• Title/Summary/Keyword: Operation mode transition

검색결과 63건 처리시간 0.023초

600kW급 용융탄산염 연료전지 발전시스템용 EBOP 제어시스템 (Control System of 600kW EBOP for Molten Carbonate Fuel Cell Generation System)

  • 황태식;정우택;양병훈;김광섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.18-20
    • /
    • 2008
  • An electrical balance of plant(EBOP) of a 600kW molten carbonate fuelcell (MCFC) has to transit from grid-connected(GC) mode to grid-independent(GI) mode when a grid is in a fault conditions. A minimum transition time is limited by four cycle for a 600kW MCFC to ride through a grid fault. In this paper, we propose a control algorithm of a 600kW EBOP for a MCFC system. The EBOP has three operation modes, i.e., GC mode, GI mode, and grid-synchronized(GS) mode. The EBOP controls output currents in a GC mode and regulates output voltages in GI or GS mode. GS mode is defined as an interface between GC mode and GI mode to make a mode transition smooth, i.e., limitation of inrush currents, regulation of output voltages within ANSI standard. Simulations and experiments carried out to verify the effectiveness of the proposed control algorithm.

  • PDF

The Characteristics of Magnetic Oscillations in L-H Transition and Disruption in JFT-2M Tokamak

  • Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Sung-Kyu
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.432-437
    • /
    • 1996
  • The observed characteristics of magnetic oscillations in L-H transition and disruption are described. Two kinds of MHD magnetic probes are used in order to cover broadband frequency range from 1.3 kHz to 300 kHz in the H-mode. Depending on the probe's position and frequency, different characteristics are observed. Precursor like oscillation in L-H transition, and the difference between sawtooth and ELM are discussed. All disruptions during the current rising phase are related with m=2 or m=3 mode. Different disruption characteristics for different operation conditions could be found in the MHD probes.

  • PDF

터보펌프-가스발생기 연계시험의 모드 변환 중간 작동점 분석 (Analysis for Operation Point Change in Mode Transition at the Turbopump-Gas Generator Coupled Test)

  • 남창호;김승한;박순영;김철웅
    • 한국추진공학회지
    • /
    • 제13권1호
    • /
    • pp.43-50
    • /
    • 2009
  • 터보펌프-가스발생기 연계시험에서 작동점 변경을 위해 거치는 중간 작동점의 특성을 시스템 모사 프로그램으로 검토하였다. 중간 작동점에서 펌프 토출압, 가스발생기 혼합비, 가스발생기 온도, 가스발생기 압력 등의 변수를 안전한 시험기 운용을 고려하여 검토하였다. 터보펌프-가스발생기 연계시험기와 엔진시스템을 비교한 결과 중간 작동점이 차이는 작지만 서로 다르고 이는 엔진 시스템에서 연소기 유량에 따른 연소압 변화가 발생하기 때문이다. 연소기 배관의 밸브 변경을 우선할 때 중간 작동점이 보다 안전한 영역에 위치한다.

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

마이크로그리드에서 에너지 저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전 제어기법 (Parallel Operation Control Method of Grid-connected Inverters with Seamless Transfer for Energy Storage System in Microgrid)

  • 박성열;김주하;정아진;최세완
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.200-206
    • /
    • 2016
  • In the microgrid, inverters for energy storage system are generally constructed in a parallel structure because of capacity expandability, convenience of system maintenance, and reliability improvement. Parallel inverters are required to provide stable voltage to the critical load in PCC and to accurately share the current between each inverter. Furthermore, when islanding occurs, the inverters should change its operating mode from grid-connected mode to stand-alone mode. However, during clearing time and control mode change, the conventional control method has a negative impact on the critical load, that is, severe fluctuating voltage. In this study, a parallel operation control method is proposed. This method provides seamless mode transfer for the entire transition period, including clearing time and control mode change, and has accurate current sharing between each inverter. The proposed control method is validated through simulation and experiment.

인공위성용 전력시스템 시뮬레이텨 개발 (A development of simulator for satellite power system)

  • 김영태;김희준
    • 전자공학회논문지B
    • /
    • 제33B권3호
    • /
    • pp.193-201
    • /
    • 1996
  • The space power system for communication satellite which employs the direct energy transfer (DET) method consists of solar array, battry, shunt regulator, charger/discharger and power control unit (PCU). In this paper, the development of the DET power system charger/discharger unit and a microprocessor based PCU is developed for simplicity and flexiblity in the modificatin of control algorithm. A 28V bus voltage, 400W power rting power simulator is built and tested to verify the operation of the simulator at each mode and the stability of mode transition is analyzed.

