• 제목/요약/키워드: Operation mode

검색결과 2,499건 처리시간 0.023초

Performance Optimization of High Specific Speed Pump-Turbines by Means of Numerical Flow Simulation (CFD) and Model Testing

  • Kerschberger, Peter;Gehrer, Arno
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.352-359
    • /
    • 2010
  • In recent years, the market has shown increasing interest in pump-turbines. The prompt availability of pumped storage plants and the benefits to the power system achieved by peak lopping, providing reserve capacity, and rapid response in frequency control are providing a growing advantage. In this context, there is a need to develop pumpturbines that can reliably withstand dynamic operation modes, fast changes of discharge rate by adjusting the variable diffuser vanes, as well as fast changes from pumping to turbine operation. In the first part of the present study, various flow patterns linked to operation of a pump-turbine system are discussed. In this context, pump and turbine modes are presented separately and different load cases are shown in each operating mode. In order to create modern, competitive pump-turbine designs, this study further explains what design challenges should be considered in defining the geometry of a pump-turbine impeller. The second part of the paper describes an innovative, staggered approach to impeller development, applied to a low head pump-turbine project. The first level of the process consists of optimization strategies based on evolutionary algorithms together with 3D in-viscid flow analysis. In the next stage, the hydraulic behavior of both pump mode and turbine mode is evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Finally, the progress in hydraulic design is demonstrated by model test results that show a significant improvement in hydraulic performance compared to an existing reference design.

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

선박 자동접안을 위한 순수 횡 이동 모델링 및 제어기 설계 (Modeling and controller design of crabbing motion for auto-berthing)

  • 박종용;김낙완
    • 한국해양공학회지
    • /
    • 제27권6호
    • /
    • pp.56-64
    • /
    • 2013
  • Crabbing motion is the pure sway motion of a ship without surge velocity. Thus, it can be applied to a berthing operation. Crabbing motion is induced by a peculiar operation method called the push-pull mode. The push-pull mode is induced by using a combination of the main propeller and side thruster. Two propellers generating the same amounts of thrust and rotating in opposite directions produce some yawing moment on a vessel but do not induce longitudinal motion. With the additional operation of side thrusters, the push-pull mode is used to induce a large amount of lateral force. In this paper, three-degree-of-freedom equations of motion such as for the surge, sway, and yaw are constructed for the crabbing motion. Based on these equations of motion, a feedback linearization control method is applied to auto-berthing control for a twin-screw ship with side thrusters. The controller can deal with the nonlinearity of a system, which is present in the berthing maneuver of a twin screw ship. A simulation of the auto-berthing of a ship is performed to validate the performance of the designed controller.

Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

  • Hedayat, Afshin
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.953-967
    • /
    • 2017
  • In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal-hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

Application of a Dynamic Positioning System to a Maritime Autonomous Surface Ship (MASS)

  • Kim, Jeong-Min;Park, Hye Ri
    • 한국항해항만학회지
    • /
    • 제46권5호
    • /
    • pp.435-440
    • /
    • 2022
  • The development and introduction of a Maritime Autonomous Surface Ship (MASS) are some of the most important changes leading to the fourth industrial era in the maritime area. The term 'MASS' refers to a ship operating independently, without human intervention, to reduce maritime accidents caused by human errors. Recent UK findings MASS also noted that particularly the dynamic positioning system will be considered to apply as newly function to a MASS. The DP system, a ship system developed decades ago and used for specific purposes like offshore operations, provides various functions to facilitate the accurate movements of the vessel, and operators can make decisions within the DP system, in addition to the ordinary ship system. In this paper, it would like to present the connection and application method with the main technical elements of the DP system in connection with the main technology of the DP system to achieve the safe operation of a MASS. In particular, among various position reference systems, the capability plot function of DP system, and the "follow target" mode in the operation mode are attractive functions that can contribute to the safe operation of autonomous ships.

