• Title/Summary/Keyword: Operation layer

Search Result 1,096, Processing Time 0.031 seconds

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

A Basic Study on Site Selection of Ocean Thermal Energy Conversion Plant in Adjacent Seas of the Korean Peninsula (I) (한국근해 해양 온도차 발전소의 입지선정에 관한 기초연구 (I))

  • Suh, Young-Sang;Jang, Lee-Hyun;Jo, Myung-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.1 no.2
    • /
    • pp.44-55
    • /
    • 1998
  • This study was carried out to investigate the feasibility of OTEC(Ocean Thermal Energy Conversion) operation, in the East Sea of Korea. Accumulated cruise data of NFRDI (National Fisheries Research and Development Institute) over the period 1966~1995 were used to locate appropriate spot by season as well as by latitude which would show the difference at least $15^{\circ}C$ or more between the surface layer and each depth of 50, 100, 150, 200, 250, 300, 400 and 500m. Our results showed that the coastal areas of Pohang city met the requirement of more than $20^{\circ}C$ difference for OTEC plant from August to October. In contrast, in case that $15^{\circ}C$ would be possible thermal difference to operate OTEC plant, most coastal areas in the East Sea including Pohang from June to December are potential candidates for this future energy source. Therefore, we present in this paper the first option to locate the best place for OTEC plant operation using Geographical Information System (GIS), which is currently used for multi-dimensional space analysis.

  • PDF

Clinical Review about Corrective Surgery of Tetralogy of Fallot (팔로사징증의 근치 수술에 관한 임상적 고찰)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.674-684
    • /
    • 1991
  • The surgical treatment of tetralogy of Fallot [TOF] was initiated by Blalock and Taussig in 1945 with the establishment of the subclavian artery to pulmonary artery anastomosis. In an imaginative and daring effort, in 1954, Lillehei and collaborators [1955] using controlled cross-circulation, carried out the first intracardiac repair of TOF by closing the ventricular septal defect [VSD] and relieving the pulmonary stenosis under direct vision. Nowadays, total correction is the ideal operation for treatment of TOF and is accomplished with extracorporeal circulation. And the results of surgery for TOF have steadily improved over the years, thanks to important contributions of many surgeons. Nevertheless because of its protean physiologic and anatomic presentation, TOF continues to offer challenges to cardiologist and cardiac surgeons. Thirty two cases of TOF have undergone total corrective surgery using extracorporeal circulation in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, Inje University, from Oct. 1985 to Feb. 1990. Clinical considerations were applied to these cases and the results were obtained as follows. 1. The heart lung machine used for extracorporeal circulation was SarnsO 7000, 5-head roller pump, and the number and type of oxygenators were 10 of bubble type and 22 of membrane type. The mean bypass time was 148.9 minutes and the mean aortic cross clamp time was 123.8 minutes. The GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 2. 20 cases were male and 12 were female, the mean age was 8 years old and the mean body weight was 25Kg. 3. The preoperative symptoms were cyanosis [29 cases], squatting [27 cases] and etc. The mean values of preoperative Hb., Hct., and SaO2 were 16.5 gm /dl, 50.3%, and 78.5%. 4. Combined anomalies were noticed in 16 cases [50%]. Among them 10 cases were PFO and 6 cases were ASD. 5. The degree of aorta overriding were 25% in 5 cases, 25 ~ 50% in 22 cases and above 50% in 5 cases. The dPA/Ao [ratio of diameter of pulmonary artery trunk to ascending aorta] were below 25% in 5 cases, 25 ~ 50% in 10 cases, 50 ~ 70% in 6 cases and above 75% in 11 cases. 6. The types of RVOT [right ventricular outflow tract] stenosis were valvular and infundibular in 14 cases [43.6%], diffuse hypoplastic type in 12 cases [37.5%], infundibular in 5 cases, and valvular and supravalvular in 1 case. 7. One stage radical corrective surgery was applied to the all cases. In widening of the RVOT, 3 types of patches were used: MVOP [monocusp ventricular outflow patch, Polystan BioprosthesesO] in 3 cases, knitted Dacron vessel patches in 2 cases, and double layer with bovine pericardium and woven Dacron prosthesis in 26 cases. 8. Postoperative complications were occurred in 15 cases. Among them, low output syndrome were occurred in 10 cases [31.3%] and 2 of them were expired postoperatively.

