• 제목/요약/키워드: Operational Load

검색결과 433건 처리시간 0.024초

축열식 지열원 히트펌프 시스템의 냉방기간 실증운전 결과 및 운영비용 분석 (Empirical Results and Operational Cost Analysis of Geothermal Heat Pump System using Thermal Energy Storage in Cooling Season)

  • 김득원;이동원;허재혁;김민휘
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.167-174
    • /
    • 2018
  • The geothermal heat pump systems were installed for heating and cooling of public buildings in Jincheon Eco-friendly Energy town. The heat pump system was operated at night to save on operational costs, and the cold heat was stored in thermal energy storage (TES). In this study, the performance of geothermal heat pump systems with the TES during the summer season was analyzed, and the operational costs with and without the TES were compared. The electric chiller model was used to simulate a heat pump applied without the TES system. Electric rates of each system were measured to calculate operational costs. When the TES is used in the air conditioning system, the electric load (30.4 MWh) calculated in the daytime can move to off-peak load time, and the operational cost is reduced by 36~54%.

Operational Mode Analysis of Cooler Driver Electronics in Satellite and System Safety Margin

  • Kim, Kyudong
    • 항공우주시스템공학회지
    • /
    • 제14권6호
    • /
    • pp.79-84
    • /
    • 2020
  • Cooler driver electronics (CDE) for maintaining low temperature of the satellite payload IR sensor consists of a compressor that has a pulsation current load condition when it is operated. This pulsation current produces large voltage fluctuation, which affects both load and regulated bus stability. Thus, CDE power conditioning system consists of a primary bus, infrared power distribution unit for battery charging and protection, reverse current protection diode, and battery, which is used as a buffer. In this study, the operational mode analysis is performed by each part with equivalent impedance modeling verified through system level simulation. From this mode analysis, the safety margin for state of charge and open circuit voltage of the battery is determined for satisfying the minimum operational voltage of the CDE load.

틸팅열차의 원곡선부 주행시 안전성 평가 (Safety evaluation of tilting train on circular curve)

  • 김상수;엄기영;배재형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1703-1712
    • /
    • 2010
  • The safety of tilting train running on curved track is, in general, evaluated with a derailment coefficient calculated by the ratio of wheel load and lateral force, Particularly on curve, the wheel load and lateral force on rail may cause trackbed to be deformed, depending on their intensity, and moreover, often result in critical accident such as derailment. This study hence was intended to identify the cause of wheel load and lateral force so as to suggest the allowable wheel load reduction rate, lateral force limit and derailment coefficient, thereby quantitatively evaluating the operational safety of tilting train. This study therefore was aimed to analyze the wheel load and lateral force occurred during tilting train's operation on circular curve in such a way of comparing with traditional trains, by axle and speed, in a bid to eventually evaluate the operational safety of tilting train.

  • PDF

동작중 작용부하 분석을 위한 간접적 부하규명 (Indirect Load Identification for the Operational Load Analysis)

  • 조문선
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권6호
    • /
    • pp.501-507
    • /
    • 2003
  • 환자의 재활을 돕는 보조기 및 의지와 같은 의료기기의 기본 요건 중의 하나는 충분한 강도를 가지도록 설계해야 하는 것이다. 강도설계를 위해서는 먼저 기구에 작용하는 부하를 파악하여야 하는데, 인체에 직접 착용하거나, 인체의 운동을 돕도록 고안된 의료기구의 특성상 정하중 보다는 동하중 형태의 부하를 받는 경우가 많으며, 때때로 충격하중을 받는 경우도 있다. 이같은 형태의 부하를 직접적으로 파악하기 위해서는 구조물에 계측용 센서를 직접 설치하여야 하나, 이럴 경우 센서의 설치로 인한 구조 변경으로 인해 계의 고유 특성을 유지할 수 없는 경우가 흔히 발생하다. 따라서, 이와 같은 경우에는 작용 부하를 간접적으로 즉, 진동 등의 출력으로부터 역으로 구해내는 수 밖에는 없다. 본 논문에서는 이와 같은 동하중 형태의 부하 즉, 작동부하를 구하는 데 있어서 기존 방법인 전달률 방법의 문제점 및 한계점을 살펴보고, 다수개의 기준점을 사용하여 다입력 환경하에서도 적용이 가능한 주성분 분석을 이용한 새로운 방법을 제시하였으며, 실험을 통해 이의 타당성을 검증하였다.

온도를 고려한 지수평활에 의한 단기부하 예측 (Short-Term Load Forecasting Exponential Smoothoing in Consideration of T)

  • 고희석;이태기;김현덕;이충식
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.730-738
    • /
    • 1994
  • The major advantage of the short-term load forecasting technique using general exponential smoothing is high accuracy and operational simplicity, but it makes large forecasting error when the load changes repidly. The paper has presented new technique to improve those shortcomings, and according to forecasted the technique proved to be valid for two years. The structure of load model is time function which consists of daily-and temperature-deviation component. The average of standard percentage erro in daily forecasting for two years was 2.02%, and this forecasting technique has improved standard erro by 0.46%. As relative coefficient for daily and seasonal forecasting is 0.95 or more, this technique proved to be valid.