선형방식과 스위칭 방식의 레귤레이터를 함께 구동하기 위한 Mode Selector (A Mode Selector for Operation with Linear and Switching Regulator)

  • 조한희;박경현;정준모;구용서
    • 전기전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.260-264
    • /
    • 2015
  • 본 논문에서는 부하전류를 감지하여 스위칭 방식과 선형 방식의 레귤레이터를 동작하기 위한 mode selector를 제안한다. 제안된 mode selector는 선형 방식과 스위칭 방식으로의 모드 전환이 가능하며, 경부하 조건에서 낮은 효율을 갖는 스위칭 방식의 레귤레이터의 단점을 보완하고자 제안되었다. 경부하 조건에서는 선형 방식의 레귤레이터로 mode를 전환함으로써 경부하 상태에서도 높은 효율을 제공할 수 있다. 설계한 mode selector는 동부 하이텍의 $0.18{\mu}m$ CMOS 공정을 이용하였다.

Design and Analysis of Current Mode Low Temperature Polysilicon TFT Inverter/Buffer

  • Lee, Joon-Chang;Jeong, Ju-Young
    • Journal of Information Display
    • /
    • 제6권4호
    • /
    • pp.11-15
    • /
    • 2005
  • We propose a current mode logic circuit design method for LTPS TFT for enhancing circuit operating speed. Current mode inverter/buffers with passive resistive load had been designed and fabricated. Measurement results indicated that the smaller logic swing of the current mode allowed significantly faster operation than the static CMOS. In order to reduce the chip size, both all pTFT and all nTFT active load current mode inverter/buffer had been designed and analyzed by HSPICE simulation. Even though the active load current mode circuits were inferior to the passive load circuits, it was superior to static CMOS gates.

직류형 마이크로그리드의 전운전영역을 고려한 협조제어 (The Coordination Control of DC Microgrid on the Whole Operation Range)

  • 최대희;주수진;민용
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.864-871
    • /
    • 2015
  • Recently, one of the main research on the power distribution system is the microgrid. The microgrid is a combination of power sources and loads, which is controllable and has separable connection. The main objective of microgrid is the deployment of the renewable clean energy and the enhancement of load-side reliability. The modern power sources and loads have DC I/O interfaces, which is the major advantage of DC microgrid compared to the conventional AC grid. The components in the microgrid have diverse features, so there is need of proper coordination control. For achieving economic feature, the active power of renewable energy resources is regarded as major control parameter and the whole operation modes of DC microgrid are defined, and the proper operations of each component are described. From the inherent characteristics of DC, there are two control variables: voltage and active power. Through analysis of operation modes, it is possible to determine exact control objectives and optimized voltage & power control strategy in each mode. Because of consideration of whole operation modes, regardless of the number and capacity of components, this coordination control method can be used without modification. This paper defines operation mode of DC microgrid with several DC sources and suggests economic and efficient coordinated control methods. Simulation with PSCAD proves effectiveness.

선삭에서 절삭 속도 제어를 통한 표면 거칠기 향상 (Improvement of Surface Roughness by the Cutting Speed Control for Turning Operation)

  • 최종환
    • 한국기계가공학회지
    • /
    • 제7권2호
    • /
    • pp.23-30
    • /
    • 2008
  • As a basic machining process, turning is a widely used machining process in which a single-point cutting tool removes material from the surface of a rotating material. A common method of evaluating machining performance is to measure the surface roughness. In a turning operation, it is important to select cutting conditions for achieving high cutting performance. As a rule, cutting conditions can be classified into feed rate, depth of cut and insert radius. While cutting process even though cutting conditions are optimized, the average roughness can be deterioration due to wear of the cutting tool edge. In this study, the aim is to maintain the average roughness even though the cutting condition is irregularly changing within the predictable range due to the working environment. First, the surface roughness model influenced by cutting conditions is constructed based on the experimental results in a turning operation, Second, applying the sliding mode control theory to the turning operation model which is composed of the surface roughness model and the motor transfer function, the surface roughness is closed to the desired value. Finally, the effectiveness of this approach is demonstrated through the computer simulation.

  • PDF

마이크로터빈발전시스템 계통연계운전을 위한 동적 모델링 및 시뮬레이션 (Dynamic model and simulation of microturbine generation system for grid-connected operation)

  • 홍원표;조재훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.105-110
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of Power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF