• Title/Summary/Keyword: Operation Test

Search Result 5,205, Processing Time 0.032 seconds

Experimental Study of Automotive Gasolines in a Light Aircraft Engine (자동차용 가솔린의 경비행기 엔진 적합성에 관한 실험적 연구)

  • Sung, N.M.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.108-117
    • /
    • 1995
  • The primary purpose of this extensive test effort was to observe real-time operational performance characteristics associated with automotive grade fuel utilized by piston engine powered light aviation aircraft. In fulfillment of this effort, baseline engine operations were established with 100LL aviation grade fuel followed by four blends of automotive grade fuel. A comprehensive sea-level-static test cell/flight test data collection and evaluation effort were conducted to review operational characteristics of a carbureted light aircraft piston engine as related to fuel volatility, fuel temperature, and fuel system pressure. Presented herein are results, data, and conclusions drawn from test cell engine operation as well as flight test operation on 100LL aviation grade and four blends of automotive grade fuel.

  • PDF

Self-Testing for FFT processor with systolic array architecture (시스토릭 어레이 구조를 갖는 FFT 프로세서에 대한 Self-Testing)

  • Lee, J.K.;Kang, B.H.;Choi, B.I.;Shin, K.U.;Lee, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1503-1506
    • /
    • 1987
  • This paper proposes the self test method for 16 point FFT processor with systolic array architecture. To test efficiently and solve the increased hardware problems due to built-in self test, we change the normal registers into Linear Feedback Shift Registers(LFSR). LFSR can be served as a test pattern generator or a signature analyzer during self test operation, while LFSR a ordering register or a accumulator during normal operation. From the results of logic simulation for 16 point FFT processor by YSLOG, the total time is estimated in about. 21.4 [us].

  • PDF

5ft S-Band TT&C Antenna Test

  • Ahn Sang-il;Park Dong-Chul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.467-470
    • /
    • 2004
  • In early 2004, KARI developed 5ft S-Band TT&C antenna for especially KOMPSAT-2 operation in LEOP phase. This paper shows system features of 5ft S-Band antenna and its test result with KOMPSAT-l. Tracking test, command uplink test and telemetry downlink test were performed. Through tests, 5ft antenna was verified to be operational in uplink and downlink with KOMPSAT series. Due to its inherent wide 3dB beam-width of about 7deg at S-Band, this antenna system can be used very effectively even though orbital information is less accurate like LEOP and spacecraft safe mode.

  • PDF

Testing Harmonic Used Better than Aged in Expectation in Upper Tail(HUBAEUT) Class of Life Distributions Using Kernel Method

  • Abu-Youssef, S.E.;Al-nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • v.7 no.2
    • /
    • pp.89-99
    • /
    • 2006
  • A new classes of life distribution, namely harmonic used better than aged in expectation in upper tail (HUBAEUT) is introduced. Testing exponentiality against this class is investigated using kernel method. The limiting null and nonnull distribution of the test statistics is normal and the null variance is calculated exactly. Selected critical values are tabulated for sample sizes of 5(1)40. Power of the test are estimated by simulation. the efficacies of the test statistics used for testing against HUBAEUT are calculated for som common alternatives and are compared to some other procedures. It is shown that proposed test is simple, has high relative efficiency and power for some commonly used alternatives. The set of real data are used as an examples to elucidate the use of the proposed test statistics for practical reliability.

  • PDF

A Study of Inspection Module for Verifying Reliability on Railway Vehicle (철도차량 검측모듈의 신뢰성 검증 시험 연구)

  • Na, Kyung-min;Park, Young;Kwon, Sam-young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1155-1161
    • /
    • 2017
  • This study examines environmental performance of the arcing measurement module according to international standards. The module assesses the collected current performance using a computer system. The module is required to assess environmental impact resulting from electromagnetic waves, shock and temperature change during train operation. The test includes testing EMI/EMC, vibration, shock and temperature cycling for interface between trains and the arcing measurement module. The module test items were determined in compliance with the standards suggested by the International Electrotechnical Commission (IEC) and Europaische Norm (EN). This study describes the method of test, test equipment operation and how to choose relevant performance standards. The analysis and test results of environmental performance for the module based on computer system are described in this study.

Analysis and evalution of interior noise for Hanvit-200 train (한빛 200 열차의 실내 소음 특성 분석)

  • Lee, Chan-Woo;Kim, Jae-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1766-1769
    • /
    • 2008
  • INnterior noise characteristic of Korean tilting train(Hanvit 200) under the field test conditions is analyzed in this paper. The test railroad track was selected from Seodaejon to Songjeongri in Honam line. $4^{th}$ and $5^{th}$ car are decided to measure interior noise level among a train of six cars. The test subject open field executed from test sections. The speed of test trains when from existing operation speed and speed up 20% of existing speed. On open field at the time of operation speed of Hanvit 200 trains from below 160km/h interior noise level at $68dBA{\sim}70dBA$.