  • PDF

The Implementation of Multi-Channel Audio Codec for Real-Time operation (실시간 처리를 위한 멀티채널 오디오 코덱의 구현)

  • Hong, Jin-Woo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.91-97
    • /
    • 1995
  • This paper describes the implementation of a multi-channel audio codec for HETV. This codec has the features of the 3/2-stereo plus low frequency enhancement, downward compatibility with the smaller number of channels, backward compatibility with the existing 2/0-stereo system(MPEG-1 audio), and multilingual capability. The encoder of this codec consists of 6-channel analog audio input part with the sampling rate of 48 kHz, 4-channel digital audio input part and three TMS320C40 /DSPs. The encoder implements multi-channel audio compression using a human perceptual psychoacoustic model, and has the bit rate reduction to 384 kbit/s without impairment of subjective quality. The decoder consists of 6-channel analog audio output part, 4-channel digital audio output part, and two TMS320C40 DSPs for a decoding procedure. The decoder analyzes the bit stream received with bit rate of 384 kbit/s from the encoder and reproduces the multi-channel audio signals for analog and digital outputs. The multi-processing of this audio codec using multiple DSPs is ensured by high speed transfer of date between DSPs through coordinating communication port activities with DMA coprocessors. Finally, some technical considerations are suggested to realize the problem of real-time operation, which are found out through the implementation of this codec using the MPEG-2 layer II sudio coding algorithm and the use of the hardware architecture with commercial multiple DSPs.

  • PDF

Functional Analysis of Electrode and Small Stack Operation in Solid Oxide Fuel Cell (고체산화물 연료전지의 전극과 스택운영의 기능적 분석)

  • Bae, Joong-Myeon;Kim, Ki-Hyun;Ji, Hyun-Jin;Kim, Jung-Hyun;Kang, In-Yong;Lim, Sung-Kwang;Yoo, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.812-822
    • /
    • 2006
  • This study amis to investigate the functional analysis of anode and cathode materials in Anode supported Solid Oxide Fuel Cell. The concentration polarization of single cell was investigated with CFD (Computational Fluid Dynamics) method for the case of the different morphology by using four types of unit cell and discussed to reduce the concentration polarization. The concentration polarization at anode side effected the voltage loss in Anode supported Solid Oxide Fuel Cell and increased contact areas between fuel gas and anode side could reduce the concentration polarization. For intermediate temperature operation, Anode-supported single cells with thin electrolyte layer of YSZ (Yttria-Stabilized Zirconia) were fabricated and short stacks were built and evaluated. We also developed diesel and methane autothermal reforming (ATR) reactors in order to provide fuels to SOFC stacks. Influences of the $H_2O/C$ (steam to carbon ratio), $O_2/C$ (oxygen to carbon ratio) and GHSV (Gas Hourly Space Velocity) on performances of stacks have been investigated. Performance of the stack operated with a diesel reformer was lower than with using hydrogen as a fuel due to lower Nernst voltage and carbon formation at anode side. The stack operated with a natural gas reformer showed similar performances as with using hydrogen. Effects of various reformer parameters such as $H_2O/C$ and $O_2/C$ were carefully investigated. It is found that $O_2/C$ is a sensitive parameter to control stack performance.

