• Title/Summary/Keyword: Operation layer

Search Result 1,096, Processing Time 0.031 seconds

The Effect Where the Service Quality of Civil Expense Goes Mad to a Customer Satisfaction (민간경비 서비스 질이 고객만족에 미치는 영향)

  • Kim, Myung-Hyun;An, Hwang-Kwon;Kim, Jong-lyur
    • Korean Security Journal
    • /
    • no.10
    • /
    • pp.35-52
    • /
    • 2005
  • This study is focused on the service quality and customer satisfaction. The survey on the service quality and customer satisfaction has the follows; First, man group compared to female group provision was receiving the service of good quality and also the customer satisfactory degree appeared highly. Also, the quality of the group one recording service where the age is many appeared customer satisfactory boat song highly. Second, the customer satisfaction regarding a high educational background one recording service quality did not appear highly and not to be with the thing recording where the educational background will be high provision to receive a more many serviceit is satisfied it appeared. It follows, consequently in member of society nine statistics quality and service quality of civil expense and the customer satisfaction is a difference and the recording customer where the service quality of civil expense will be high it goes round satisfactorily and there is possibility of saying that. Third, in service quality empathy characteristic of subordinate result, with the fact that static effect it will be going mad to a shedding of corporeal service satisfaction and a security facility satisfaction. The security facility satisfaction where the empathy characteristic and shedding of corporeal service quality will be good is high reflects a fact and it is giving. Fourth, market segment anger strategy and there is a necessity which will form the customer layer which is various. Also, the site for the service of good quality the operation of development and strategy elder brother system of the elder brother system which it fixes is necessary.

  • PDF

Arthroscopic Treatment of Recurrent Prepatellar Bursitis (관절경을 이용한 재발성 슬개골전 점액낭염의 치료)

  • Kyung Hee-Soo;Kim Hee-Soo;Hwang Jun-Kyung;Ihn Joo-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.183-187
    • /
    • 2002
  • Purpose : We report a result of arthroscopic treatment of the recurrent prepatellar bursitis. Materials and Methods : Between March 2001 and May 2002, we treated 4 patients with prepatellar bursitis, the average follow-up period was 14.5 months. The causes were acute trauma 3 cases and repeated minor trauma 1 case. All cases were recurred after previous history of the conservative therapy at other hospital but one was a recurred case after operative excision. Operative technique was as follows. Before inserting the arthroscope, the bursa was inflated with saline. The portals fur 4 mm diameter arthroscope were placed 1cm away from the bursal sac through small skin incision. Superficial layer of the bursa was resected first and then deep portion was the next. Several percutaneous mattress sutures were applied to the overlying skin with deep tissue, and compressive dressing was applied and maintained for 2 weeks. Results : All 4 cases were no recurrence, no pain, no tenderness. The results were considered satisfactory, Two cases of mild skin dimpling at suture site were observed. Conclusion : Arthroscopic treatment of the prepatellar bursitis is an another method of operation technique fur recurrent prepatellar bursitis, however long term follow-up will be needed about recurrence.

  • PDF

Fabrication of Small SOFC Stack Based on Anode-Supported Unit Cells and Its Power Generating Characteristics (음극지지형 단전지를 사용한 소형 SOFC 스택의 제조 및 출력특성)

  • Jung, Hwa-Young;Kim, Woo-Sik;Choi, Sun-Hee;Kim, Joosun;Lee, Hae-Weon;Ko, Haengjin;Lee, Ki-Chun;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.777-782
    • /
    • 2004
  • In this research, $5\times5cm^2$ unit cells were fabricated via liquid condensation process and uniaxial pressing followed by the screen printing of electrolyte and cathode layer. The SOFC stack was assembled with unit cells, gasket-type sealant and metal interconnect. The stack was designed to have a single column with internal-manifold and cross-flow type gas-channels. The SOFC stack produced 15 W, which is $50\%$ of the maximum power being expected from the maximum power density of the unit cell. Controlling factors for the proper operation of the SOFC stack and other designing factors of stack manifold and gas channels were discussed.

A study on electrical response property of photoconductor film for x-ray imaging sensor (X선 영상센서 적용을 위한 광도전체 필름의 전기적 응답특성 연구)

  • Kang, Sang-Sik;Kim, Chan-Wook;Lee, Mi-Hyun;Lee, Kwang-Ok;Moon, Yong-Soo;An, Sung-A;No, Ci-Chul;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.29-33
    • /
    • 2009
  • Recently, the compound materials(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$, etc.) that are used in flat panel x-ray imager have been studied for digital x-ray imaging. In this paper, the signal detection properties of $HgI_2$ and a-Se conversion layer, are compared. The thick $HgI_2$ film is fabricated by special particle-in-binder method and the conventional vacuum thermal evaporation is used for a deposition of a-Se film. And an electrical characteristic measurements were investigated about leakage current, signal response property and x-ray sensitivity. From the experimental results show that the $HgI_2$ film has a low operation voltage and high signal generation than that of a-Se.

