the pole face and at the side of the Ag/Bi-2223 high-Tc superconducting tape in order to analyze the effect of the time-varying magnetic field on the motor performance when the load changes its value. The experimental observations are compared with the theoretical predictions.

  • PDF

정수 측정 시험에 의한 고효율 유도 전동기의 손실 특성 비교 (Comparison of Loss Characteristics of High-Efficiency Induction Motor by Parameter Measurement Test)

  • 변한섭;김성철;양성한;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.318-320
    • /
    • 1999
  • Electric motor transforms electric power into mechanical power. It is important to increase efficiency of motor to save energy and to decrease operating cost. In this paper, some parameters and losses of high-efficiency induction motor and standard induction motor are measured by blocked-rotor test and no-load test. Operational parameters of high-efficiency induction motor that are compared with those of standard motor.

  • PDF

점착성 부유사 이동에 관한 수치모형 (A Numerical Model for Cohesive Suspended Load Movement)

  • 안수한;이상화
    • 물과 미래
    • /
    • 제23권1호
    • /
    • pp.119-127
    • /
    • 1990
  • 점착성 부유사 농도분포는 해수유동과 물질 확산에 의해서 결정되며 지배방정식으로는 2차원 수심적분된 Reynolds운동방정식, 연속방정식과 Fick의 확산법칙에 근거를 둔 대류-확산방정식이 사용되었다. 해수유동과 점성퇴적물 확산인 두개의 모형은 유한차분법을 이용하였고 유동모형은 양해법, 확산모형은 다증법을 사용하여 부유사 이동의 현상을 파악하였다. 해수유동방정식의 적용시 이송항의 포함여부에 대해서 조사하였으며 물질확산 방정식에 대해서는 한계전단응력값의 변화가 부유사농도에 영향을 주는가에 대해서 비교하였다.

  • PDF

인공습지에서의 물질순환에 관한 연구 (Cycling of Matters in the Constructed Wetland)

  • 김동억;박제철
    • 한국환경과학회지
    • /
    • 제29권3호
    • /
    • pp.299-306
    • /
    • 2020
  • This study analyzed the changes in the concentrations of the pollutants of constructed treatment wetlands which come from the discharge water of a sewage treatment plant. According to the results of budgets in constructed wetlands, the net production of the organic carbon, nitrogen and phosphorus were 368 kgC/month, 306 kgN/month and -49 kgP/month, respectively. The high particle form of pollutants are mostly removed due to settlement and absorption when passing through wetlands, but because a low processing efficiency for pollutants was shown when sewage treatment plant wastewater flows in, there is a need for a water management system that can reduce the organic matter load through monitoring. The low removal efficiency of constructed wetlands were caused by both structural and operational problems. Therefore, to enable to play a role as a reduction facility of pollutants, an appropriate design and operation manuals for constructed wetlands is urgently needed.

Parametric Study of Offshore Pipeline Wall Thickness by DNV-OS-F101, 2010

  • Choi, Han-Suk;Yu, Su-Young;Kang, Dae-Hoon;Kang, Hyo-Dong
    • 한국해양공학회지
    • /
    • 제26권2호
    • /
    • pp.1-7
    • /
    • 2012
  • DNV-OS-F101 includes the concept development, design, construction, operation,and abandonment of offshore pipeline systems. The main objective of this offshore standard (OS) is to ensure that pipeline systems are safe during the installation and operational period. The pipeline design philosophy also includes public safety and environmental protection. The mechanical wall thickness design of a pipeline shall follow the design objectives and safety philosophy. This new design code includes a very sophisticated design procedure to ensure a safe pipeline, public safety, and environmental protection. This paper presents the results of a parametric study for the wall thickness design of offshore pipelines. A design matrix was developed to cover the many design factors of pipeline integrity, public safety, and environmental protection. Sensitivity analyses of the various parameters were carried out to identify the impacts on offshore pipeline design.

Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) 개발 (Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method)

  • 정종규;한병문
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1954-1961
    • /
    • 2009
  • This paper describes the development of a three-phase line-interactive dynamic voltage restorer with hybrid detection method, which is composed of three H-bridge inverter modules and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 3kVA prototype. The developed system can compensate the input voltage sag and interruption within 2ms. The maximum allowable duration of voltage interruption is about 4 seconds. The developed system can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication devices, and automation devices, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components, and to be highly reliable in operation.

A Novel Control Strategy for a Three-Phase Rectifier with High Power Factor and Stable Output Voltage

  • Lee, Hong-Hee;Phan, Van-Tung;Sergey, Brovanov;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.203-212
    • /
    • 2007
  • In this paper, a proposed approach to improve the power factor of three-phase rectifiers and to stabilize the output voltage against load change is presented. The elements of the given control strategy are small size, low cost, high performance, and simplicity. The proposed control strategy of switches is based on a prototype of three bi-directional switched consisting of four diodes and one IGBT. A control technique and operational procedure are also developed, both theoretically and experimentally. The experimental results clearly verify the theoretical analysis from the prototype connected to grid unity.

지식기반을 이용한 특수일의 수요예측 (Load Forecasting for Special Days Using Knowledge Base)

  • 조승우;황갑주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.698-700
    • /
    • 1996
  • A knowledge based forecasting system for special days has been developed for the economic and secure operation of electric power system. If-then production rules has been adopted in this system to be used in various environmental conditions. Graphic user interfaces enables a user to access easily to the system. The simulation based on the historical data have shown that the forecasting result was improved remarkably when compared to the results from the conventional statistical methods. The forecasting results can be used for power system operational planning to improve security and economy of the power system.

  • PDF

와전류 커플링의 특성 비교 (Characteristic Comparison of Three Types of Eddy Current Coupling)

  • 장석명;조성국;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1036-1038
    • /
    • 2003
  • Electric control of eddy coupling offers many new possibilities in process control and other industrial control applications. And a form of speed control for the load is affected for a system driven by costant frequency induction motor. This paper compare speed-torque characteristic of three types of eddy-current coupling by using the analytical method. And characteristic experiment of three types of eddy current coupling is put into operation. And then, this paper will discuss operational and magnetic field characteristic of three types model.

  • PDF

H-브리지 인버터와 수퍼커패시터로 구성된 단상 DVR(Dynamic Voltage Restorer)의 개발 (Development of Single-Phase DVR(Dynamic Voltage Restorer) Composed of H-Bridge Inverter and SuperCapacitor)

  • 이동근;이두영;양승철;배병열;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.160-161
    • /
    • 2007
  • This paper describes the development of a single-phase DVR(Dynamic voltage Restorer), which is composed of H-bridge inverter and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable duration of voltage interruption is 1.5 seconds. It can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF