• 제목/요약/키워드: Operation Condition

검색결과 4,090건 처리시간 0.028초

선재 가이드롤러 모니터링 시스템 개발 (The Development of Monitoring System for Guide Roller in Wire Rolling Process)

  • 손붕호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.671-673
    • /
    • 1999
  • In order to cope with the occurrence of abnormal operation, rotatory condition monitoring system for guide roller of finishing train in wire rolling has been developed. In this study, proximity sensor and its holding devices that could overcome severe in-situ measurement conditions was designed and MMI software using C++ was programmed. Performance of the developed system turned out to be good enough as results of in-line test for POSCO #3 wire rolling mill. It is expected to contribute to prevent the cobble and the grade-down of products caused by the abnornormal operation of guide rollers.

  • PDF

기계시각과 퍼지논리를 이용한 스피드스프레이어의 자율주행(I) -그래픽 시뮬레이션- (Autonomous SpeedSprayer Using Machine Vision and Fuzzy Logic (I) -Graphic Simulation-)

  • 조성인;기노훈
    • Journal of Biosystems Engineering
    • /
    • 제21권2호
    • /
    • pp.167-174
    • /
    • 1996
  • A Fuzzy Logic Controller(FLC) was developed for the autonomous operation of speedsprayer in an orchard. The autonomous operation with the FLC was graphically simulated under the real condition of the orchard. Image processing was used to find out the direction of running and four ultrasonic sensors were used to detect obstacles for the running. The simulation results showed that the speedsprayer could be operated autonomously with the FLC combined with the image processing and the ultrasonic sensors.

  • PDF

가변 동흡진기 구축을 위한 예비 실험 (Preparatory Experiment on the Construct ion of Tunable Dynamic Absorber)

  • 박종훈;한상보
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.329-334
    • /
    • 2002
  • Preliminary test for the design and construction of a tuned dynamic absorber is a conducted. Proposed tuned dynamic absorber is a cantilevered beam type, and is supposed to adjust its natural frequency according to the changing operation condition of the primary system. The modal mass of the dynamic absorber is the easiest to control, therefore, the position of the attached mass of the dynamic absorber is considered as the main design parameter of the absorber. The effect of the dynamic absorber is experimentally verified under various operation conditions of the primary system.

  • PDF

All-optical Regenerator Using Semi-reflective Semiconductor Optical Amplifier

  • Kim T.Y.;Kim J.Y.;Han S.K.
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.11-15
    • /
    • 2006
  • We have proposed and theoretically verified an optical regenerator using a single semi-reflective semiconductor optical amplifier (SR-SOA). To explain the operation characteristics and the operation condition of the proposed opticalregenerator, the simplified gain model for the SR-SOA is introduced and confirmed by comparing the result of the SOA simulation based on the transfer matrix method (TMM). The simulation results show that both extinction ratio (ER) enhancement and signal amplification can be achieved in the proposed regenerator.

보관작업장 사고방지 예방에 관한 연구: 렉 작업장을 중심으로 (A Study on Cargo Picking Safety Work: Focusing on Rack Work Place)

  • 정병현;김기홍
    • 대한안전경영과학회지
    • /
    • 제24권3호
    • /
    • pp.23-28
    • /
    • 2022
  • Rack is a place to store products. Workers pick products from rack storage. After picking up, workers move to another location by forklift. Driving speed, worker condition, and number/frequency of operation is responsible for forklift accidents. When an accident occurs, products get damaged. Therefore, it is important to prevent one. As the research result, To prevent forklift accidents, the minimum order quantity, the minimum number of operations, and low speed operation are required.

승용차의 부분부하제어를 위한 스크류형 과급기 개발 (Development of a Screw Type Super-Charger for Part Load Control of Passenger Car)

  • 배재일;배신철
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1427-1434
    • /
    • 2003
  • Turbo- or Super-charging has been used to boost engine power for Gasoline- and Diesel Engine since beginning of 20th century. So far turbo-charger has enjoyed a high reputation in the charging field for its technical advantages such as no demand of operation power from engine and an excellent charging effect in a static operation at mid- and high engine speed. A mechanically driven super-charger, however, is now popular due to the high engine power at quick change of the driving mode - high engine torque even at low engine speed. Since super-charger needs operation power from engine, it is difficult to improve its relatively higher fuel consumption than that of turbo-charger. This negative point is still an obstacle to the wide use of supercharger. Super-charger using screw-type compressor will fulfill the purpose to reduce fuel consumption by minimizing operation power owing to no charge at idling or part load driving condition. This study aims to develop power control concept to achieve the minimization of operation power. A screw type super-charger was modified in design partially and installed with an internal bypass valve and a bypass tube to control charging pressure at part load. The various control concepts show a possibility to reduce operation power of super-charger.

휴먼브릿지 치아보철 시술결과에 대한 고객만족도 분석 (Study On Customer Satisfaction of Dental Prosthetic Tooth Surgery by Human Bridge)

  • 김경진;조덕영
    • 보건의료산업학회지
    • /
    • 제4권1호
    • /
    • pp.11-22
    • /
    • 2010
  • The purpose of this study is to approving the usefulness on Customer Satisfaction of Human Bridge. To achieve this purpose, we conduct a survey of 385 Customer to have a new operation analysis that so-called Human Bridge. The results of this study as follow. First of all, It's appeared that dependence on mass communication has a high level Because that Some 66% of the people surveyed say that they have Human Bridge operation by mass communication. Secondly, In case of satisfaction level connected with operation, some 66% of the respondents say that it is inconvenient or not at all in the Human Bridge operation and some 81% of the respondents say that it is very healthy or the same in the gum condition. On the other hand, Some 64% of the people surveyed say that it is inconvenient or extra comfortable in the masticate their's food well. Thirdly, In case of the level of teeth shaking, Some 90% of the people surveyed say that it is no change or small to contrast beginning, and in aesthetic satisfaction after operation, a surprising 93% of the people surveyed say that it is satisfaction.

2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구 (A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance)

  • 이원석;정창호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.221-226
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

시흥정수장 막여과시설 시범운영 (A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant)

  • 김한승;김충환;김학철;윤재경;안효원
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Workshop
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF

2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구 (A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance)

  • 이원석;정창호;김진오
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.221-221
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.