  • PDF

매입형 영구자석 동기기 센서리스 구동부의 개선된 절환 기법 (Improved Transition Method for Sensorless Operation of Interior Permanent Magnet Synchronous Motor Drives)

  • 한동엽;윤재승;조용수;이교범
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1362-1368
    • /
    • 2016
  • This paper proposes the improved transition scheme for a sensorless drive of an interior permanent magnet synchronous motor (IPMSM). In order to operate the IPMSM, the current controller can be used until 300 rpm for the initial operation. After that, the control method of IPMSM is changed to the speed controller for the sensorless control method. At that point, the rotor speed overshoot is generated due to the rapid change of the current reference for the speed controller. The proposed algorithm is able to reduce the overshoot of a rotor speed by compensating the estimated feedforward value to the speed controller. The feedforward value of the current reference is estimated by using a coordinate transformation and is approximated to the current reference after the transition of the control mode. The effectiveness of the proposed scheme is verified by experiments using an IPMSM drive system.

A Bidirectional Single-Stage DC/AC Converter for Grid Connected Energy Storage Systems

  • Chen, Jianliang;Liao, Xiaozhong;Sha, Deshang
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1026-1034
    • /
    • 2015
  • In this paper, a unified control strategy using the current space vector modulation (CSVM) technique is proposed and applied to a bidirectional three-phase DC/AC converter. The operation of the converter changes with the direction of the power flow. In the charging mode, it works as a buck type rectifier; and during the discharging mode, it operates as a boost type inverter, which makes it suitable as an interface between high voltage AC grids and low voltage energy storage devices. This topology has the following advantages: high conversion efficiency, high power factor at the grid side, tight control of the charging current and fast transition between the charging and discharging modes. The operating principle of the mode analysis, the gate signal generation, the general control strategy and the transition from a constant current (CC) to a constant voltage (CV) in the charging mode are discussed. The proposed control strategy has been validated by simulations and experimental results obtained with a 1kW laboratory prototype using supercapacitors as an energy storage device.

단상 SRM의 고속 구동 제어에 관한 연구 (The High-speed Operation of Single Phase Switched Reluctance Motor)

  • 안준선;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권10호
    • /
    • pp.470-476
    • /
    • 2005
  • In this paper PU control scheme is presented. The proposed scheme has following features. The one is oft-starting method which is used for preventing to flow large current in motor phase winding when motor starts. The ther is the selection of the level of the over current. The first feature is implemented by increasing the PWM duty lowly, the second feature is implemented by limiting the magnitude of the phase current level by which the over heat f motor by copper losses and magnetic saturation decreases. By the analysis using FEM considering load condition, the peed of mode transition from PW to single pulse control is selected and confirmed by simulation that there is no ver current occurs during the mode transition. For the verification of proposed scheme, the simulation using MATLAB Simulink with considering non-linearity of inductance profile from FEM analysis is performed and the experiment with SRM drive system which has the DSP controller and single Phase SRM are peformed.

짧은 천이길이를 갖는 Ku-대역 감소단축도파관 대 마이크로스트립 모드 변환기 (A Ku-Band Reduced Height Waveguide to Microstrip Mode Converter with a Short Transition Length)

  • 오현석;염경환
    • 한국전자파학회논문지
    • /
    • 제19권12호
    • /
    • pp.1435-1444
    • /
    • 2008
  • 본 논문에서는 짧은 천이길이를 갖는 감소단축도파관(redured-height waveguide) 대 마이크로스트립 모드 변환기(mode converter)를 설계하였다. 모드 변환기는 E-평면 프로브를 이용한 모드 변환기와 변형된 임피던스 변환기로 구성되어진다. E-평면 프로브를 이용한 모드 변환기는 50 ohm 릿지(ridge) 도파관의 릿지 상단에 단락된 프로브를 이용하여 설계하였다. 이 모드 변환기에 이용된 50 ohm 릿지 도파관과 감소단축도파관을 연결하기 위해 변형된 임피던스 변환기를 설계하였다. 이와 같이 구성된 전체 모드 변환기의 대역을 넓히기 위해, 두 구조의 결합도를 조정하였다. 저손실 및 Ku-대역 전체에서 동작하도록 구조를 최적화한 후 모드 변환기를 제작하였다 제작된 2개의 모드 변환기를 직접 연결(thru)한 S-파라미터와 모드 변환기 사이에 라인(line) 도파관을 삽입한 후 S-파라미터를 측정하였다. 측정된 2개의 S-파라미터를 이용하여 단일 모드 변환기의 성능을 추출하였다. 이렇게 추출된 모드 변환기의 성능은 커텍터 손실을 포함하고 있어, 커백터 손실을 측정하여 보상하였다. 모드변환기는 직각구조로 7.2 mm의 천이길이를 가지며, 중심 주파수에서 0.12 dB 삽입 손실과 Ku 전대역에서 10dB 이상의 반사 손실을 갖는 우수한 특성을 보였다.