  • PDF

Development of Underwater ROV for Crack Inspection of River Facilities (하천 시설물 균열 검사를 위한 수중 ROV 개발)

  • Seong, Ho-Hwan;Lee, Jang-Myung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.4
    • /
    • pp.129-136
    • /
    • 2021
  • River facilities and port structures require a regular inspection and diagnosis due to obsolescence. Currently, most river facilities are undergoing indirect inspection and diagnosis by divers. The underwater inspections are not feasible due to safety issues of divers and restrictions on working hours and environment. To overcome these issues, it is intended to conduct inspections of river facilities using underwater drones. In this research, an underwater ROV (Remote Operated Vehicle) has been developed, which is a kind of drone with propellers. As a key device of this research, an injection device has been attached to the underwater drone to conduct an operation test, a stable operation test of an underwater drone, and a test of attached sensors. The river facility inspection can be carried out optimally using the hovering control of the drone and injection systems. With the developed ROV system, hovering test and injection test have been performed to verify the feasibility of this development.

Development of Interface Inspection System for On-board Signal Equipment (열차 차상신호 인터페이스 검사 시스템 개발)

  • Park, Jae-Young;Lim, In-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2324-2329
    • /
    • 2014
  • The inspection of distance to go train control system conducted only when train is in main line or inspecting line, that affects low work efficiency and hazard elements to safe operation. Before or after train operation, the interface test between on-board and wayside signal system must be conducted. In this paper, onboard signal interface inspection system based on the real-time automatic analysis of onboard system status information that is transmitted to the wayside system and the operation status check of the onboard signal device operates as a virtual train information that is transmitted to the onboard system have been proposed. And after building the inspection system to the inspecting track of Daejeon Subway Line 1, Panam Depot, the verification algorithm of proposed interface test and the results was presented. therefore, it has enhanced work efficiency to do not carry train operation of a half hour in test line to test on-board system.

Damage Pattern and Operation Characteristics of a Thermal Magnetic Type MCCB according to Thermal Stress (열동전자식 MCCB의 열적 스트레스에 따른 소손 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.69-73
    • /
    • 2013
  • The purpose of this paper is to analyze the carbonization pattern and operation characteristics of an MCCB. The MCCB is consisted of the actuator lever, actuator mechanism, bimetallic strip, contacts, up and down operator, arc divider or extinguisher, metal operation pin, terminal part, etc. When the actuator lever of the MCCB is at the top or the internal metal operation pin is in contact with the front part, the MCCB is turned on or off. It means trip state if the actuator lever or the internal metal operation pin moves to back side. In the UL 94 vertical combustion test, white smoke occurred from the MCCB when an average of 17~24 seconds elapsed after the MCCB was ignited and black smoke occurred when an average of 45~50 seconds elapsed. It took 5~6 minutes for the MCCB surface to be half burnt and took an average of 8~9 minutes for the MCCB surface to be entirely burnt. In the UL 94 test, the MCCB trip device operated when an average 7~8 minutes elapsed. If the MCCB trip has occurred, it may have been caused by an electrical problem such as a short-circuit, overcurrent, etc., as well as fire heat. From the entire part combustion test according to KS C 3004, it was found that the metal operation pin could be moved to the MCCB trip position without any electrical problems.

Risk Assessment for Abolition of Gross Containment Leak Monitoring System Test in CANDU Design Plant (중수로 원자로건물 총누설감시계통 시험 중지에 따른 리스크 영향 평가)

  • Bae, Yeon-Kyoung;Na, Jang-Hwan;Bahng, Ki-In
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.123-130
    • /
    • 2015
  • Wolsong Unit 2,3&4 has been performing a containment integrity test during power operation. This test could impact to the safe operation during test. If an accident occurs during pressure dropping phase, reactor trip can be delayed because of the increased pressure difference which causes a time delay to reach the trip set-point. On the contrary, if an accident occurs during pressure increasing phase, reactor trip could be accelerated because the pressure difference to the trip set-point decrease. Point Lepreau nuclear power plant, which installed GCLMS (Gross Containment Leakage Monitoring System) in 1990, has discontinued the test since 1992 due to these adverse effects. Therefore, we evaluated the risk to obviate the GCLMS test based on PWR's ILRT (Integrated Leak Rate Test) extension methodologies. The results demonstrate that risk increase rate is not high in case of performing only ILRT test at every 5 years instead of doing GCLMS test at every 1.5 years. In addition, the result shows that GCLMS test can be removed on a risk-informed perspective since risk increasement is in acceptable area of regulatory acceptance criteria.