• 제목/요약/키워드: Operation mode

검색결과 2,501건 처리시간 0.028초

무전극 램프에서의 히스테리시스와 모드 변환 (Hysteresis and Mode Transition in Electrodeless Fluorescent Lamp)

  • 이주호;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.453-453
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation: a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF

선형계획법에 의한 계통연계형 마이크로그리드의 최적 운용에 관한 연구 (Linear Programming based Optimal Scheduling for Grid-connected Microgrid)

  • 박재세
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1622-1626
    • /
    • 2011
  • Recently, interests on microgrids have been growing as clean power systems. Microgrids include small scaled distributed generation such as wind and solar power as well as diesel generators as main power sources. To operate a microgrid effectively, optimal scheduling for the microgrid is important. Especially, in the grid-connected mode, power trades between the microgrid and the power grid should be considered in optimal scheduling. In this paper, mathematic models for optimal operation of a microgrid were established based on the linear programming. In particular, the shiftable load was considered in the models to optimize it in microgrid operation. To show feasibility of the proposed models, they were applied to optimal microgrid operation and the results were discussed.

도시철도의 급행운전 시행방안 연구 (A Study on Implementation of rapid service in urban railway (In Seoul Metropolitan area))

  • 후지타 다카요시;노혁재;김경철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.501-506
    • /
    • 2004
  • This paper aims to suggest the feasibility of rapid operation scheme generated in preceding study, 'A study on development of operation planning for rapid service in urban railway(An introduction)' through application it to present subway lines in Seoul Metropolitan area. In case of line 3, without the Passing Track 'Turning train outstrip mode' is the best policy. In case of line 4, with the Passing Trank 'Passing track mode' may be the best way to realize the this scheme. Also, there is feasibility in the line 1, line 5, line 6, line 7 but there is no possibility it is applied to line 2 and line 8. In conclusion, this paper is intend to suggest the possibility of rapid operation in urban railway by presenting real operation scheme, time tables and amount of power usage and the number of composing trains and variety of demand,

  • PDF

열병합발적용 Dual Fuel Engine의 질소산화물 배출저감에 관한 연구 (A Study on the Reduction of $NO_x$ Emission from Dual Fuel Engine for Co-generation System)

  • 정일래;김용술;심용식
    • 한국대기환경학회지
    • /
    • 제7권1호
    • /
    • pp.31-40
    • /
    • 1991
  • This study shows the correlation between $NO_x$ emission in the exhaust gas and various operation factors of dual fuel engine for Co-generation system. General tendency was shown that the thermal efficiency was lowered by the change of operation factors. However these were not confirmed on this experiment. Increasing T4 temperature (exhaust gas temperature at turbo-charger inlet) reduces $NO_x$ emission rate. The higher T4 temperature requires lower excess air as the excess air ratio is controlled by T4 temperature on gas mode operation. Another tendency was that $NO_x$ emission rate is reduced in case of increasing boost air temperature, quantity of pilot oil or bypassing flue gas through the exhaust gas boiler. The diameter of the fuel injection nozzle was changed smaller than design value and the injection timing was readjusted. Thus $NO_x$ emission rate could be reduced as retarding injection timing and changing hole diameter of fuel injection nozzle, however maxium engine out-put was decreased by changing fuel nozzle on the diesel mode operation.

  • PDF

A Study of contact Detection and Position Sensitivity of AE Sensor

  • Kwon, Haesung;Choa, Sung-Hoon
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.29-33
    • /
    • 2000
  • In this study, a methodology is developed and confirmed to find the physical contact between the slider and disc due to the defects of disk during head seeking operation using acoustic emission (AE) signal. The head/disk contact was detected during random and standard seeks, whereas no contact was detected during track fellowing. During standard and random seeks, the torsion mode of slider excitation was observed at 680KHz. Therefore, it is thought that AE technique can be used as an alternative method of the glide test by monitoring existence of the torsional mode of the slider during seek operation or can be used to detect the spacing loss during seeking operation. By appropriately choosing the location of the sensor an order of magnitude increase in the sensitivity for RMS AE signal is observed. Therefore we can find take-off velocity clearly with high signal to noise ratio of AE signal.

  • PDF

Sag와 Swell에 따른 계통 이상 검출에 관한 연구 (The Study of Grid Fault Detection for Sag, Swell)

  • 김민기;노용수;김준구;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

마이크로터빈발전시스템 독립운전을 위한 동적 모델링 및 시뮬레이션 (Dynamic model and simulation of microturbine generation system for islanding mode operation)

  • 홍원표;조재훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.453-457
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market. In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for isolated operation. The system comprises of a Permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in islanding operation mode of a DG system.

  • PDF

배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가 (Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage)

  • 김현준;김도현;김경태;한병문
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

전류 컷 기법을 적용한 저전력형 직병렬/병직렬 변환기 설계 (Design of Low-power Serial-to-Parallel and Parallel-to-Serial Converter using Current-cut method)

  • 박용운;황성호;차재상;양충모;김성권
    • 한국통신학회논문지
    • /
    • 제34권10A호
    • /
    • pp.776-783
    • /
    • 2009
  • 본 논문에서는 OFDM과 같은 대용량 무선 전송방식의 베이스밴드단(Baseband) 신호처리 방식 중 직병렬/병직렬 변환기(Serial-to-Parallel/Parallel-to-Serial Converter)를 전류모드(Current-mode) 회로로 구현했을 경우 유효한 설계 기법을 제안한다. 전류모드를 이용한 OFDM(Orthogonal Frequency Division Multiplexing: 직교주파수분할다중)용 아날로그 프리에 변환(FFT) LSI의 병렬 입출력을 담당하는 전류모드 직병렬병직렬 변환기의 홀드모드(Hold mode)의 불필요한 전류를 제거할 수 있다. 이를 통해 전류모드로 구성한 아날로그 신호처리 시스템의 저소비전력을 실현하기 위해 필수적인 새로운 전류모드 직병렬/병직렬 변환기를 제시하고 설계된 칩의 측정결과가 시뮬레이션 결과와 일치하는 것을 확인하였다. 이를 통해 저전력형 대용량 무선통신 시스템의 베이스밴드단 구축이 가능한 전류모드 아날로그 시스템의 구현 가능성을 제시하였다.