• Title/Summary/Keyword: Operation voltage

Search Result 3,665, Processing Time 0.026 seconds

The changes in signal-averaged electrocardiogram after surgical correction of congenital heart disease (선천성 심장병의 개심술 후 신호 평준화 심전도의 변화)

  • Kim, Yeo Hyang;Choe, Hee Jung;Kim, Gun Jik;Cho, Joon Yong;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.12
    • /
    • pp.1364-1369
    • /
    • 2009
  • Purpose : To analyze abnormal ventricular activation in childhood congenital heart disease induced by postoperative changes in ventricular volume and pressure and ventricular scar formation using signal-averaged electrocardiography (SAECG). Methods : Fifty-two patients who had undergone open heart surgery (OHS) were enrolled. Patients were divided into the following 3 groups: right ventricular volume overload (atrial septal defect, group1), left ventricular volume overload (ventricular septal defect, group2), and right ventricular pressure overload (tetralogy of Fallot, group 3). The patients were monitored by standard 12-lead ECG and SAECG before and 2 months after the operation. QRS duration, QT and QTc intervals, filtered QRS (f-QRS), high frequency low amplitude potential (HFLA), and root mean square (RMS) voltage in the terminal 40 ms of SAECG were determined. Results : In the preoperative period, group1 showed significant increase in QRS (P=0.011) compared to those of the other 2 groups. In the postoperative period, group3 showed significant increase in the QTc interval (P=0.004) compared to those in the other 2 groups. SAECG parameters showed no significant differences among the groups in the pre- or postoperative period. Of the 52 patients, 12 (23%) in the preoperative period and 21 (40%) in the postoperative period had at least 1 SAECG abnormality. The prevalence of SAECG abnormalities was significantly higher in the postoperative group 2 and group 3 (preoperative: 20% versus postoperative: 28%, P<0.001, preoperative: 14% versus postoperative: 64%, P<0.001, respectively). Conclusion : Abnormal SAECG patterns may be attributed to postoperative scars, OHS itself, and/or ventricular overload.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

Neuroprotective Effect of Phenytoin and Hypothermia on a Spinal Cord Ischemic Injury Model in Rabbits (토끼의 척수 허혈 손상 모델에서 페니토인과 저체온의 신경 보호 효과의 비교)

  • Oh, Sam-Sae;Choe, Ghee-Young;Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.405-416
    • /
    • 2008
  • Background: Spinal cord ischemic injury during thoracic and thoracoabdominal aortic surgeries remains a potentially devastating outcome despite using various methods of protection. Neuronal voltage-dependent sodium channel antagonists are known to provide neuroprotection in cerebral ischemic models. This study was designed to compare the neuroprotective effects of phenytoin with those of hypothermia in a rabbit model of spinal cord ischemia. Material and Method: Spinal cord ischemia was induced in New Zealand white rabbits by means of infrarenal aortic cross clamping for 25 minutes. Four groups of 8 animals each were studied. The control group and the hypothermia group received retrograde infusion of saline only ($22^{\circ}C$, 2 mL/min); the normothermic phenytoin group and the hypothermicphenytoin group received retrograde infusion of 100 mg of phenytoin at different rectal temperatures ($39^{\circ}C$ and $37^{\circ}C$, respectively) during the ischemic period. The neurologic function was assessed at 24 and 72 hours after the operation with using the modified Tarlov criteria. The spinal cords were harvested after the final neurologic examination for histopathological examination to objectively quantify the amount of neuronal damage. Result: No major adverse effects were observed with the retrograde phenytoin infusion during the aortic ischemic period. All the control rabbits became severely paraplegic, Both the phenytoin group and the hypothermia group had a better neurological status than did the control group (p < 0.05). The typical morphological changes that are characteristic of neuronal necrosis in the gray matter of the control animals were demonstrated by means of the histopathological examination, whereas phenytoin or hypothermia prevented or attenuated these necrotic phenomena (p < 0.05). The number of motor neuron cells positive for TUNEL staining was significantly reduced, to a similar extent, in the rabbits treated with phenytoin or hypothermia. Phenytoin and hypothermia had some additive neuroprotective effect, but there was no statistical significance between the two on the neurological and histopathological analysis. Conclusion: The neurological and histopathological analysis consistently demonstrated that both phenytoin and hypothermia may afford significant spinal cord protection to a similar extent during spinal cord ischemia in rabbits, although no significant additive effects were noticed.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.