• 제목/요약/키워드: Operation margin

검색결과 402건 처리시간 0.023초

High-fidelity numerical investigation on structural integrity of SFR fuel cladding during design basis events

  • Seo-Yoon Choi;Hyung-Kyu Kim;Min-Seop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.359-374
    • /
    • 2024
  • A high-fidelity numerical analysis methodology was proposed for evaluating the fuel rod cladding integrity of a Prototype Gen IV Sodium Fast Reactor (PGSFR) during normal operation and Design basis events (DBEs). The MARS-LMR code, system transient safety analysis code, was applied to analyze the DBEs. The results of the MARS-LMR code were used as boundary condition for a 3D computational fluid dynamics (CFD) analysis. The peak temperatures considering HCFs satisfied the cladding temperature limit. The temperature and pressure distributions were calculated by ANSYS CFX code, and applied to structural analysis. Structural analysis was performed using ANSYS Mechanical code. The seismic reactivity insertion SSE accident among DBEs had the highest peak cladding temperature and the maximum stress, as the value of 87 MPa. The fuel cladding had over 40 % safety margin, and the strain was below the strain limit. Deformation behavior was elucidated for providing relative coordinate data on each active fuel rod center. Bending deformation resulted in a flower shape, and bowing bundle did not interact with the duct of fuel assemblies. Fuel rod maximum expansion was generated with highest stress. Therefore, it was concluded that the fuel rod cladding of the PGSFR has sufficient structural safety margin during DBEs.

악성 말초신경막 종양의 치료와 생존율 (Treatment and Survial Rate of Malignant Peripheral Nerve Sheath Tumors)

  • 이종석;전대근;조완형;이수용;오정문;김진욱
    • 대한골관절종양학회지
    • /
    • 제9권2호
    • /
    • pp.131-138
    • /
    • 2003
  • 서론: 악성 말초 신경막 종양(Malignant peripheral nerve sheath tumor, MPNST)에 대하여 수술, 항암제 투여, 방사선 치료 등을 시행하고 이에 따른 종양학적 결과를 분석하여 보다 합리적인 치료 방법을 알아보고자 하였다. 재료 및 방법: 1986년 2월부터 1996년 11월까지 본원에 등록된 MPNST 환자 34례를 대상으로 하였다. 남자가 17례, 여자가 17례였고 평균연령은 41세(18세~74세)였다. 종양의 위치는 하지가 17례, 상지 11례, 체간부 4례, 후복막 2례였다. AJC(American Joint Committee on Cancer) 분류에 의한 종양의 병기는 stage IA가 2례, stage IIA 2례, stage IIB 6례, stage III 16례, 그리고 stage IV가 8례였다. 치료 방법으로는 26례에서 수술과 항암제 투여 그리고 때에 따라서 방사선치료를 시행하였고 3례에서는 수술만, 3례에서는 항암제 투여나 방사선 치료만 시행하였다. 평균 추시 기간은 33.5개월(5.6개월~141.1개월)이었다. Kaplan-Meiyer 법으로 생존율을 구하였고, log rank test로 비교 분석 하였다. 결과: 최종 추시상 질병 상태는 14례에서 CDF(continuous disease free)였고, 2례가 NED(no evidence of disease), 2례 AWD(alive with disease), 그리고 14례가 DOD(died of disease)였다. 실제(actuarial) 5년 생존율과 10년 생존율 은 53.5 %와, 35.7%였다. 수술 후의 국소 재발율은 24.1%였다. 병기별 5년 실질 생존율은 stage I이 100%, stage II 85.7%, stage III 55.9%였고 stage IV의 경우 2년 실질 생존율이 14.3%였다(p=0.04). Stage II, III에서 수술한 경우 21례에서, 광범위 이상의 절제연을 얻었던 경우가 15례로 5년 실질생존율이 76.0%였고 병소내이거나 변연부 절제연의 경우는 6례로 40.0%였다(p=0.26). 4회차 이상의 항암화학요법제를 투여한 군(8례)의 5년 실질생존율은 71.4%였고 3회차 이하의 불충분한 항암제투여를 시행한 군(6례)의 3년 실질생존율은 83.3%였다(p=0.96). Stage II, III 중 방사선 치료 없이 수술 받은 19례에서 병소내 절제나 변연부 절제를 시행했던 5례는 3례가 국소 재발하였고(60.0%) 광범위 절제를 시행한 14례는 4례가 국소 재발하였다(28.6%). 수술 전 또는 후에 방사선치료를 시행하였던 8례에서는 국소재발이한 예도 없었다. 결론: 외과적 절제연(surgical margin)이 국소 재발에는 중요한 요인이었고, 통계적으로 의미있는 수치는 아니었지만 생존율에도 영향을 주는 경향이 있는 것으로 생각된다. 기존의 항암제 투여는 국소 재발이나 생존율상에 통계적으로 의미있는 차이를 보이지 못하였다. 수술전과 수술후 시행하였던 방사선치료는 국소 재발을 줄이는데 어느 정도의 효과를 보였다.

  • PDF

Ergonomic Analysis of Tele-operation Tasks and Remote Handling Devices for a Pyroprocessing Facility

  • Yu, Seung Nam;Lee, Jong Kwang;Kim, Sung Hyun;Park, Byung Suk;Kim, Ki Ho;Cho, Il Je
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.17-26
    • /
    • 2013
  • Objective: The aim of this study is ergonomic analysis of tele-operation tasks using modified remote handling devices dedicated to the cell of PRIDE(PyRoprocess Integrated inactive DEmonstration facility) in KAERI(Korea Atomic Energy Research Institute). Background: Tele-operation manipulators of the PRIDE are applied to perform the remote handling and management of pyroprocessing facilities. Generally, these kinds of systems are composed of master-slave system and its peripherals installed along a wall or ceiling of the cell, and the manipulators transmit the user's own motion to grippers directly. However, a user convenience and intuitiveness while operating the manipulators have not been fully considered in research fields. Method: This study tries to analyze the ergonomic performance of remote handling manipulators in the developed cell facility. It was included that the analysis of operator's capability for his/her own motion range of upper arm while manipulating the MSM, considerations of its manipulation margin and related tool modifications to improve the remote handling performance. Conclusion: The test results of several remote handling tasks performed in PRIDE are represented, and adequate operation strategies for the tele-operation system of hot-cell type facilities are proposed. Application: The knowledge represented in this study can be utilized to improve a tele-operation system operated in a large-scale hot-cell system.

HTGR PROJECTS IN CHINA

  • Wu, Zongxin;Yu, Suyuan
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.103-110
    • /
    • 2007
  • The High Temperature Gas-cooled Reactor (HTGR) possesses inherent safety features and is recognized as a representative advanced nuclear system for the future. Based on the success of the HTR-10, the long-time operation test and safety demonstration tests were carried out. The long-time operation test verifies that the operation procedure and control method are appropriate for the HTR-10 and the safety demonstration test shows that the HTR-10 possesses inherent safety features with a great margin. Meanwhile, two new projects have been recently launched to further develop HTGR technology. One is a prototype modular plant, denoted as HTR-PM, to demonstrate the commercial capability of the HTGR power plant. The HTR-PM is designed as $2{\times}250$ MWt, pebble bed core with a steam turbine generator that serves as an energy conversion system. The other is a gas turbine generator system coupled with the HTR-10, denoted as HTR-10GT, built to demonstrate the feasibility of the HTGR gas turbine technology. The gas turbine generator system is designed in a single shaft configuration supported by active magnetic bearings (AMB). The HTR-10GT project is now in the stage of engineering design and component fabrication. R&D on the helium turbocompressor, a key component, and the key technology of AMB are in progress.

우리나라 전력계통의 물리적 및 운영 측면에서의 공급 여유력 평가 (Physical and Operational Supply Margin Evaluation of KOREA Power System)

  • 권중지;정상헌;사박;트란트룽틴;최재석;차준민;윤용태
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.18-27
    • /
    • 2007
  • Successful operation of power system under regulated as well as deregulated electricity markets is very important. This paper presents marginal power flow evaluation of KEPCO system in view point of physical and operation mode by using Physical and Operational Margins (POM Ver.2.2), which is developed by V&R Energy System Research. This paper introduces feature and operation mode of POM Ver.2.2 and then evaluates scenarios of 6 lines contingencies of 765kv of KEPCO system at peak load time on summer in 2006 you. The case study for actual 2006 year KEPCO system shows that this POM program is applicable sufficiently to KEPCO system. Futhermore, it demonstrates that it is helpful for operator's operating the system successfully by evaluating physical and operational margins quickly for various contingencies occurred in KEPCO system. Eventually, it will assist operators to operate more reliably the KEPCO system in future.

매입형 영구자석 동기전동기의 약계자 제어를 위한 최대전압 선정에 관한 연구 (Study of the Method of Calculating Maximum Voltage for Flux-Weakening Operation of Interior Permanent Magnet Synchronous Motor)

  • 김장목;김수열;류호선;안용호;윤기갑;임익헌;전향식
    • 한국안전학회지
    • /
    • 제15권2호
    • /
    • pp.63-69
    • /
    • 2000
  • The constraint conditions are the stator voltage and the stator current to operate the motor in the flux weakening region. The maximum current is limited by the inverter current rating and the machine thermal rating. Given DC link voltage to control the motor in the flux weakening the maximum voltage is determined by considering PWM strategy, dead time, voltage drop of the inverter switching device, and the margin of the voltage for current forcing. In this paper, the new method to determine the available maximum voltage is derived by the quantitative method and by considering the factors of the voltage drop. The proposed method to determine the maximum voltage is very useful to improve the stability of the motor system and to enlarge the speed operation region in the flux weakening operation. Therefore the utility of the maximum voltage is increased.

  • PDF

원발성간암(原發性肝癌) 1례(例)의 초음파진단(超音液診斷) (Ultrasonographic Findings in a Case of Primary Hepatoma)

  • 문수형;김강석
    • 보험의학회지
    • /
    • 제3권1호
    • /
    • pp.233-244
    • /
    • 1986
  • We'd experienced a case of primary hepatoma at medical department, Dae han Kyoyuk Ins. Company January 1985. As it was found very early stage, we made out the case long term-survival possibility unexpectedly. The conclusions we gained, making comparative-analysis of ultrasonic view and operation's view are as follows; 1. By ultrasonography, echogenicity of tumor was increased type as compared with liver parenchyme. 2. The margin of the primary hepatoma by ultrasonography encapsulated well and the extraction after operation was same. 3. The boundary of tumor was clear. 4. The space-occupying lesion in liver was solitary. 5. The affected site was left lobe of the liver. 6. We couldn't discover a little fluid echo in upper abdomen on the ultrasonography, but could see in the cul-de-sac area and it accorded with the gross finding during laparotomy. 7. The case was cholangiocarcinoma in view of pathologic histology. 8. After the operation of lobectomy. the prognosis which was passed a months was very satisfactory and she exists until present.

  • PDF

Loss of Coolant Accident Analysis During Shutdown Operation of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.17-28
    • /
    • 1999
  • A thermal-hydraulic analysis is conducted on the loss-of-coolant-accident (LOCA) during shutdown operation of YGN Units 3/4. Based on the review of plant-specific characteristics of YGN Units 3/4 in design and operation, a set of analysis cases is determined, and predicted by the RELAP5/MOD3.2 code during LOCA in the hot-standby mode. The evaluated thermal-hydraulic phenomena are blowdown, break flow, inventory distribution, natural circulation, and core thermal response. The difference in thermal-hydraulic behavior of LOCA at shutolown condition from that of LOCA at full power is identified as depressurization rate, the delay in peak natural circulation timing and the loop seal clearing (LSC) timing. In addition, the effect of high pressure safety injection (HPSI) on plant response is also evaluated. The break spectrum analysis shows that the critical break size can be between 1% to 2% of cold leg area, and that the available operator action time for the Sl actuation and the margin in the peak clad temperature (PCT) could be reduced when considering uncertainties of the present RELAP5 calculation.

