• 제목/요약/키워드: Operation efficiency

검색결과 5,487건 처리시간 0.038초

300MW급 실증 가스화기의 최적 운전조건 및 성능 예측 (The Optimal Operation Condition and Estimation Performance for 300MW Demonstration Gasifier)

  • 유정석;구자형;백민수;이황직
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.368-371
    • /
    • 2008
  • The optimal operation condition of gasifier is one of the most important parameters to increase efficiency and reliability in IGCC plant. Also the prediction of the syngas composition and quantity must be predicted to carry out process design of the gasification plant. However, the gasifier process licensor are protective with information on process design and optimal gasifier design conditions. So, the most of process studies in the engineering company for gasification plant have carried out to look for key parameters and optimal design conditions using several prediction methods. In this paper, we present the estimated preliminary optimal operation condition of the 300MW Demonstration Entrain Flow Gasifier using Aspen Plus. The gasifier operation temperature considering slag flow was predicted by FactSage software and Annen Model.

  • PDF

영구자석 동기 서보 전동기의 제어에 관한 연구 (A study on Permanent Magnet Synchronous Servo Motor Control)

  • 김종구;최욱돈;정명길;이현상;김명찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.543-547
    • /
    • 1991
  • This paper illustrates maximum torque per ampare radio operation and efficiency operation, which are prevalently applied to the control of permanent magnet synchronous motor(PMSM). Maximum torque per ampare ratio operation minimizes the copper loss of PMSM and maximum efficiency operation minimizes the total loss of PMSM. To verify the difference of these method, simulation and experiment results applied to IPMSM(Interior type PMSM) and SPMSM(Surface mounted PMSM) are presented.

  • PDF

마이크로그리드의 효율적 운영을 위한 최적화기법의 응용 (An Application of Optimization method for Efficient Operation of Micro Grid)

  • 김규호
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.50-55
    • /
    • 2012
  • This paper presents an application of optimization method for efficient operation in micro grid. For operational efficiency, the objective function in a diesel generator consists of the fuel cost function similar to the cost functions used for the conventional fossil-fuel generating plants. The wind turbine generator is modeled by the characteristics of variable output. The cost function of fuel cell plant considers the efficiency of fuel cell. Particle swarm optimization(PSO) and sequential quadratic programming(SQP) are used for solving the problem of microgrid system operation. Also, from the results this paper presents the way to attend power markets which can buy and sell power from upper lever grids by connecting a various generation resources to micro grid.

Exploring the Appropriate Operation Ratio on Hospital Revenue Cost and Profit

  • Kim, Yang-Kyun;Sung, Joo-Ho;Kang, Jung-Chul
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권1호
    • /
    • pp.31-40
    • /
    • 2007
  • Many previous researchers tried to analysis relationship between financial index of hospitals such as revenue, expenses, and profit and hospital outcome such as number of inpatient and outpatient or, between that financial index and hospital size including number of hospital beds. However, these studies did not find exact relationship between financial index and hospital efficiency and productivity. Therefore, purpose of the study explores exact relationship between hospital financial outcome and hospital efficiency and productivity using adjusted inpatient days concept from American Hospital Association. Through the empirical analysis, the researchers find that hospital profit has the U-shape quadratic function to operation ratio. 66.9% of operation ratio is changing point and hospitals with 55.8% through 75.0% of operation ration have experience deficit situation. Considering the hospital circumstance, Korean hospitals would be to maintain general hospital type with various specialty departments.

  • PDF

철도에너지 효율화를 위한 운전자 지원시스템 적용방안 연구 (A study on application plan of driver assistance system for railway energy efficiency)

  • 김영규;박세영;고영호;남희복;한문섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.171-176
    • /
    • 2010
  • Railway has recently played an important role in preventing global warming caused by green house gases and furthering a low carbon green growth, The various railway research centers have conducted facilitated studies on saving energy. In particular, urban railway has emerged as the best means of public transportation in terms of punctuality, safety and environmentally friendliness. There are various ways to save energy in terms of operation of urban railway system, and they can be generally divided into hardware aspects that pertain to structure of vehicles and development of control system and software aspects that pertain to effective operation of trains based on operation patterns and diagram control. In this paper, we investigated drive assistance system for railway energy efficiency. The railway operation patterns and train diagram management programs were researched.