  • PDF

Diagnosis of Water Environment and Assessment of Water Quality Restoration in Lake Shihwa (시화호의 수환경 진단과 수질회복 평가)

  • Kim, Dong-Seop;Go, Seok-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.5
    • /
    • pp.551-559
    • /
    • 2000
  • In order to diagnose the water environment and assess the water quality restoration, long term trend of water environment has been surveyed at 3-R stations from 1994 to 1999 in Lake Shihwa. Annual mean values of $COD_{Mn}$, Chlorophyll a, total nitrogen, total phosphorus and Secchi depth are ranged in 5.2-15.1 mg/L, 7.3-14R.1 jlg/L, 1.50-4.84 mgN/L, 0.055-0.281 mgP/L and 0.5 -1.4 m, respectively, during the study periods. Carson's trophic state indeies were varied from mesotrophy in 1994 and 1995, hyper-eutrophy in 1996 and 1997, to meso eutrophy in 199R and 1999. After dike construction, water quality were rapidly deteriorated by allochthonous and autochthonous loading of high nutrients and organic carbon. Eutrophication phenomena were characterized by massive phytoplankton blooms and high concentration of COD. However, after onset of restoration program, lake water quality was rapidly restored to the level of just after sea-dike construction. The diversion of waste water inflowing from the Panwol and the Sihwa industrial districts which was started from March, 1997 has contributed to improve water quality in the surface layer. And the tidal mixing (sea water inflowing) through the continuous gate operation was the most effective measure to the whole lake restoration.ration.

  • PDF

Discussion of Preliminary Design Review for MIRIS, the Main Payload of STSAT-3

  • Han, Won-Yong;Jin, Ho;Park, Jang-Hyun;Nam, Uk-Won;Yuk, In-Soo;Lee, Sung-Ho;Park, Young-Sik;Park, Sung-Jun;Lee, Dae-Hee;Ree, Chang-H.;Jeong, Woong-Seob;Moon, Bong-Kon;Cha, Sang-Mok;Cho, Seoung-Hyun;Rhee, Seung-Woo;Park, Jong-Oh;Lee, Seung-Heon;Lee, Hyung-Mok;Matsumoto, Toshio
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.27.1-27.1
    • /
    • 2008
  • KASI (Korea Astronomy and Space Science Institute) is developing a compact wide-field survey space telescope system, MIRIS (The Multi-purpose IR Imaging System) to be launched in 2010 as the main payload of the Korea Science and Technology Satellite 3. Through recent System Design Review (SDR) and Preliminary Design Review (PDR), most of the system design concept was reviewed and confirmed. The near IR imaging system adopted short F/2 optics for wide field low resolution observation at wavelength band 0.9~2.0 um minimizing the effect of attitude control system. The mechanical system is composed of a cover, baffle, optics, and detector system using a $256\times256$ Teledyne PICNIC FPA providing a $3.67\times3.67$ degree field of view with a pixel scale of 51.6 arcsec. We designed a support system to minimize heat transfer with Muti-Layer Insulation. The electronics of the MIRIS system is composed of 7 boards including DSP, control, SCIF. Particular attention is being paid to develop mission operation scenario for space observation to minimize IR background radiation from the Earth and Sun. The scientific purpose of MIRIS is to survey the Galactic plane in the emission line of Pa$\alpha$ ($1.88{\mu}m$) and to detect the cosmic infrared background (CIB) radiation. The CIB is being suspected to be originated from the first generation stars of the Universe and we will test this hypothesis by comparing the fluctuations in I (0.9~1.2 um) and H (1.2~2.0 um) bands to search the red shifted Lyman cutoff signature.