  • PDF

연부조직 육종의 수술후 방사선치료 (Postoperative Radiation for Soft Tissue Sarcoma)

  • 박원종;장주해;강용구;송석환;문명상;김정만;우영균;이승구;김형민;김연실;장지영;윤세철
    • 대한골관절종양학회지
    • /
    • 제1권1호
    • /
    • pp.84-90
    • /
    • 1995
  • To evaluate the role of radiation and chemotherapy after limb-saving operation in the management of soft tissue sarcoma, the authors analysed retrospectively 33 patients treated in department of Orthoaepdic Surgery and Radiation Therapy, Catholic University Medical College, in terms of survival rate, local recurrence rate and prognostic factors. There were 16 males and 17 females. The age distribution ranged from 16 to 81 years with mean age of 48. The follow-up period ranged from 2 to 10 years with average of 5.5 years. The histologic diagnoses were 9 liposarcoma(27.2%), 8 malignant fibrohistiocytoma(24.2%), 7 unclassifiable(21.2%), 3 rhabdomyosarcoma(9.1%), 2 malignant schwannoma, 2 synovral sarcoma, and 2 fibrosarcoma(6.1%) in orders. While marginal and intralesional margins were gained in 24 patients(72.7%), wide and radical margins were obtained only in 9 patients(27.3%). On postoperative 3 weeks, local irradiation of 5000-7000 cGy was delivered to all patients by shrinking field technique for 5-8 weeks. Of 33 patients, 16(45.5%) patients were received adjuvant chemotherapy in combination of adriamycin, cyclophosphamide & vicristine, or VP16 & ifosfamide based on histologic type and obtained surgical margin. The survival rates by direct method at 2 years and 5 years were 58% and 37% respectively. Local recurrences occured in 15 patients(45.5%) at average 16 months after operation. Survival rates at 2 years and 5 years were 37% and 22% in case of intralesional and manginal excision, 75% and 47% in case of wide and radical excision respectively with statistical significance(p<0.05). They were 25% and 17% in the presence of local recurrence, 67% and 42% in the absence of local recurrence respectively with statistical significance(p<0.05). Even though there was no statistical correlation between survival rate and tumor size(p>0.05), the authors considered tumor size as a significant prognostic factors as well as surgical margin and the presence of local recurrence.

  • PDF

근위 경골 골육종의 부분 절제술 - 증례 보고 - (Partial Resection of Osteosarcoma in Proximal Tibia - A Case Report -)

  • 송원석;이승준;원호현;전대근
    • 대한골관절종양학회지
    • /
    • 제14권2호
    • /
    • pp.140-145
    • /
    • 2008
  • 사지 구제술이 보편화된 후 슬 관절 주위 골육종 환자의 재건 방법은 술자의 선호도에따라 차이가 있을 수 있으나 비교적 표준화 되어 있다. 현재 주로 시행되는 사지 구제술 방법으로는 크게 인공관절 치환술, 동종골 이식술이 있다. 인공관절 치환술의 경우 매우 안정적이며 술후 기능적으로도 양호한 방법으로 알려져 있으나, 궁극적으로 파손에 의한 제거술 시행이 필수적인 단점이 있다. 장기적인 관점에서 볼때 이식골을 이용한 재건술은 큰 장점을 갖고 있다. 하지만, 동종골의 사용은 요구되는 크기와 모양을 쉽게 구하기 어렵다는 단점이 있으며, 자가골 이식술은 수술 절제연이 안전하고, 그 적응증이 확립된 경우에만 사용해야 한다는 단점을 갖고 있다. 사지 구제술에 있어 분절 절제법은 골간의 병변에 있어 그 유용성이 확립되어 있으나, 골간단의 병변에 있어서는 시행 적응증이 널리 알려져 있지 않다. 저자들은 17세 환자의 근위 경골 내측과에 국한적으로 발생한 골육종의 증례에서 내측과 절제만으로도 안전한 절제연을 얻을 수 있을 것으로 사료되어 내측과 절제술 및 저온 열처리 자가골 이식술을 시행하였다. 본 술식은 추가적인 성장이 예상되는 소아환자에게 시행하였을 경우, 추후 파손 발생시에도 반측 치환술로 치환 가능한 방법으로 생각되어 보고하는 바이다.

  • PDF