Simulation for the Estimation of Design Parameters in an Aquifer Thermal Energy Storage (ATES) Utilization System Model (대수층 축열 에너지(ATES) 활용 시스템 모델의 설계인자 추정을 위한 시뮬레이션)

  • Shim Byoung-Ohan
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.54-61
    • /
    • 2005
  • An aquifer thermal energy storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop the ATES system which has certain hydrogeological characteristics, understanding the thermohydraulic process of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermohydraulic transfer for heat storage was simulated according to two sets of simple pumping and waste water reinjection scenarios of groundwater heat pump system operation in a two-layered aquifer model. In the first set of the scenarios, the movement of the thermal front and groundwater level was simulated by changing the locations of injection and pumping wells in a seasonal cycle. However, in the second set the simulation was performed in the state of fixing the locations of pumping and injection wells. After 365 days simulation period, the shape of temperature distribution was highly dependent on the injected water temperature and the distance from the injection well. A small temperature change appeared on the surface compared to other simulated temperature distributions of 30 and 50 m depths. The porosity and groundwater flow characteristics of each layer sensitively affected the heat transfer. The groundwater levels and temperature changes in injection and pumping wells were monitored and the thermal interference between the wells was analyzed to test the effectiveness of the heat pump operation method applied.

Reconstruction of Congenital Absence of Vagina using Vulvoperineal Fasciocutaneous Flap: A Case Report (외음회음 근막피부피판을 이용한 선천성 질결여증의 재건례)

  • Kim, Mi-Sun;Kim, Chul-Han;Lee, Yong-Sek;Kang, Sang-Gue;Tark, Min-Sung
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.831-834
    • /
    • 2010
  • Purpose: Congenital absence of the vagina is a rare case. It occurs as a result of Mullerian duct aplasia or complete androgen insensitivity syndrome. The reconstructive modality includes skin graft, use of intestine and various methods of flap. We report a patient who underwent vulvoperineal fasciocutaneous flap to reconstruct congenital absence of the vagina, while the external genitalia and ovaries are normal. Methods: A 26-year-old woman presented with vaginal agenesis. Under general anesthesia, a U-shaped incision was made between the urethral meatus and the anus. The new vaginal pocket was created up to the level of the peritoneal reflection between the urinary structures and the rectum. Next, the vulvoperineal fasciocutaneous flaps were designed in a rectangular fashion. Flap elevation was begun at the lateral margin which the adductor longus fascia was incised and elevated, and the superficial perineal neurovascular pedicle was invested by the fascial layer. The medial border was then elevated. A subcutaneous tunnel was created beneath the inferior of the labia to rotate the flaps. The left vulvoperineal flap was rotated counterclockwise and the right was rotated clockwise. The neovaginal pouch was formed by approximating the medial and lateral borders. The tubed neovagina was then transposed into the cavity. Results: In 3 weeks, the vaginal canal remained supple After 6 weeks, the physical examination showed normalappearing labia majora and perineum with an adequate vaginal depth. A year after the operation, the patient had a 7 cm vagina of sufficient width with no evidence of contractures nor fibrous scar formation. The patient was sexually active without difficulty. Conclusion: Although many methods were described for reconstruction of vaginal absence, there is not a method yet to be approved as a perfect solution. We used the vulvoperineal fasciocutaneous flap to reconstruct a neovagina. This method had a following merits: a single-stage procedure, excellent flap reliability, the potential for normal function, minimal donor site morbidity and no need for subsequent dilatation, stents, or obturators. We thought that this operation has a good anatomic and functional results for reconstruction of the vagina.

Clogging Potential in Constructed Vertical Flow Wetlands Employing Different Filter Materials for First-flush Urban Stormwater Runoff Treatment (도시 초기 강우유출수 처리를 위한 수직흐름습지에서 여재별 폐색 잠재성 분석)

  • Chen, Yaoping;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • The function of vertical subsurface flow wetlands can potentially be reduced with time due to clogging and are often assumed to be occurring when ponding and overflow is observed during rainfall. To investigate their clogging potential, three pilot-scale vertical subsurface flow (VSF) wetland systems were constructed employing woodchip, pumice, and volcanic gravel as main media. The systems received stormwater runoff from a highway bridge for seven months, after which the media were taken out and divided into layers to determine the amount and characteristics of the accumulated clogging matters. Findings revealed that the main clogging mechanism was the deposition of suspended solids. This is followed by the growth of biofilm in the media which is more evident in the wetland employing woodchip. Up to more than 30% of the clogging matter were found in the upper 20 cm of the media suggesting that this layer will need replacement once clogging occurs. Moreover, no signs of clogging were observed in all the wetlands during the operation period even though an estimation of at least 2 months without clogging was calculated. This was attributed to the intermittent loading mode of operation that gave way for the decomposition of organic matters during the resting period and potentially restored the pore volume.