  • PDF

Steady-state Operational Strategies of UPFC in the KEPCO Transmission System

  • Chang, B.H.;Choo, J.B.;Xu, X.K.;Lam, B.P.
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.161-167
    • /
    • 2003
  • This paper presents a study performed to investigate the steady-state operational strategies of UPFCs in the Jeollanam-Do system in Korea. The objective of the study was to determine the UPFC operating points under normal and contingency conditions. The study consists of developing load flow models to simulate different load levels with and without UPFCs in the system, assessing the effectiveness of UPFCs by contingency analysis, and introducing optimal corrective actions for removing voltage problems caused by contingencies. The paper describes analytical tools, models and approach. It also includes analysis and discussion of the study results. The paper contributes to the area of transmission operational studies with FACTS applications.

동적 계획법을 이용한 냉방시스템 최적운전에 관한 연구 (A Study on Optimal Operation of Cooling System Using Dynamic Programing)

  • 유성연;한규현;이제묘;이일수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1061-1064
    • /
    • 2009
  • The objective of this study is to find the optimal operational planning of the hybrid cooling system, which is combined by ice storage system and the absorption chiller. The optimization technique used in this study is dynamic programming. The objective function is summed cost during a day including charge and discharge periods of ice storage system and operation time of absorption chiller. Assuming that initially ice storage tank is stored fully and the cooling load is perfectly predicted for the operational planning. This method provides the most efficient and economic combination of equipment operational planning for cooling with respect to energy consumption cost.

  • PDF

풍력발전기용 피치/요 베어링의 시험절차 개발 (Development on Test Procedure of Pitch and Yaw Bearings for Wind Turbine)

  • 남주석;한정우
    • 한국생산제조학회지
    • /
    • 제24권3호
    • /
    • pp.355-362
    • /
    • 2015
  • Test procedure for the design verification of wind turbine pitch and yaw bearings has been developed. Test items were selected to evaluate operational reliability of pitch and yaw bearings by considering loading and operational conditions, and by analyzing the design criteria of pitch and yaw bearings. The developed test items consisted of preliminary test, fatigue load test, extreme load test, low temperature environmental test and dismantling inspection after all the test were completed. Because it reflects the actual operational conditions of the pitch and yaw bearings, the developed test procedure has high reliability and can verify the basic design considerations in the international standard and guidelines.

Improved modeling of equivalent static loads on wind turbine towers

  • Gong, Kuangmin;Chen, Xinzhong
    • Wind and Structures
    • /
    • 제20권5호
    • /
    • pp.609-622
    • /
    • 2015
  • This study presents a dynamic response analysis of operational and parked wind turbines in order to gain better understanding of the roles of wind loads on turbine blades and tower in the generation of turbine response. The results show that the wind load on the tower has a negligible effect on the blade responses of both operational and parked turbines. Its effect on the tower response is also negligible for operational turbine, but is significant for parked turbine. The tower extreme responses due to the wind loads on blades and tower of parked turbine can be estimated separately and then combined for the estimation of total tower extreme response. In current wind turbine design practice, the tower extreme response due to the wind loads on blades is often represented as a static response under an equivalent static load in terms of a concentrated force and a moment at the tower top. This study presents an improved equivalent static load model with additional distributed inertial force on tower, and introduces the square-root-of-sum-square combination rule, which is shown to provide a better prediction of tower extreme response.

산업체 열병합발전시스템에서 최적운전계획 수립을 위한 진화 알고리즘을 이용한 GUI System 개발 (A Development of GUI System for Optimal Operational Scheduling on Industrial Cogeneration Systems Using Evolutionary Algorithms)

  • 정지훈;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.544-550
    • /
    • 2002
  • This paper describes a strategy of a daily optimal operational scheduling on the industrial cogeneration system. The cogeneration system selected to establish the scheduling consists of three units and several auxiliary devices which include three auxiliary boilers, t재 waste boilers and three sludge incinerators. One unit generated electrical and thermal energy using the back pressure turbine. The other two units generate the energy using the extraction condensing turbine. Three auxiliary devices operate to supply energy to the loads with three units. The cogeneration system is able to supply enough the thermal energy to the thermal load, however it can not sufficiently supply the electric energy to the electrical load. Therefore the insufficient electric energy is compensated by buying electrical energy from utility. In this paper, the evolutionary algorithms was applied to establish the optimal scheduling for the cogeneration systems. Also the GUI System was developed using established mathematics medeling and evolutionary algorithms in order that non-experts are able to establish operational scheduling. This results revel that the proposed modeling and strategy can be effectively applied to cogeneration system for paper mill.