  • PDF

Simulation for application of pumping-and-treatment system to the recovery of non-aqueous phase liquids (NAPLs) at and below the water table (토양의 포화지대에 분포하는 고밀도비수상액체(DNAPL)와 저밀도비수상액체(LNAPL)의 펌핑 제거공정에 대한 모사)

  • 김주형;이종협
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.51-61
    • /
    • 1997
  • The objective of this study is to evaluate the feasibility of Pumping-and-Treatment system (PTS) for remediation of the saturated zones contaminated with NAPLs. A simulation is carried out for the removal of DNAPLs (denser-than-water non-aqueous phase liquids) and LNAPLS (lighter-than-water non-aqueous phase liquids) distributing at and below the water table. In the study, LNAPL and DNAPL are assumed to be n-hexane and 1,1-dichloroacetone, respectively. The model system studied consists of four heterogeneous soil layers with different permeabilities. Groundwater flows through the bottom layer and a pumping well is located under the initial water table. The time-driven deformation of the water table and removal efficiency of contaminants are estimated after vacuum application to the inlet of the well. In the calculation, FVM (Finite Volumetric Method) with SIMPLEC algorithm is applied. Results show that removal efficiencies of both DNAPL and LNAPL are negligible for the first 5 days after the PTS operation. However, when the cone-shape water table is formed around the inlet of the pumping well, the rapid removal rate is obtained since NAPLs migrate rapidly through the curvature of the water table. The removal efficiency of DNAPL is estimated to be higher than that of LNAPL due to the gravity. The results also show that the fluctuation or cone-shaped depression of the water table enhances the removal efficiency of NAPLs in saturated zones. The simulation results could provide a basis of the PTS design for the removal of NAPLs in saturated zones.

  • PDF

Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration (세라믹 막여과의 성능향상을 위한 응집 전처리의 적용)

  • Kang, Joon-Seok;Song, Jiyoung;Park, Seogyeong;Jeong, Ahyoung;Lee, Jeong-Jun;Seo, Inseok;Chae, Seonha;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

Development of Digital-Image-Correlation Technique for Detecting Internal Defects in Simulated Specimens of Wind Turbine Blades (풍력 블레이드 모의 시편의 내부 결함 검출을 위한 이미지 상관법 기술 개발)

  • Hong, Kyung Min;Park, Nak Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.5
    • /
    • pp.205-212
    • /
    • 2020
  • In the performance of a wind turbine system, the blades play a vital role. However, they are susceptible to damage arising from complex and irregular loading (which may even cause catastrophic collapse), and they are expensive to maintain. Therefore, it is very important both to find defects after blade manufacturing is completed and to find damage after the blade is used for a certain period of time. This study provides a new perspective for the detection of internal defects in glass-fiber- and carbon-fiber-reinforced panels, which are used as the main materials in wind turbine blades. A gap or fracture between fiber-reinforced materials, which may occur during blade manufacturing or operation, is simulated by drilling a hole 5 mm in diameter in the middle layer of the laminated material. Then, a digital-image-correlation (DIC) method is used to detect internal defects in the blade. Tensile load is applied to the fabricated specimen using a tensile tester, and the generated changes are recorded and analyzed with the DIC system. In the glass-fiber-reinforced laminated specimen, internal defects were detected from a strain value of 5% until the end of the experiment, while in the case of the carbon-fiber-reinforced laminated specimen, internal defects were detected from 1% onward. It was proved using the DIC system that the defect was detected as a certain level of strain difference developed around the internal defects, according to the material properties.

Unplanned Excision of Soft Tissue Sarcoma: Patient Profile and Treatment Outcomes (연부 조직 육종에 대한 무계획적 절제술: 환자의 임상적 특징 및 치료 결과)

  • Lee, Jae Hoo;Cho, Yong Jin;Kim, Seung Hyun;Shin, Kyoo Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.72-77
    • /
    • 2012
  • Purpose: Unplanned excision of a soft tissue sarcoma is defined as the operation performed for gross removal of a soft tissue sarcoma without regard for preoperative imaging or the necessity to removal a margin of normal tissue covering the cancer. We report our experience of treating primary soft tissue sarcoma after an unplanned excision. Materials and Methods: We retrospectively reviewed 31 patients referred to our hospital after unplanned excision at other hospitals for treatment of a STS. The clinical information was reviewed with a focus on the patient's age, gender, tumor location, tumor size, tumor depth, presumptive diagnoses at the previous surgery, refer hospital, definitive diagnosis, interval between the initial and additional surgery and local recurrence. Results: There were 19 males and 12 females with a median age of 48 years (range, 17-75 years) at the time of referral. Seventeen patients (54.8%) had tumors in their lower limb, 6 (19.4%) had tumors in their upper limb, and 8 (25.8%) had tumors in their trunk. Tumor depth could be determined for 8 patients (25.8%), with superficial and 22 deep tumors (71%). The medial interval between unplanned excision to re-excision ranged from 2 weeks to 1 year (median, 5 weeks). Local recurrence was detected in 2 patients. All patients were alive without metastasis at last follow up. Conclusion: Even in upper class general hospital, many unplanned excision had been performed, which is considered to be avoided. When the relatively huge mass located in deeper layer it requires enough preoperative imaging studies and biopsy.