  • PDF

자율분산 역제어시스템의 효율성을 위한 자료분석 및 자료 활용방법에 관한 연구 (A study on material analysis and the usage for efficiency of the Autonomus Station Control System)

  • 하승태;안진;용성완
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.636-641
    • /
    • 2008
  • In this paper, the analysis methods of available information are reviewed and it is elicited to the method of which the analysis results are applied to the Autonomous Decentralized Train Management System for the optimization at the point of the route control time and for making the efficiency shunting plan in the Autonomous Centralized Station Operation Control System. As the statistics and estimated information which are got through the utilizable information analysis are applied for the automatic route control function and the shunting plan management of the station operation control system, it is possible to use efficiently the station information by the autonomous route control system. And as the exact forecast information needed for the shunting plan establishment and the operation is provided to the operator, it is established to the efficient train operation plan.

  • PDF

넓은 범위 입력전압에 소프트 스위칭이 가능한 양방향 인터리브드 DC-DC 컨버터 (Bidirectional Soft Switching Three-Phase Interleaved DC-DC Converter for a Wide Input Voltage Range)

  • 최우진;이교범;정규범
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.313-320
    • /
    • 2015
  • This study deals with a bidirectional interleaved soft switching DC-DC converter for a wide range of input voltages. The proposed converter operates in complementary switching with the purpose of inductor size reduction and zero-voltage switching (ZVS) operation. The current ripple related to complementary switching is minimized by three-phase interleaved operation. The main characteristics of the proposed topology are its soft-switching method of operation and its simple structure. The soft-switching operation and the system efficiency of the proposed converter are verified by experimental results.

도시철도 신호시스템 설계에서의 운전시격 향상에 대한 연구 (The Study of Headway Improvement on Signaling System Des19n of Urban Transit)

  • 백종현;안태기;정락교;한성호;변윤섭;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.492-494
    • /
    • 1999
  • To improve safety operation of urban transit, compatible design of signaling system is most important factor at future train operation and management. Therefore, signaling system should be designed compatible transport demand of target year. In addition, signaling system should be designed improved train safety, based fail-safe principle. Most of all, to solve passenger concentration, high density and to improve efficiency of train operation. Headway improvement of train is most important. Train organization length of new urban transit as light rail is generally shorter than EMU. Therefore, to increase passenger service and operation efficiency, minimum headway of one minute in this system should be important required.

  • PDF

고효율 산술연산기시스템 구성에 관한 연구 (A Study on Construction the Highly Efficiency Arithmetic Operation Unit Systems)

  • 박춘명
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.856-859
    • /
    • 2005
  • 본 논문에서는 Galois체에 기초를 둔 고효율 산술연산기 구성에 관한 한가지 방법을 제안하였다. 제안한 연산기는 기존의 방법에 비해 좀 더 규칙적이고 확장성이 용이한 이점이 있으며, 또한, 각종 멀티미디어 하드웨어 구성시의 기본인 연산기로 적용 및 응용할 수 있다. 향 후 연구과제로는 좀 더 콤팩트하고 효과적인 산술연산 알고리즘의 도출이 필요하며, 이에 논리 연산기를 접목하여 산술연산 및 논리연산을 수행하는 연산전용 프로세서의 개발이 필요하다.

  • PDF

다중권선 변압기를 이용한 능동형 셀 밸런싱 회로에서 밸런싱 전류 전달 효율을 높이기 위한 변압기 설계 방안 (Transformer Design Methodology to Improve Transfer Efficiency of Balancing Current in Active Cell Balancing Circuit using Multi-Winding Transformer)

  • 이상중;김명호;백주원;정지훈
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.247-255
    • /
    • 2018
  • This paper proposes a transformer design of a direct cell-to-cell active cell balancing circuit with a multi-winding transformer for battery management system (BMS) applications. The coupling coefficient of the multi-winding transformer and the output capacitance of MOSFETs significantly affect the balancing current transfer efficiency of the cell balancing operation. During the operation, the multi-winding transformer stores the energy charged in a specific source cell and subsequently transfers this energy to the target cell. However, the leakage inductance of the multi-winding transformer and the output capacitance of the MOSFET induce an abnormal energy transfer to the non-target cells, thereby degrading the transfer efficiency of the balancing current in each cell balancing operation. The impacts of the balancing current transfer efficiency deterioration are analyzed and a transformer design methodology that considers the coupling coefficient is proposed to enhance the transfer efficiency of the balancing current. The efficiency improvements resulting from the selection of an appropriate coupling coefficient are verified by conducting a simulation and experiment with a 1 W prototype cell balancing circuit.