Comparative Analysis of the CALPUFF and AERMOD Atmospheric Dispersion Models for Ready-Mixed Concrete Manufacturing Facilities Generating Particulate Matter (미세먼지 발생 레미콘시설에서의 대기확산모델 CALPUFF와 AERMOD 비교 분석)

  • Han, Jin-hee;Kim, Younghee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.3
    • /
    • pp.267-278
    • /
    • 2021
  • Objectives: Using atmospheric dispersion representative models (AERMOD and CALPUFF), the emissions characteristics of each model were compared and analyzed in ready-mixed concrete manufacturing facilities that generate a large amount of particulate matter (PM-10, PM-2.5). Methods: The target facilities were the ready-mixed concrete manufacturing facilities (Siheung RMC, Goyang RMC, Ganggin RMC) and modeling for each facility was performed by dividing it into construction and operation times. The predicted points for each target facility were selected as 8-12ea (Siheung RMC 10, Goyang RMC 8, and Gangjin RMC 12ea) based on an area within a two-kilometer radius of each project district. The terrain input data was SRTM-3 (January-December 2019). The meteorological input data was divided into surface weather and upper layer weather data, and weather data near the same facility as the target facility was used. The predicted results were presented as a 24-hour average concentration and an annual average concentration. Results: First, overall, CALPUFF showed a tendency to predict higher concentrations than AERMOD. Second, there was almost no difference in the concentration between the two models in non-complex terrain such as in mountainous areas, but in complex terrain, CALPUFF predicted higher concentrations than AERMOD. This is believed to be because CALPUFF better reflected topographic characteristics. Third, both CALPUFF and AERMOD predicted lower concentrations during operation (85.2-99.7%) than during construction, and annual average concentrations (76.4-99.9%) lower than those at 24 hours. Fourth, in the ready-mixed concrete manufacturing facility, PM-10 concentration (about 40 ㎍/m3) was predicted to be higher than PM-2.5 (about 24 ㎍/m3). Conclusions: In complex terrain such as mountainous areas, CALPUFF predicted higher concentrations than AERMOD, which is thought to be because CALPUFF better reflected topographic characteristics. In the future, it is recommended that CALPUFF be used in complex terrain and AERMOD be used in other areas to save modeling time. In a ready-mixed concrete facility, PM-10, which has a relatively large particle size, is generated more than PM-2.5 due to the raw materials used and manufacturing characteristics.

Indoor Temperature Analysis by Point According to Facility Operation of IoT-based Vertical Smart Farm (IoT 기반 수직형 스마트 팜의 설비운영에 따른 지점별 실내온도분석)

  • Kim, Handon;Jung, Mincheol;Oh, Donggeun;Cho, Hyunsang;Choi, Seun;Jang, Hyounseung;Kim, Jimin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.98-105
    • /
    • 2022
  • It is essential for vertical smart farms that artificially grow crops in an enclosed space to properly utilize air environment facilities to create an appropriate growth environment. However, domestic vertical smart farm companies are creating a growing environment by relying on empirical data rather than systematic methods. Using IoT to create a growing environment based on systematic and precise monitoring can increase crop production yield and maximize profitability. This study aims to construct a monitoring system using IoT and to analyze the cause by demonstrating the imbalance of temperature environment, which is a significant factor in crop cultivation. 1) The horizontal temperature distribution of the multi-layer shelf was measured with different operating methods of LED and air conditioner. As a result, there was a temperature difference of "up to 1.7℃" between the sensors. 2) As a result of measuring the vertical temperature distribution, the temperature difference was "up to 6.3℃". In order to reduce this temperature gap, a strategy for proper arrangement and operation of air conditioning equipment is required.